0000000000784797

AUTHOR

Teresa Ferrer-blasco

showing 120 related works from this author

Clinical use of the ocular point spread function for retinal image quality assessment

2008

The purpose of this study is to demonstrate the clinical use of the point spread function (PSF) as metric for the assessment of retinal image quality in eyes with different ocular conditions. The PSF was computed from the wavefront aberrations obtained in seven eyes with different ocular conditions: emmetropia, myopia, hyperopia, post-myopic laser in situ keratomileusis (LASIK), post-hyperopic LASIK, keratoconus, Intacs ® in keratoconus, radial keratotomy (RK), LASIK after RK, cataract, phacoemulsification after cataract surgery, and LASIK after astigmatic keratotomy. The Strehl intensity ratio was calculated for all the PSFs computed. The PSF was correlated with the change in the optical e…

Point spread functionKeratoconusmedicine.medical_specialtygenetic structuresbusiness.industrymedicine.medical_treatmentBiomedical EngineeringEmmetropiaLASIKStrehl ratioKeratomileusismedicine.diseaseeye diseasesOphthalmologyRadial keratotomyRefractive surgeryOphthalmologyMedicineOptometrysense organsbusinessOptometryExpert Review of Ophthalmology
researchProduct

Amplitude, Latency, and Peak Velocity in Accommodation and Disaccommodation Dynamics

2017

The aim of this work was to ascertain whether there are differences in amplitude, latency, and peak velocity of accommodation and disaccommodation responses when different analysis strategies are used to compute them, such as fitting different functions to the responses or for smoothing them prior to computing the parameters. Accommodation and disaccommodation responses from four subjects to pulse changes in demand were recorded by means of aberrometry. Three different strategies were followed to analyze such responses: fitting an exponential function to the experimental data; fitting a Boltzmann sigmoid function to the data; and smoothing the data. Amplitude, latency, and peak velocity of …

AdultArticle Subjectlcsh:MedicineEyeRefraction Ocular050105 experimental psychologyGeneral Biochemistry Genetics and Molecular Biology03 medical and health sciences0302 clinical medicineReaction TimeHumans0501 psychology and cognitive sciencesLatency (engineering)MathematicsGeneral Immunology and MicrobiologyPulse (signal processing)business.industrylcsh:R05 social sciencesMathematical analysisWork (physics)Accommodation OcularGeneral MedicineSigmoid functionExponential functionAmplitude030221 ophthalmology & optometrybusinessAccommodationSmoothingResearch ArticleBioMed Research International
researchProduct

Evaluation of the iridocorneal angle with accommodation using optical coherence tomography

2017

The changes in the iridocorneal angle structure during accommodation are assessed by means of anterior segment optical coherence tomography. Thirteen right eyes were included in the study. The device used for the measurement was the Visante® omni system. The stimuli were set up at different vergences (0.0 D, -1.5 D, and -3.0 D). The angle opening distance 500 and 750, the trabecular iris space area 500 and 750, and the scleral spur angle parameters were assessed at the nasal and temporal regions. The results in the iridotrabecular angle comparing the three accommodative states of the eye did not yield any statistically significant difference at nasal or temporal angle sections. In light of …

accommodationmedicine.medical_specialtygenetic structuresiridocorneal angleScleral spuranterior segment03 medical and health sciences0302 clinical medicineOptical coherence tomographylcsh:OphthalmologyOphthalmologyMedicineIris (anatomy)Iridocorneal angleoptical coherence tomographymedicine.diagnostic_testbusiness.industryBrief ReportSignificant differenceOphthalmologymedicine.anatomical_structurelcsh:RE1-994Temporal Regions030221 ophthalmology & optometrysense organs1616businessAccommodation030217 neurology & neurosurgeryInternational Journal of Ophthalmology
researchProduct

Optical and visual quality comparison of implantable Collamer lens and laser in situ keratomileusis for myopia using an adaptive optics visual simula…

2012

Purpose. To compare optical and visual quality of the implantable Collamer lens (ICL) and laser in situ keratomileusis (LASIK) for myopia. Methods. An adaptive optics visual simulator (CRX1, Imagine Eyes, France) was used to simulate the vision after ICL implantation and LASIK procedure from the wavefront aberration pattern for -3 and -6 D. Monocular visual acuity (VA) at different contrasts and contrast sensitivity (CS) at 10, 20, and 25 cycles/degree (cpd) were measured for 3- and 5-mm pupils. Modulation transfer function (MTF) and point spread function (PSF) were calculated for a 5-mm pupil. Results. The ICL showed a MTF near of diffraction-limited MTF, but the post-LASIK of MTF worsened…

Point spread functionVisual acuityMaterials sciencemedicine.medical_treatmentLASIKKeratomileusisGeneral MedicinePupil03 medical and health sciencesOphthalmology0302 clinical medicineOptical transfer function030221 ophthalmology & optometrymedicineOptometrySpatial frequencymedicine.symptomAdaptive optics030217 neurology & neurosurgerySimulationEuropean journal of ophthalmology
researchProduct

Effect of Phenylephrine on the Accommodative System

2016

Accommodation is controlled by the action of the ciliary muscle and mediated primarily by parasympathetic input through postganglionic fibers that originate from neurons in the ciliary and pterygopalatine ganglia. During accommodation the pupil constricts to increase the depth of focus of the eye and improve retinal image quality. Researchers have traditionally faced the challenge of measuring the accommodative properties of the eye through a small pupil and thus have relied on pharmacological agents to dilate the pupil. Achieving pupil dilation (mydriasis) without affecting the accommodative ability of the eye (cycloplegia) could be useful in many clinical and research contexts. Phenylephr…

medicine.medical_specialtygenetic structuresReview ArticlePupil03 medical and health sciences0302 clinical medicinelcsh:OphthalmologymedicinePupillary responseMydriasisbusiness.industryCycloplegiaPhenylephrine Hydrochlorideeye diseasesSurgeryOphthalmologymedicine.anatomical_structureCiliary musclelcsh:RE1-994030221 ophthalmology & optometryOptometryHuman eyesense organsmedicine.symptombusinessAccommodation030217 neurology & neurosurgeryJournal of Ophthalmology
researchProduct

Accommodative Stimulus-Response Curve with Emoji Symbols

2017

Purpose. To evaluate the static measurement of the accommodative stimulus-response curve with emoji symbols. Methods. The accommodative stimulus-response curve was measured in 18 subjects using a Hartmann-Shack sensor to obtain the objective accommodative response from the Zernike defocus term. Measurements were acquired at different accommodative demands, from 0 to 3 D with a step of 0.5 D. Detailed and nondetailed emoji targets were used with two different sizes, corresponding to the two most common visual angles used in smartphones. Results. A regression analysis was performed to fit the mean results obtained for each target. The determination coefficient was R2≥0.988 for all targets. Fo…

Accommodative responseArticle SubjectZernike polynomialsEmojibusiness.industryRegression analysisPattern recognitionTerm (time)Stimulus response03 medical and health sciencesOphthalmologysymbols.namesake0302 clinical medicinelcsh:Ophthalmologylcsh:RE1-994030221 ophthalmology & optometrysymbolsMedicineComputer visionArtificial intelligencebusiness030217 neurology & neurosurgeryWord (computer architecture)Research ArticleJournal of Ophthalmology
researchProduct

Intraocular lens centration and stability: efficacy of current technique and technology

2008

Purpose of review The manuscript presents a review of recently published studies analyzing different methodologies to assess centration and stability of intraocular lenses after implantation. Recent findings Considering that there is no current gold standard for centration and stability of intraocular lenses after implantation, we have summarized the different techniques used clinically for intraocular lenses centration and stability estimation. We have described the use of Scheimpflug imaging, the anterior segment optical coherence tomography and photography analysis used for lens position estimation. Techniques used to assess lens rotation are based on image analysis on digital retroillum…

Rotationgenetic structuresmedicine.medical_treatmentScheimpflug principleImage processingIntraocular lenslaw.inventionLens Implantation IntraocularOptical coherence tomographyAnterior Eye SegmentlawImage Processing Computer-AssistedPhotographymedicineHumansLenses Intraocularmedicine.diagnostic_testbusiness.industryGeneral MedicineCentrationeye diseasesLens (optics)OphthalmologyIntraocular lensessense organsbusinessTomography Optical CoherenceBiomedical engineeringCurrent Opinion in Ophthalmology
researchProduct

Visual Comparison of an Artificial Pupil Contact Lens to Monovision

2012

PURPOSE To assess and compare the effects of contact-lens based artificial pupil design and monovision correction on visual performance. METHODS In a cross-over study design, 22 presbyopic patients (age range 50 to 64 years) were evaluated using artificial pupil contact lens on the non-dominant eye and monovision. After 1 month, binocular distance visual acuity (BDVA), binocular near visual acuity (BNVA), defocus curve, binocular distance contrast sensitivity, binocular near contrast sensitivity, and stereoacuity were measured, under photopic conditions (85 cd/m2), in each patient after contact lens fitting. Moreover, BDVA and binocular distance contrast sensitivity were examined under meso…

Malemedicine.medical_specialtyVisual acuitygenetic structuresContact LensesMesopic visionmedia_common.quotation_subjectVisual AcuityPupilVision MonocularOphthalmologymedicineHumansContrast (vision)media_commonMathematicsCross-Over StudiesPupilEquipment DesignPresbyopiaMiddle Agedeye diseasesContact lensStereoscopic acuityOphthalmologyTreatment OutcomeFemaleSpatial frequencymedicine.symptomFollow-Up StudiesOptometryPhotopic visionOptometry and Vision Science
researchProduct

Refractive lens exchange with a multifocal diffractive aspheric intraocular lens

2012

PURPOSE: To evaluate the safety, efficacy and predictability after refractive lens exchange with multifocal diffractive aspheric intraocular lens implantation. METHODS: Sixty eyes of 30 patients underwent bilateral implantation with AcrySof® ReSTOR® SN6AD3 intraocular lens with +4.00 D near addition. Patients were divided into myopic and hyperopic groups. Monocular best corrected visual acuity at distance and near and monocular uncorrected visual acuity at distance and near were measured before and 6 months postoperatively. RESULTS: After surgery, uncorrected visual acuity was 0.08 ± 0.15 and 0.11 ± 0.14 logMAR for the myopic and hyperopic groups, respectively (50% and 46.67% of patients ha…

MaleVisual acuitygenetic structuresDesenho de prótesesmedicine.medical_treatmentVisual AcuityEmmetropiaIntraocular lensProsthesis designMyopia/surgerylaw.inventionNear visionLens Implantation Intraocularlcsh:OphthalmologylawTonometry ocularMyopiaProspective StudiesLenses IntraocularLens crystalline/surgeryAcuidade visualGeneral MedicineMiddle AgedLens (optics)HyperopiaTreatment OutcomeFemalemedicine.symptomLens crystallinemedicine.medical_specialtyVisual acuityMiopiaRefractive lens exchangeProsthesis DesignStatistics NonparametricOphthalmologyLens CrystallinemedicineHumansHyperopia/physiopathologyHipermetropiaCristalinoAgedPhacoemulsificationbusiness.industryReproducibility of ResultsPhacoemulsificationPresbyopiamedicine.diseaseeye diseasesOphthalmologyLens implantation intraocularlcsh:RE1-994OptometryImplantação de lentes intraocularessense organsbusinessArquivos Brasileiros de Oftalmologia
researchProduct

Optical quality of hyperopic and myopic phakic intraocular lenses

2013

Aims: To assess and compare the optical quality of the myopic and hyperopic implantable collamer lens (ICL) from its wavefront aberrations for different powers and pupil diameters. Settings and Design: Prospective study. Material and Methods: The wavefront aberrations of two myopic (−3 and −6 diopters (D)) and two hyperopic V4b ICLs (+3 and +6D) were measured in vitro . To assess and compare the optical quality of different powers of ICLs, we analyzed the root mean square (RMS) of total higher order aberrations (HOAs), trefoil, coma, tetrafoil, secondary astigmatism, and spherical aberration at 3- and 4.5-mm pupil. In addition, the point spread functions (PSFs) of each ICL evaluated were ca…

steep corneal curvatureintravitreallacrimal fossaRefractive errorvisual acuitygenetic structurespterygium surgerystandard automated perimetryComa (optics)BlindnessPhakic intraocular lenslaw.inventionsubconjunctival bevacizumab injectionCorneaLens Implantation Intraocularlcsh:Ophthalmologylawmodified deep anterior lamellar keratoplastyMitomycin CMaterials TestingAutogenous tissue graftingProspective StudiesDioptreoptical qualityshort wave automated perimetryexcimer lasernon-proliferative diabetic retinopathyMean deviationin vitroheavy silicone oilBevacizumabLens (optics)Aberrations of the eyeSpherical aberrationHyperopiaAntimicrobial effectOriginal ArticleTriamcinolone acetonidehuman trabecular meshwork cellsPhakic Intraocular Lensesmedicine.medical_specialtyImaging in glaucomadisability evaluationconventional silicone oiltriamcinoloneProsthesis DesignKeratoconusphotorefractive keratectomyOphthalmologygrowth factorsmedicineHumansmyopiamyopic implantable collamer lensshort fluctuationsWavefrontmacular edemaoptical coherence tomographyendophthalmitis agentsbusiness.industrybranch retinal vein occlusionretinal nerve fiber layerpterygium recurrencemedicine.diseaseeye diseasesOphthalmologypediatricwavefront aberrationsquality of lifelcsh:RE1-994bypass surgeryHyperopic implantable collamer lenslacrimal drainage systemsense organsbusinessIndian Journal of Ophthalmology
researchProduct

The tear film and the optical quality of the eye

2010

The stability of the tear film plays an important role in the optical quality of the eye. Various methods have been developed to quantify the contribution of the tear film to optical quality, including the double-pass optical method, Hartmann-Shack wavefront sensing, videokeratoscopy, retroillumination analysis, and interferometry. In addition to assessing the effect of tear film irregularities, these methods can aid in the diagnosis of dry-eye related conditions and the monitoring of therapy. This review describes the methodologies used to assess the relationship between the tear film and optical quality of the eye and summarizes the most important findings obtained with these methods with…

Wavefrontmedicine.medical_specialtyCorneal Wavefront AberrationMaterials sciencegenetic structuresmedicine.medical_treatmenteye diseasesOptical qualityCorneaOphthalmologyInterferometryArtificial tearsmedicine.anatomical_structureTearsOphthalmologymedicineHumansOptometryDry Eye SyndromesHuman eyesense organs
researchProduct

Repeatability of in-vitro optical quality measurements of intraocular lenses with a deflectometry technique effect of the toricity

2018

Aim To evaluate the repeatability of an optical device for measuring the Zernike coefficients of toric intraocular lenses (IOLs) and assess whether its toricity has any impact in its repeatability. Methods An experienced technician used the NIMO TR1504 to measure the Zernike coefficients 30 times for an aperture of 4.50 mm for all lenses included. The IOLs included were divided into two group: toric and non-toric ones. The cylindrical powers of the toric lenses included in the present study were 1.00, 1.50, 2.25, 3.00 and 3.75 D. Finally, the repeatability of the NIMO TR1504 was described in terms of within subject standard deviation (Sw) and repeatability limit. Results The Sw was smaller …

1144ApertureZernike polynomialsmedicine.medical_treatmentintraocular lensIntraocular lensStandard deviationlaw.invention03 medical and health sciencessymbols.namesake0302 clinical medicineOpticslcsh:OphthalmologylawMedicinerepeatabilityoptical qualitybusiness.industryRepeatabilityOptical qualityToric lensLens (optics)Ophthalmologyin-vitro measurementslcsh:RE1-994030221 ophthalmology & optometrysymbolsbusiness030217 neurology & neurosurgeryInternational Journal of Ophthalmology
researchProduct

Avaliação por OCT in vivo do comprimentos axiais centrais do segmento anterior

2017

ABSTRACT Purpose: To assess changes in anatomic structures in the anterior eye segment in terms of axial lengths with accommodation via optical coherence tomography. Methods: In this observational study, 25 eyes of 25 healthy adults were examined using the Visante® omni optical coherence tomography system. Central corneal thickness, anterior chamber depth, central lens thickness, and anterior segment length were assessed. The evaluated parameters were obtained with accommodation using different stimulus vergences, namely 0.0, -1.0, -2.0, and -3.0 D. Variation of these parameters was compared among different levels of accommodation. Results: Central corneal thickness was not altered at any s…

AdultMalemedicine.medical_specialtySegmento anterior do olhoPosterior poleOcular physiologyYoung AdultOcular accommodationOptical coherence tomographyLens thicknesslcsh:OphthalmologyAnterior Eye SegmentOphthalmologymedicineHumansmedicine.diagnostic_testOptical coherence tomographybusiness.industrySegment lengthAccommodation OcularGeneral MedicineMiddle AgedAnterior eye segmentAnterior Eye SegmentOphthalmologylcsh:RE1-994Acomodação ocularTomografia de coerência ópticaFemaleTomographysense organsbusinessAccommodationTomography Optical Coherence
researchProduct

Optical and Visual Quality of the Visian Implantable Collamer Lens Using an Adaptive-Optics Visual Simulator

2013

To evaluate visual and optical quality of the implantable collamer lens for different powers and sizes of incision surgery.Prospective study in humans.An adaptive optics visual simulator was used to measure 3 powers of implantable collamer lenses and simulate the implantable collamer lens wavefront aberration's pattern for small- and large-incision surgery. Visual acuity (VA) and contrast sensitivity were measured in 11 observers for 3- and 5-mm pupils. Modulation transfer function, point spread function, and Strehl ratio were calculated.At 3 mm pupil, no statistically significant differences were found between both incision sizes for any implantable collamer lens power, except for -15 diop…

AdultMicrosurgeryOptics and PhotonicsPhakic Intraocular LensesVisual acuityAdolescentgenetic structuresComputer sciencemedia_common.quotation_subjectVisual AcuityPhakic intraocular lensPupilYoung AdultLens Implantation IntraocularOptical transfer functionmedicineHumansContrast (vision)Prospective StudiesAdaptive opticsVision OcularSimulationDioptremedia_commonAberrometryStrehl ratioeye diseasesRefractive Surgical ProceduresOphthalmologysense organsmedicine.symptomAmerican Journal of Ophthalmology
researchProduct

Accommodative Functions with Multifocal Contact Lenses: A Pilot Study

2011

PURPOSE: To evaluate accommodative response and facility in presbyopic patients fitted with several types of simultaneous-image multifocal contact lenses (CLs). METHODS: Six presbyopic patients, unadapted wearers of simultaneous-image bifocals, were fitted with the Focus Progressives and the low- and high-addition Pure Vision simultaneous vision multifocal CLs. Each individual wore each of the three types of lenses in successive random order. Accommodative response, accommodative facility, visual acuity, and contrast sensitivity at distance and near were evaluated in all cases. A control group of eight non-presbyopic patients was also studied. RESULTS: The mean age was 28.6 +/- 2.72 and 51.…

AdultMaleAccommodative responseDistance visual acuityVisual acuityContact Lensesmedia_common.quotation_subjectVisual AcuityPilot ProjectsContrast SensitivityNear visionHumansMedicineContrast (vision)media_commonbusiness.industryAccommodation OcularEquipment DesignPresbyopiaPresbyopiaMiddle AgedPrognosismedicine.diseaseOphthalmologyOptometryFemalemedicine.symptombusinessAccommodationMaximum amplitudeFollow-Up StudiesOptometryOptometry and Vision Science
researchProduct

Changes in accommodative responses with multifocal contact lenses: a pilot study.

2011

Our aim was to evaluate induced changes in pupil and accommodative response for different accommodative stimuli with three different multifocal contact lenses (CLs). Accommodative and pupil responses with three aspheric multifocal CLs of simultaneous focus center near (PureVision Low Add, PureVision High Add and Focus Progressives) for two accommodative stimuli of -2.5 and -4.00 D were recorded in 10 young subjects. Accommodative response, peak velocity, and time constant of accommodation and pupil constriction were assessed. The measurements were evaluated in all the participants with distance-single vision CLs and with the three multifocal CLs. The monocular measurements were performed in…

AdultMalemedicine.medical_specialtyAccommodative responsegenetic structuresContact LensesVisual AcuityPilot ProjectsRefraction OcularPupillaw.inventionOpticsCLs upper limitslawOphthalmologymedicineHumansMathematicsMonocularCross-Over Studiesbusiness.industryAccommodation OcularPupilPresbyopiaEquipment Designmedicine.diseaseRefractive Errorseye diseasesLens (optics)OphthalmologyTreatment OutcomePeak velocityOftalmologíaFemalebusinessAccommodationOptometryFollow-Up StudiesOptometry and vision science : official publication of the American Academy of Optometry
researchProduct

In vitro optical performance of a new aberration-free intraocular lens

2014

To assess the optical performance of the new EnVista intraocular lens (IOL). Four aspheric IOLs were evaluated; the new EnVista is one amoung them. This IOL, similarly to the Z-Flex HB and the Bi-Flex 1.8 667AB ones, has a neutral aspheric design, whereas the fourth IOL under test (AcrySof IQ IOL SN60WF) presents a negative spherical aberration (SA). The IOL’s aberration patterns were measured in vitro, by setting them up on an optical bench. From these aberration-pattern data, the modulation transfer function (MTF), the average modulation values, and the points spread function (PSF) were calculated. Furthermore, in order to assess the potential optical quality that these IOLs would yield o…

WavefrontLenses Intraocularmedicine.medical_specialtyOptics and PhotonicsMaterials scienceCorneal Wavefront Aberrationgenetic structuresmedicine.medical_treatmentIntraocular lensequipment and suppliesProsthesis Designeye diseasesOptical qualityOphthalmologySpherical aberrationmedicine.anatomical_structureCorneaOphthalmologyOptical transfer functionLaboratory StudymedicineProsthesis designHumanssense organsCorneal Wavefront Aberration
researchProduct

Medium-term visual, refractive, and intraocular stability after implantation of a posterior chamber phakic intraocular lens to correct moderate to hi…

2011

To evaluate the medium-term refractive and visual outcomes and the complications after implantation of a silicone posterior chamber phakic intraocular lens (PC pIOL) for moderate to high myopia.Oftalmar, Medimar International Hospital, Alicante, Spain.Retrospective case series.Uncorrected (UDVA) and corrected (CDVA) distance visual acuities, refraction, and intraocular pressure were evaluated during a medium-term follow-up. Postoperative complications were also studied.The study enrolled 35 eyes (mean preoperative spherical equivalent [SE] -10.25 diopters [D] ± 3.19 [SD]) of 20 patients with a mean age of 31.83 ± 8.87 years and a mean follow-up of 57.34 ± 9.24 months. The mean UDVA improved…

AdultMaleIntraocular pressuremedicine.medical_specialtyPhakic Intraocular LensesVisual acuitygenetic structuresVisual AcuityPhakic intraocular lensRefraction OcularMedium termYoung AdultPostoperative ComplicationsLens Implantation IntraocularOphthalmologyMedicineHumansDioptreIntraocular PressureRetrospective Studiesbusiness.industryHigh myopiaPosterior Eye SegmentMiddle AgedRefractioneye diseasesSensory SystemsPosterior chamber phakic intraocular lensOphthalmologyTreatment OutcomeMyopia DegenerativeSurgeryFemalemedicine.symptombusinessFollow-Up StudiesJournal of cataract and refractive surgery
researchProduct

Assessment of corneal morphological changes induced by the use of daily disposable contact lenses.

2015

To assess the effect of different disposable soft contact lenses upon corneal thickness, and upon anterior and posterior corneal curvatures using a dual-Scheimpflug imaging based device.Twenty-eight young, healthy subjects wore four different types of daily disposable soft contact lenses on four different days: Dailies Total1, Proclear 1 Day, Clariti 1-Day and 1-Day Acuvue Moist. The lenses had different material and water content. Pachymetry maps and keratometry values were obtained using the Galilei G4 twice a day: one before putting the lens on and one after an eight-hour period of contact-lens wear. Measurements were also recorded without any contact lenses being worn during a day.Clari…

AdultMaleVisual Acuitylaw.inventionCorneaYoung AdultlawMyopiaMedicineHumansDisposable EquipmentKeratometerCorneal curvaturebusiness.industryHealthy subjectsCorneal TopographyGeneral MedicineEquipment DesignContact Lenses Hydrophiliceye diseasesContact lensLens (optics)OphthalmologyOptometryDaily disposableFemalesense organsThickeningbusinessOptometryFollow-Up StudiesContact lensanterior eye : the journal of the British Contact Lens Association
researchProduct

Comparison of Immersion Ultrasound, Partial Coherence Interferometry, and Low Coherence Reflectometry for Ocular Biometry in Cataract Patients

2011

PURPOSE: To compare ocular biometry parameters measured with immersion ultrasound, partial coherence interferometry, and low coherence reflectometry in cataract patients. METHODS: Measurements of axial length and anterior chamber depth were analyzed and compared using immersion ultrasound, partial coherence interferometry, and low coherence reflectometry. Keratometry (K), flattest axis, and white-to-white measurements were compared between partial coherence interferometry and low coherence reflectometry. Seventy-eight cataract (LOCS II range: 1 to 3) eyes of 45 patients aged between 42 and 90 years were evaluated. A subanalysis as a function of cataract degree was done for axial length and…

AdultMalemedicine.medical_specialtyBiometryMaterials scienceAnterior ChamberDiagnostic Techniques OphthalmologicalCataractlaw.inventionOpticslawOphthalmologymedicineHumansBody Weights and MeasuresReflectometryAgedUltrasonographyAged 80 and overKeratometerbusiness.industryUltrasoundAnova testAxial lengthMiddle AgedAxial Length EyeOphthalmologyInterferometryInterferometryPartial coherence interferometryFemaleSurgeryUltrasonographybusinessJournal of Refractive Surgery
researchProduct

VisuMax®femtosecond laser for corneal refractive surgery

2008

Femtosecond lasers are increasingly present in ophthalmologic surgical theaters for a variety of reasons. These include faster and better visual outcomes, increased accuracy and predictability for corneal flap thickness in laser in situ keratomileusis procedures. Recent applications of modern femtosecond lasers have broadened the range of uses: keratoplasty, intrastromal segment insertion and even glaucoma and presbyopia surgery. This device profile provides an overview of the advantages of femtosecond lasers in ophthalmic surgery, paying special attention to the new VisuMax® femtosecond laser from Zeiss/Meditec.

genetic structuresbusiness.industrymedicine.medical_treatmentBiomedical EngineeringGlaucomaKeratomileusisPresbyopiaequipment and suppliesmedicine.diseaseLasereye diseaseslaw.inventionOphthalmologyOpticsCorneal surgerylawRefractive surgeryFemtosecondmedicinesense organsbusinessOptometryOphthalmic surgeryExpert Review of Ophthalmology
researchProduct

Refractive Lens Exchange with Foldable Toric Intraocular Lens

2009

To assess visual and refractive outcomes, and rotational stability after refractive lens exchange (RLE) with toric intraocular lens (IOL) implantation to correct ametropia and preexisting astigmatism.Prospective, nonrandomized, observational case series (self-controlled).This prospective, nonrandomized, and self-controlled study included 32 eyes of 19 consecutive patients with more than 1.00 diopter (D) of preexisting corneal astigmatism having RLE with AcrySof Toric IOL implantation (Alcon Laboratories Inc, Fort Worth, Texas, USA). Uncorrected visual acuity (UCVA), best-corrected visual acuity (BCVA), refractive sphere, and keratometric and refractive cylinder were recorded preoperatively …

Malemedicine.medical_specialtyVisual acuitygenetic structuresmedicine.medical_treatmentAcrylic ResinsVisual AcuityIntraocular lensVisual phenomenaAstigmatismRefractive lens exchangeRefraction OcularLens Implantation IntraocularSurveys and QuestionnairesOphthalmologyMyopiamedicineHumansProspective StudiesDioptreAgedLenses IntraocularPhacoemulsificationbusiness.industryAstigmatismMiddle Agedmedicine.diseaseeye diseasesOphthalmologyAlcon LaboratoriesEyeglassesPatient SatisfactionOptometryFemalesense organsmedicine.symptombusinessCorneal astigmatismAmerican Journal of Ophthalmology
researchProduct

Visual performance comparison between contact lens-based pinhole and simultaneous vision contact lenses.

2011

Background The aim was to evaluate the visual performance provided with a contact lens-based pinhole design against a simultaneous vision multifocal contact lens. Methods In a cross-over study at the University of Valencia, 22 presbyopic patients were evaluated using an artificial pupil fitted on the non-dominant eye and the simultaneous vision PureVision Multifocal contact lenses. After one month of contact lens wear, binocular distance visual acuity (BDVA), binocular near visual acuity (BNVA), defocus curve, binocular distance contrast sensitivity, binocular near contrast sensitivity, and stereoacuity were measured, under photopic conditions (85 cd/m2). In addition, binocular distance vis…

MaleVisual acuitygenetic structuresMesopic visionContact Lensesmedia_common.quotation_subjectVisual AcuityContrast SensitivitymedicineContrast (vision)HumansMathematicsmedia_commonAgedVision BinocularCross-Over StudiesColor VisionEquipment DesignPresbyopiaMiddle Agedeye diseasesStereoscopic acuityContact lensOphthalmologyStereopsisTreatment OutcomeOptometryFemalemedicine.symptomBinocular visionOptometryPhotopic visionFollow-Up StudiesClinicalexperimental optometry
researchProduct

Influence of contrast polarity on the accommodative response☆

2018

espanolObjetivo Evaluar los cambios de la respuesta acomodativa del ojo al leer un texto en diferentes condiciones de polaridad de contraste: letras negras sobre fondo blanco (condicion BoW) y letras blancas sobre fondo negro (condicion WoB). Metodos En este estudio experimental participaron dieciocho sujetos de edades comprendidas entre 21 y 41 anos. Se obtuvo objetivamente la respuesta acomodativa (AR) del ojo al leer un texto con polaridad de contraste BoW o WoB con un sistema de optica adaptativa que corregia todas las aberraciones salvo las propias del sujeto. Se estudiaron dos tamanos de letra diferentes (condiciones de agudeza visual), mostrados en una micropantalla. Se midio la AR d…

AdultMaleAccommodative responseOriginal articleBlack-on-white textgenetic structuresmedia_common.quotation_subjectPupil diameterVisual AcuityAgudeza visualContrast Sensitivity03 medical and health sciencesYoung Adult0302 clinical medicineAccommodative responseAyudas ópticas para baja visiónContrast polarityPolaridad de contrasteContrast (vision)Humansmedia_commonPhysicsAnalysis of VariancePupil sizeAccommodation OcularLow vision aidseye diseasesTexto blanco sobre negroWhite-on-black textReading030221 ophthalmology & optometryRespuesta acomodativaFemalesense organsHumanities030217 neurology & neurosurgeryTexto negro sobre blancoPhotic StimulationOptometryJournal of Optometry
researchProduct

Sensibilidad al contraste tras cirugía de cristalino transparente con lente intraocular multifocal asférica difractiva

2013

PURPOSE: To evaluate distance and near contrast sensitivity (CS) under photopic and mesopic conditions before and after refractive lens exchange (RLE) and implantation of the aspheric AcrySof®ReSTOR® (SN6AD3 model) intraocular lens (IOL). METHODS:Seventy-four eyes of 37 patients after RLE underwent bilateral implantation with the aspheric AcrySof ReSTOR IOL. The patient sample was divided into myopic and hyperopic groups. Monocular uncorrected visual acuity at distance and near (UCVA and UCNVA, respectively) and monocular best corrected visual acuity at distance and near (BCVA and BCNVA, respectively) were measured before and 6 months postoperatively. Monocular CS function was measured at t…

HiperopiaHyperopiaPhacoemulsificationVisual acuityMiopíaLens implantation intraocularImplantación de lentes intraocularesMyopiaAgudeza visualLens cristallineCristalinoFacoemulsificación
researchProduct

Visual Acuity and Contrast Sensitivity in Eyes Implanted with Aspheric and Spherical Intraocular Lenses

2009

Purpose To compare visual acuity and contrast sensitivity (CS) in eyes implanted with aspheric and spherical intraocular lenses (IOLs) after cataract surgery. Design Randomized, prospective study. Participants Five hundred twenty-four eyes from 262 cataract surgery patients implanted with 2 IOL models: the AcrySof IQ (262 eyes) and AcrySof SN60AT (262 eyes; Alcon Laboratories, Fort Worth, TX). Methods High-contrast photopic best-corrected distance visual acuity (BCVA) and CS under photopic (85 cd/m 2 ) and mesopic (6 cd/m 2 ) conditions were measured. Pupil diameter was analyzed for distance vision under both lighting conditions. Follow-up was carried out for 6 months in all patients. Main …

Malemedicine.medical_specialtyVisual acuityLightPseudophakiagenetic structuresMesopic visionmedia_common.quotation_subjectmedicine.medical_treatmentAcrylic ResinsVisual AcuityDark AdaptationIntraocular lensCataract ExtractionProsthesis DesignContrast SensitivityLens Implantation IntraocularVision MonocularOphthalmologymedicineHumansContrast (vision)Prospective StudiesAgedmedia_commonLenses Intraocularbusiness.industryPupilCataract surgeryeye diseasesOphthalmologyAlcon LaboratoriesIntraocular lensesOptometryFemalesense organsmedicine.symptombusinessPhotopic visionOphthalmology
researchProduct

Differences in visual performance of AcrySof ReSTOR IOL in high and low myopic eyes.

2009

PURPOSE To determine the differences in refractive and visual results obtained in eyes with high and low myopia after multifocal intraocular lens (IOL) implantation. METHODS Monocular visual acuity for distance and near, with and without distance correction, and photopic and mesopic contrast sensitivity were measured at 6 months after surgery in 152 myopic eyes implanted with the AcrySof ReSTOR Natural (SN60D3) IOL. Two groups were created: high and low myopia (76 eyes in each). RESULTS Monocular best distance-corrected visual acuity was 0.02+/-0.06 logMAR for low myopes and 0.05+/-0.09 logMAR for high myopes. Monocular best distance-corrected near visual acuity was 0.04+/-0.05 and 0.07+/-0…

AdultMalemedicine.medical_specialtyVisual acuitygenetic structuresPseudophakiaMesopic visionmedia_common.quotation_subjectProsthesis DesignRefraction OcularSeverity of Illness IndexContrast Sensitivity03 medical and health sciences0302 clinical medicineLens Implantation IntraocularOphthalmologymedicineMyopiaContrast (vision)HumansProspective Studiesmedia_commonAgedLenses IntraocularMonocularbusiness.industryGeneral MedicineMultifocal intraocular lensMiddle AgedDistance correctioneye diseasesOphthalmologyTreatment Outcome030221 ophthalmology & optometryFemalesense organsSpatial frequencymedicine.symptombusiness030217 neurology & neurosurgeryPhotopic visionEuropean journal of ophthalmology
researchProduct

Assessment of modifications in thickness, curvatures, and volume upon the cornea caused by disposable soft contact lens wear.

2015

Purpose To assess the effect of different disposable soft contact lenses on several corneal parameters–-thickness, anterior and posterior curvature, and volume–-by means of a Scheimpflug imaging-based device (Pentacam HR). Diurnal variations of these parameters were taken into account. Methods Twenty-one young, healthy subjects wore 4 different types of daily disposable soft contact lenses on 4 different days: Dailies AquaComfort Plus, SofLens, Dailies Total1, and Acuvue TruEye. The lenses had different material and water content. Pachymetry and curvature maps and corneal volume values were obtained using the Pentacam HR twice a day: one before putting the lens on and one after an 8-hour pe…

AdultMaleEffects of long-term contact lens wear on the corneaMaterials sciencegenetic structuresCorneal PachymetryScheimpflug principleVisual AcuityCurvatureCorneaYoung AdultOpticsCorneamedicineMyopiaHumansCorneal pachymetryDisposable Equipmentmedicine.diagnostic_testbusiness.industryCorneal TopographyGeneral MedicineOrgan SizeCorneal topographyContact Lenses Hydrophiliceye diseasesCircadian RhythmContact lensOphthalmologymedicine.anatomical_structureFemalesense organsDisposable EquipmentbusinessBiomedical engineeringEuropean journal of ophthalmology
researchProduct

Visual simulation through different intraocular lenses using adaptive optics: Effect of tilt and decentration

2011

Purpose To analyze visual quality differences between intraocular lenses (IOLs) and assess the impact of IOL decentration and tilt on visual quality. Setting University of Valencia, Valencia, Spain. Design Cohort study. Methods The crx1 adaptive optics visual simulator was used to simulate the wavefront aberration pattern of 2 commercially available aspheric aberration-correcting IOLs (Acrysof IQ SN60WF and Tecnis ZA9003) and 2 spherical IOLs (Akreos Adapt and Triplato) in 5 situations: centered, decentered 0.2 mm and 0.4 mm, and tilted 2 degrees and 4 degrees. Monocular distance visual acuity at 100%, 50%, and 10% contrast and the depth of focus were measured. Results Ten eyes of 10 patien…

AdultDepth of focusCorneal Wavefront AberrationVisual acuityPseudophakiagenetic structuresmedia_common.quotation_subjectVisual AcuityArtificial Lens Implant MigrationCohort StudiesYoung AdultAberrometryPsychophysicsmedicineHumansContrast (vision)Adaptive opticsmedia_commonMathematicsLenses IntraocularDepth PerceptionMonocularAberrometryModels Theoreticalequipment and supplieseye diseasesSensory SystemsOphthalmologySpherical aberrationTilt (optics)OptometrySurgerysense organsmedicine.symptomJournal of Cataract and Refractive Surgery
researchProduct

Prevention of hyperopic surprise after LASIK in patients with refractive multifocal intraocular lenses.

2011

Purpose. Three cases of patients who developed a similar hyperopic defect in refraction following laser in situ keratomileusis (LASIK) after multifocal intraocular lens (IOL) implantation are described. Methods. Ophthalmologic evaluation including refractive status, corrected and uncorrected visual acuity (both at far and near), and corneal topography in patients presenting similar hyperopic refractive surprise in one eye as a result of LASIK refinement of residual ametropia after refractive multifocal IOL implantation. Results. Laser in situ keratomileusis enhancement for residual ametropia of −1.00 to −1.50 D in patients with a prior implantation of refractive multifocal IOL resulted in a…

Malemedicine.medical_specialtygenetic structuresmedicine.medical_treatmentKeratomileusis Laser In SituVisual AcuityKeratomileusisCataract ExtractionRefraction OcularBioptics (surgery)Lens Implantation IntraocularOphthalmologymedicineMyopiaHumansIn patientLenses Intraocularmedicine.diagnostic_testbusiness.industryLASIKCorneal TopographyGeneral MedicineMultifocal intraocular lensMiddle AgedCorneal topographySubjective refractionRefractioneye diseasesOphthalmologyHyperopiaFemalesense organsbusinessEuropean journal of ophthalmology
researchProduct

Artificial pupil versus contralateral balanced contact lens fit for presbyopia correction.

2014

Purpose: To assess and compare the effects of contact lens-based artificial pupil design and contralateral balanced multifocal contact lens combination (CBMCLC) on visual performance. Methods: This randomized crossover study conducted at the University of Valencia, Spain included 38 presbyopic patients using an artificial pupil contact lens in the nondominant eye and a CBMCLC. After a month of lens wear, the binocular distance visual acuity (BDVA), binocular near visual acuity (BNVA), defocus curve, binocular distance, and near contrast sensitivity and near stereoacuity (NSA) were measured under photopic conditions (85 cd/m2). Moreover, BDVA and binocular distance contrast sensitivity were …

MaleVisual acuitygenetic structuresMesopic visionmedia_common.quotation_subjectLentes de contatoVisual AcuityPupilContrast Sensitivitylcsh:OphthalmologymedicineContrast (vision)HumansContact lensesPresbyopia/rehabilitationPupilaPresbiopia/reabilitaçãomedia_commonMathematicsCross-Over StudiesColor VisionPupilGeneral MedicinePresbyopiaEquipment DesignPresbyopiaMiddle Agedmedicine.diseaseContact Lenses HydrophilicAjuste de próteseeye diseasesContact lensStereoscopic acuityOphthalmologyTreatment Outcomelcsh:RE1-994Dominância ocularOptometryFemalemedicine.symptomProsthesis fitting dominance ocularPhotopic visionArquivos brasileiros de oftalmologia
researchProduct

Myopic astigmatism correction: comparison of a Toric Implantable Collamer Lens and a bioptics technique by an adaptive optics visual simulator.

2013

Purpose To compare the optical and visual quality of a simulated Toric Implantable Collamer Lens (TICL) and a bioptics technique to treat high myopic astigmatism. Methods An adaptive optics visual simulator was used to simulate the vision after TICL implantation and a bioptics procedure from the wavefront aberration pattern for moderate and high-myopic astigmatism. Visual acuity (VA) at different contrasts and contrast sensitivity (CS) at 10, 20 and 25 cycles degree−1 were measured for 3 and 5-mm pupils. Modulation Transfer Function (MTF) and Point Spread Function (PSF) were calculated for a 5-mm pupil. Results At a 3-mm pupil we only found statistically significant differences in VA betwee…

Point spread functionAdultMalePhakic Intraocular LensesVisual acuityCorneal Wavefront AberrationAdolescentVisual AcuityAstigmatismPupilContrast SensitivityYoung AdultBioptics (surgery)Lens Implantation IntraocularOptical transfer functionmedicineMyopiaHumansAdaptive opticsSimulationMathematicsAberrometryAstigmatismmedicine.diseaseSensory SystemsOphthalmologyFemaleSpatial frequencymedicine.symptomOptometryOphthalmicphysiological optics : the journal of the British College of Ophthalmic Opticians (Optometrists)
researchProduct

Age-related changes in the human visual system and prevalence of refractive conditions in patients attending an eye clinic.

2008

PURPOSE: To retrospectively report the trends of change in several parameters of the human visualsystem over a wide age range in patients attending an eye clinic. SETTING: University of Valencia, Valencia, Spain. METHODS: The clinical records of 2654 patients were retrospectively reviewed, and the age, sex, spherocylindrical refraction, visual acuity, keratometry, and intraocular pressure were obtained. Descriptive values for each parameter and the correlations with age and between different parameters were calculated. Vectorial components of refraction, including blur, were also derived from clinical refractive data and then analyzed. RESULTS: Several parameters changed significantly with …

MaleRefractive errorAgingVisual acuitygenetic structuresVisual Acuity0302 clinical medicineMyopiaPrevalence10. No inequalityChildAged 80 and overMiddle AgedRefractive ErrorsSensory SystemsOptical qualitymedicine.anatomical_structureChild PreschoolHuman visual system modelFemalemedicine.symptomAdultmedicine.medical_specialtyAdolescentVision DisordersAstigmatismRefraction Ocular03 medical and health sciencesAgeAge DistributionAge relatedOphthalmologymedicineHumansIn patientIntraocular PressureVision OcularAgedRetrospective StudiesScience & Technologybusiness.industryRefractive errorInfantmedicine.diseaseeye diseasesOphthalmologyCross-Sectional Studies030221 ophthalmology & optometryOptometrySurgeryHuman eyesense organsbusiness030217 neurology & neurosurgeryJournal of cataract and refractive surgery
researchProduct

Ocular autofluorescence in diabetes mellitus. A review

2016

Diabetes mellitus is a metabolic disease with a considerable impact on healthcare owing to its increased prevalence and high mortality rate. Structural, morphological, and physiological changes in each of the ocular components have been described in detail. Autofluorescence has been described as a good indicator of metabolic activity. The aim of the present review is to provide an overview of ocular endogenous fluorophores in the cornea, the crystalline lens, and the retinal pigment epithelium, the effects of diabetes mellitus and therefore the potential of autofluorescence assessment for screening and monitoring changes in diabetic patients.

0301 basic medicinemedicine.medical_specialtyRetinal pigment epitheliumbusiness.industryEndocrinology Diabetes and Metabolismmedicine.diseaseeye diseases03 medical and health sciencesAutofluorescence030104 developmental biology0302 clinical medicinemedicine.anatomical_structureOphthalmologyDiabetes mellitusCornea030221 ophthalmology & optometryMedicinesense organsMetabolic diseasebusinessMetabolic activityJournal of Diabetes
researchProduct

Intrasubject repeatability of corneal power, thickness, and wavefront aberrations with a new version of a dual rotating Scheimpflug–Placido system

2014

Purpose To determine the intrasubject repeatability of a recently introduced dual-camera rotating Scheimpflug–Placido imaging system (Galilei G4) in determining corneal thickness, power, and wavefront aberrations in young healthy subjects. Setting University of Valencia, Valencia, Spain. Design Prospective evaluation of diagnostic technology. Methods The study comprised right eyes of 25 subjects aged 20 to 40 years with a spherical equivalent ranging from −4.25 to +1.00 diopters. The central corneal thickness, thinnest point value and location, anterior and posterior surface curvatures, total corneal power, and corneal wavefront aberrations were measured for distance vision using the dual S…

AdultMaleChord (geometry)medicine.medical_specialtyCorneal Wavefront AberrationCorneal Pachymetrygenetic structuresIntraclass correlationScheimpflug principleDiagnostic Techniques OphthalmologicalAstigmatismRefraction OcularCorneaYoung AdultOpticsOphthalmologyPhotographymedicineHumansProspective StudiesCorneal pachymetryDioptreMathematicsObserver VariationWavefrontmedicine.diagnostic_testbusiness.industryReproducibility of ResultsRepeatabilitymedicine.diseaseHealthy Volunteerseye diseasesSensory SystemsOphthalmologyFemaleSurgerysense organsbusinessJournal of Cataract and Refractive Surgery
researchProduct

Optical quality after instillation of eyedrops in dry-eye syndrome

2010

Purpose To study the effect of eyedrop instillation on the optical quality of the air–tear film interface at the anterior cornea in cases of dry eye. Setting University of Valencia, Valencia, Spain. Methods Corneal aberrations (total, spherical-like, and coma-like) were determined from corneal elevation maps and purpose-designed software in cases of dry eye before, immediately after, and 10 minutes after lubricating eyedrop instillation (Blink Intensive Tears). All data were decomposed using Zernike polynomials to yield the root-mean-square wavefront deviations for pupil diameters of 3.0 mm and 5.5 mm. Outcome measures included comparison with clinical tear breakup time (TBUT). Results Wave…

Malemedicine.medical_specialtyCorneal Wavefront Aberrationgenetic structuresmedicine.medical_treatmentEye diseaseVision DisordersDry Eye SyndromesPupilCorneaCorneaOphthalmologymedicineHumansmedicine.diagnostic_testbusiness.industryAirCorneal TopographyMiddle Agedmedicine.diseaseCorneal topographyeye diseasesSensory SystemsOptical qualityOphthalmologyArtificial tearsmedicine.anatomical_structureTearsTearsDry Eye SyndromesFemaleSurgerysense organsOphthalmic SolutionsbusinessJournal of Cataract and Refractive Surgery
researchProduct

Determination of corneal volume from anterior topography and topographic pachymetry: application to healthy and keratoconic eyes

2009

Purpose: To describe a method to measure corneal volume from topography and pachymetry, and test its clinical use on a sample of healthy human subjects and a case of circumscribed posterior keratoconus. Methods: Corneal curvature (PCT 200® corneal topography system; Optopol Technology SA, Zawiercie, Poland) and ultrasonic topographic pachometry on 25 points (Ophthasonic ® A-Scan/Pachometer III; Teknar Inc., St Louis, MO, USA) were measured on each of 12 young healthy corneas and one cornea suffering from circumscribed posterior keratoconus. Topography and pachymetry data were used to calculate the coordinates for the corresponding points on the posterior surface of the cornea. TableCurve 3D…

MaleKeratoconusmedicine.medical_specialtygenetic structuresEye diseaseKeratoconusSensitivity and SpecificityCorneaYoung Adult03 medical and health sciences0302 clinical medicineCorneaOphthalmologymedicineHumansPosterior keratoconusCorneal pachymetry030304 developmental biology0303 health sciencesmedicine.diagnostic_testbusiness.industryCorneal TopographyCorneal topographymedicine.diseaseeye diseasesSensory SystemsOphthalmologymedicine.anatomical_structure030221 ophthalmology & optometryFemalesense organsTomographybusinessTomography Optical CoherenceOptometryVolume (compression)Ophthalmic and Physiological Optics
researchProduct

Contrast sensitivity and color perception with orange and yellow intraocular lenses

2012

To evaluate contrast sensitivity function (CSF) and color vision after implantation of either orange or yellow-tinted intraocular lenses (IOLs).Fifty-six eyes of 28 cataract patients who had bilateral implantation of orange-tinted (PC440Y Orange, Ophtec), yellow-tinted (AcrySof Natural SN60AT, Alcon), or clear (AcrySof SA60AT, Alcon) IOLs were examined. Six months postoperatively, monocular CSF under photopic and mesopic (with and without glare) conditions were measured using the Functional Visual Analyzer. Color discrimination was determined with the Farnsworth-Munsell 100-Hue test.Patients implanted with orange-tinted, yellow-tinted, or clear IOLs displayed similar CSF values, with no sta…

Male0301 basic medicinemedicine.medical_specialtygenetic structuresColor visionmedicine.medical_treatmentMesopic VisionVisual AcuityOrange (colour)Prosthesis DesignColor discriminationContrast Sensitivity03 medical and health sciences0302 clinical medicineOpticsLens Implantation IntraocularOphthalmologyHumansMedicineProsthesis designProspective StudiesAgedLenses IntraocularPhacoemulsificationColor Visionbusiness.industryGeneral MedicinePhacoemulsificationeye diseasesOphthalmology030104 developmental biologyIntraocular lenses030221 ophthalmology & optometryFemalesense organsbusinessColor PerceptionEuropean Journal of Ophthalmology
researchProduct

Toric intraocular lens versus opposite clear corneal incisions to correct astigmatism in eyes having cataract surgery.

2009

To compare toric intraocular lens (IOL) implantation with paired opposite clear corneal incisions (OCCIs) for astigmatism correction in patients having cataract surgery.Ophthalmology Service, Donostia Hospital, San Sebastián, Spain.This randomized prospective clinical study comprised eyes with more than 1.00 diopter (D) of preexisting corneal astigmatism. One group had AcrySof toric IOL implantation and the other, paired 2.75 mm/3.20 mm OCCIs in the steep axis with spherical IOL implantation. Uncorrected (UCVA) and best corrected (BCVA) visual acuity, refraction, corneal and total higher-order aberrations (HOAs), photopic and mesopic contrast sensitivity, and toric IOL axis were measured 3 …

Malemedicine.medical_specialtyRefractive errorgenetic structuresmedicine.medical_treatmentVisual AcuityIntraocular lensAstigmatismContrast SensitivityCorneaPostoperative ComplicationsLens Implantation IntraocularOphthalmologymedicineHumansProspective StudiesIntraoperative ComplicationsDioptreAgedLenses IntraocularPhacoemulsificationmedicine.diagnostic_testbusiness.industryAstigmatismCorneal TopographyPhacoemulsificationCataract surgeryCorneal topographymedicine.diseaseeye diseasesSensory SystemsToric lensOphthalmologySurgeryFemalesense organsbusinessJournal of cataract and refractive surgery
researchProduct

Analysis of the possible benefits of aspheric intraocular lenses: review of the literature.

2008

We reviewed recently published studies that analyzed the visual and optical quality in eyes with different spherical and aspheric intraocular lenses (IOLs). Recent studies focused on visual quality metrics, such as visual acuity and contrast sensitivity, under photopic and mesopic lighting conditions and optical metrics, such as wavefront aberrations, especially spherical aberration. The results in this review were used in an attempt to understand whether there is a visual and/or optical benefit of implanting aspheric IOLs over implanting spherical IOLs.

Visual acuitygenetic structuresMesopic visionmedia_common.quotation_subjectmedicine.medical_treatmentVisual AcuityIntraocular lensProsthesis DesignContrast SensitivityOpticsLens Implantation IntraocularMedicineContrast (vision)Humansmedia_commonWavefrontLenses Intraocularbusiness.industryeye diseasesSensory SystemsOphthalmologySpherical aberrationIntraocular lensesOptometrySurgerysense organsmedicine.symptombusinessPhotopic visionJournal of cataract and refractive surgery
researchProduct

Prevalence of corneal astigmatism before cataract surgery.

2008

To analyze the prevalence and presentation patterns of corneal astigmatism in cataract surgery candidates.University of Valencia, Valencia, Spain.Refractive and keratometric values were measured before surgery in patients having cataract extraction. Descriptive statistics of refractive and keratometric cylinder data were analyzed and correlated by age ranges.Refractive and keratometric data from 4,540 eyes of 2,415 patients (mean age 60.59 years +/- 9.87 [SD]; range 32 to 87 years) differed significantly when the patients were divided into 10-year subsets. There was a trend toward less negative corneal astigmatism values, except the steepest corneal radius and the J(45) vector component, in…

AdultMaleRefractive errormedicine.medical_specialtygenetic structuresmedicine.medical_treatmentEye diseaseIntraocular lensCataract ExtractionAstigmatismCorneal DiseasesVision disorderAge DistributionCorneaOphthalmologymedicinePrevalenceHumansProspective StudiesAgedAged 80 and overbusiness.industryAstigmatismCataract surgeryMiddle Agedmedicine.diseaseeye diseasesSensory SystemsOphthalmologymedicine.anatomical_structureSpainOptometrySurgeryFemalesense organsmedicine.symptombusinessCorneal astigmatismJournal of cataract and refractive surgery
researchProduct

Diurnal variations in visual performance for disposable contact lenses.

2013

The purpose of this study is to compare the visual performance provided by different daily disposable contact lenses and to analyze its variation over time.Visual performance was evaluated in terms of visual acuity (VA) and contrast sensitivity (CS) in 15 myopic subjects (-0.50 to -4.00 diopters) who had been previously fitted with each one of the following seven types of soft contact lenses: DAILIES TOTAL1 (Alcon, Forth Worth, TX), DAILIES AquaComfort Plus (Alcon), 1-DAY ACUVUE TruEye (JohnsonJohnson Vision Care, Jacksonville, FL), 1-DAY ACUVUE MOIST (JohnsonJohnson Vision Care), SofLens daily disposable (BauschLomb, Rochester, NY), Proclear 1 Day (CooperVision, Fairport, NY), and Clariti …

AdultMaleVisual acuitygenetic structuresmedia_common.quotation_subjectVisual AcuityContrast SensitivityYoung AdultmedicineMyopiaContrast (vision)HumansDisposable EquipmentVision Ocularmedia_commonMathematicsContact Lenses Hydrophiliceye diseasesCircadian RhythmOphthalmologyOptometryDaily disposableFemalesense organsDisposable Equipmentmedicine.symptomOptometryOptometry and vision science : official publication of the American Academy of Optometry
researchProduct

Visual Performance of a Multifocal Toric Soft Contact Lens

2012

PURPOSE To evaluate the visual performance of the Proclear multifocal toric contact lens (CL; CooperVision, US) for both presbyopia and astigmatism correction. METHODS In this crossover study design, 20 presbyopic subjects with astigmatism were fitted in a random order with either Proclear multifocal toric CL or Proclear toric single vision distance CL (DCL) combined with reading spectacles. After 1 month, high-contrast distance visual acuity, near high-contrast visual acuity, distance contrast sensitivity (CS) under photopic and mesopic conditions without and with glare, near CS, defocus curve, and stereopsis were measured. Subjects were then refitted with the alternative correction, and t…

Malemedicine.medical_specialtyVisual acuitygenetic structuresMesopic visionmedia_common.quotation_subjectVisual AcuityAstigmatismRefraction OcularOphthalmologymedicineHumansContrast (vision)AgedMathematicsmedia_commonCross-Over StudiesGlare (vision)Equipment DesignPresbyopiaMiddle AgedContact Lenses HydrophilicRefractive Errorsmedicine.diseaseeye diseasesContact lensOphthalmologyFemalemedicine.symptomOptometryPhotopic visionOptometry and Vision Science
researchProduct

Contrast sensitivity after refractive lens exchange with a multifocal diffractive aspheric intraocular lens

2013

Purpose: To evaluate distance and near contrast sensitivity (CS) under photopic and mesopic conditions before and after refractive lens exchange (RLE) and implantation of the aspheric AcrySof ReSTOR (SN6AD3 model) intraocular lens (IOL) Methods: Sixty eyes of 30 consecutive patients after RLE underwent bilateral implantation with the aspheric AcrySof ReSTOR IOL. The patients sample was divided into myopic [n=15, mean spherical equivalent (SE) -6.87± 2.03 diopters (D)] and hyperopic (n=15, mean SE +4.52±1.14 D) groups. Monocular uncorrected visual acuity at distance and near (UCVA and UCNVA, respectively) and monocular best corrected visual acuity at distance and near (BCVA and BCNVA, respec…

Malegenetic structuresMesopic visionmedicine.medical_treatmentVisual AcuityIntraocular lensMyopia/surgerylaw.inventionLens Implantation Intraocularlcsh:OphthalmologylawMyopiaContrast (vision)Prospective StudiesDioptreMathematicsmedia_commonLenses Intraoculareducation.field_of_studyGeneral MedicineMiddle AgedFacoemulsificaciónLens (optics)HiperopiaHyperopiaFemalePhotopic visionmedicine.medical_specialtyMiopíaVisual acuitymedia_common.quotation_subjectPopulationCataract ExtractionContrast SensitivityVision MonocularOphthalmologyImplantación de lentes intraocularesmedicineHumansHyperopia/physiopathologyAgudeza visualeducationCristalinoAgedMonocularPhacoemulsificationDistance PerceptionLens cristalline/surgeryeye diseasesOphthalmologyLens implantation intraocularlcsh:RE1-994Optometrysense organs
researchProduct

A pilot study on the differences in wavefront aberrations between two ethnic groups of young generally myopic subjects

2008

A comparative population-based cross-sectional study design was used to examine the prevalence of wavefront patterns in two different ethnic groups, and the relationship of these patterns with ocular biometrics and gender. The Shin–Nippon SRW5000 open field autorefractor, the Wavefront Analysis Supported Customized Ablation (WASCA) wavefront analyser and the IOLMaster were used to determine wavefront aberrations, mean spherical equivalent (SE) refractive error and axial length (AL). Seventy-four eyes from 74 young healthy subjects (44 British Asians, 30 Caucasians; 36 men, 38 women; mean age 22.51 ± 3.89 years) with mean SE averaging )1.90 ± 2.76 D (range )10.88 to +2.19 D) were examined. R…

WavefrontRefractive erroreducation.field_of_studyPopulationComa (optics)medicine.diseaseSensory SystemsPearson product-moment correlation coefficient03 medical and health sciencesOphthalmologysymbols.namesakeAberrations of the eye0302 clinical medicineAutorefractorStatisticsLinear regression030221 ophthalmology & optometrymedicinesymbolsOptometryeducation030217 neurology & neurosurgeryOptometryMathematicsOphthalmic and Physiological Optics
researchProduct

Multisectorial changes in the ciliary muscle during accommodation measured with high-resolution optical coherence tomography

2019

ABSTRACT Purpose: To measure changes in the anterior ciliary muscle during accommodation at the nasal, superior, temporal, and inferior sectors by means of an anterior chamber optical coherence tomographer, and correlate them with vergence changes. Methods: Twenty-four subjects with healthy, phakic eyes, whose mean age was 27.1 ± 8.9 years, underwent measurement with an anterior chamber optical coherence tomographer. The anterior ciliary muscle was measured at the nasal, temporal, superior, and inferior sectors for 0, -1, -2, and -3 D of vergence. A linear model was used to assess the correlation of each eye parameter with the accommodative demand. Results: The anterior ciliary muscle area …

AdultMalemedicine.medical_specialtyBiometryHigh resolutionVergenceStatistics NonparametricYoung Adult03 medical and health sciences0302 clinical medicinelcsh:OphthalmologyOptical coherence tomographyReference ValuesOphthalmologyHumansMedicineTomographyMúsculo ciliarBiometriaAnalysis of Variancemedicine.diagnostic_testbusiness.industryCiliary BodyOptical coherenceBiomechanicsAccommodation OcularPresbyopiaGeneral MedicinePresbyopiamedicine.diseaseBiomechanical PhenomenaCiliary muscleOphthalmologyCiliary musclelcsh:RE1-994Acomodação ocularTomografia de coerência ópticaAccommodation ocularLinear Models030221 ophthalmology & optometryPositive relationshipFemalesense organsPresbiopiabusinessAccommodationTomography Optical CoherenceArquivos Brasileiros de Oftalmologia
researchProduct

Preliminary in vivo positional analysis of a posterior chamber phakic intraocular lens by optical coherence tomography and its correlation with clini…

2012

Purpose: To analyze by spectral-domain optical coherence tomography the anatomical relationship of a specific type of posterior chamber phakic intraocular lens (pIOL) implanted in cases of high to moderate myopia with the adjacent intraocular structures and to correlate it with clinical outcomes. Methods: Prospective observational case series including 18 eyes with high to moderate myopia (spherical equivalent between −5.88 and −15.75 D) of 9 patients (age range, 29–49 years) undergoing bilateral Phakic Refractive Lens (PRL, Zeiss) implantation. Postoperative visual acuity, refraction, contrast sensitivity (CS), and ocular higher order aberrations (HOA) were evaluated. Furthermore, the in v…

medicine.medical_specialtygenetic structuresSpectral domainPositional analysislcsh:OphthalmologyOptical coherence tomographyIn vivoOphthalmologymedicinelcsh:QC350-467Optical coherence tomographymedicine.diagnostic_testbusiness.industrySpectral-domaineye diseasesPosterior chamber phakic intraocular lensTomografía de coherencia ópticaLentes refractivas fáquicaslcsh:RE1-994Anatomical relationshipOriginal Articlesense organsDominio espectralPhakic Refractive Lens (PRL)businesslcsh:Optics. LightOptometryJournal of Optometry
researchProduct

Optical and Visual Simulation of Standard and Modified Spherical Aberration Implantable Collamer Lens Post Myopic LASIK Surgery

2013

To evaluate the visual quality achieved in patients undergoing standard or modified implantable Collamer lens (ICL) to correct residual myopic error after laser-assisted in situ keratomileusis (LASIK) surgery.The adaptive optics visual simulator was used to simulate LASIK surgery of moderate and high myopia with a myopic regression corrected by a standard and modified ICL. Visual acuity (VA) and contrast sensitivity (CS) were measured in 14 subjects at 3- and 4.5-mm pupil. Point spread function and simulated retinal images were calculated.Comparing LASIK plus standard ICL and LASIK plus modified ICL simulations, for moderate myopia, VA improvement was less than 1 line in all VA contrasts an…

AdultMaleOptics and PhotonicsPhakic Intraocular Lensesmedicine.medical_specialtyCorneal Wavefront AberrationAdolescentgenetic structuresmedicine.medical_treatmentKeratomileusis Laser In SituVisual AcuityKeratomileusisPhakic intraocular lensContrast SensitivityYoung AdultLens Implantation IntraocularAberrometryMyopiamedicineHumansIn patientPostoperative PeriodImplantable collamer lensbusiness.industryAberrometryLASIKGeneral Medicineeye diseasesSurgeryOphthalmologySpherical aberrationOptometryFemaleLasers ExcimerbusinessEuropean Journal of Ophthalmology
researchProduct

Estimation of the mechanical properties of the eye through the study of its vibrational modes.

2017

Measuring the eye's mechanical properties in vivo and with minimally invasive techniques can be the key for individualized solutions to a number of eye pathologies. The development of such techniques largely relies on a computational modelling of the eyeball and, it optimally requires the synergic interplay between experimentation and numerical simulation. In Astrophysics and Geophysics the remote measurement of structural properties of the systems of their realm is performed on the basis of (helio-)seismic techniques. As a biomechanical system, the eyeball possesses normal vibrational modes encompassing rich information about its structure and mechanical properties. However, the integral a…

genetic structureslcsh:MedicineEyeCornea0302 clinical medicineNormal modeMedicine and Health Scienceslcsh:ScienceLens (Anatomy)PhysicsMultidisciplinaryPhysicsClassical MechanicsEye MusclesInverse problemContact Lenses Hydrophilicmedicine.anatomical_structureBiological Physics (physics.bio-ph)Physical SciencessymbolsAnatomyResearch ArticleAcousticsOcular AnatomyMaterials ScienceMaterial PropertiesFOS: Physical sciencesCondensed Matter - Soft Condensed MatterModels BiologicalVibrationResonance03 medical and health sciencessymbols.namesakeOcular SystemElastic ModulusmedicineHumansMechanical PropertiesComputer SimulationPhysics - Biological PhysicsEigenvalues and eigenvectorsComputer simulationlcsh:RFinite difference methodBiology and Life SciencesEigenvaluesPhysics - Medical PhysicsPoisson's ratioeye diseasesResonance FrequencyVibrationAlgebraLinear Algebra030221 ophthalmology & optometryEyesSoft Condensed Matter (cond-mat.soft)Human eyelcsh:QMedical Physics (physics.med-ph)sense organsHead030217 neurology & neurosurgeryMathematicsPLoS ONE
researchProduct

Changes in Accommodation and Ocular Aberration With Simultaneous Vision Multifocal Contact Lenses

2012

Objective: The aim of this study was to evaluate ocular aberration changes through different simultaneous vision multifocal contact lenses (CLs). Methods: Eighteen young-adult subjects with a mean age of 29.8 +/- 2.11 years took part. Changes in accommodative response, spherical aberration (C-4(0)), horizontal coma (C-3(1)), vertical coma (C-3(-1)), and root mean square (RMS) of higher-order aberrations (HOAs, third to sixth orders) were evaluated. Measurements were obtained with a distance-single vision CL and 2 aspheric multifocal CLs of simultaneous focus center-near design (PureVision Low Add and PureVision High Add) for 2 accommodative stimuli (-2.50 and -4.00 D). All measurements were…

AdultMaleAccommodative responseCross-Over StudiesOptical Phenomenagenetic structuresContact Lensesbusiness.industryVisual AcuityAccommodation OcularComa (optics)Mean ageRefraction Oculareye diseasesOphthalmologyOcular physiologySpherical aberrationCLs upper limitsHumansMedicineOptometryFemalebusinessAccommodationEye & Contact Lens: Science & Clinical Practice
researchProduct

Optical Quality Comparison of Conventional and Hole-Visian Implantable Collamer Lens at Different Degrees of Decentering

2012

To compare the optical quality of implantable Collamer lens (ICL) with and without central hole (Hole ICL and conventional ICL) at different degrees of decentering.Experimental laboratory investigation.Wavefront aberrations of the -3, -6, and -12 diopter (D) V4b and -3, -6, and -12 D V4c ICLs were measured in 3 conditions-centered and decentered 0.3 and 0.6 mm-at 3-mm and 4.5-mm pupils. The root mean square of total higher order aberrations, trefoil, coma, tetrafoil, secondary astigmatism, and spherical aberration were evaluated. In addition, point spread function and simulated retinal images of ICLs were calculated from the wavefront aberrations for each ICL and all conditions of decenteri…

Optics and PhotonicsPhakic Intraocular LensesCorneal Wavefront Aberrationgenetic structuresZernike polynomialsComa (optics)In Vitro TechniquesAstigmatismArtificial Lens Implant MigrationProsthesis DesignPhakic intraocular lensRetinasymbols.namesakeOpticsLens Implantation IntraocularmedicineHumansDioptreWavefrontPhysicsbusiness.industryAstigmatismModels Theoreticalmedicine.diseaseeye diseasesRefractive Surgical ProceduresOphthalmologySpherical aberrationAberrations of the eyesymbolsbusinessAmerican Journal of Ophthalmology
researchProduct

Effects of LASIK on Corneal Endothelium Using the 15-kHz IntraLase Femtosecond Laser

2011

PURPOSE: To assess the effects of LASIK with the 15-kHz IntraLase femtosecond laser on corneal endothelium. METHODS: In a prospective, single-center clinical trial, 138 patients (mean age: 32.0±7.1 years [range: 21 to 42 years]) underwent femtosecond LASIK for the correction of myopia −0.75 to −9.00 diopters (D) and cylinder up to 3.25 D. Patients were divided into two groups: contact lens group (n=76) and non-contact lens group (n=62). Pre- and 12-month postoperative specular microscopy of the central corneal endothelium was performed. The integrity of the central endothelium was assessed in terms of endothelial cell density and percentage of hexagonality. RESULTS: In the contact lens gro…

Adultmedicine.medical_specialtyCorneal endotheliumgenetic structuresEndotheliummedicine.medical_treatmentKeratomileusis Laser In SituVisual AcuityCell CountKeratomileusisRefraction OcularYoung AdultOphthalmologyMyopiamedicineHumansProspective StudiesDioptrebusiness.industryEndothelium CornealLASIKCorneal Endothelial Cell LossContact Lenses Hydrophiliceye diseasesSurgeryContact lensOphthalmologymedicine.anatomical_structureLens (anatomy)FemtosecondLasers ExcimerSurgerysense organsbusinessJournal of Refractive Surgery
researchProduct

Posterior chamber phakic intraocular lenses to improve visual outcomes in keratoconus patients

2016

The aim of this review is to summarize the results of using posterior chamber phakic intraocular lenses (pIOLs) to restore quality of vision in keratoconus patients. These pIOLs can correct the refractive errors associated with keratoconus and can also be combined with other surgical techniques to improve the results.

Phakic Intraocular Lensesmedicine.medical_specialtyKeratoconusgenetic structuresKeratoconusPhakic intraocular lens03 medical and health sciences0302 clinical medicineLens Implantation IntraocularOphthalmologyHumansMedicineLenses Intraocularbusiness.industryfungifood and beveragesRefractive Errorsmedicine.diseaseeye diseasesSensory SystemsOphthalmologyQuality of vision030221 ophthalmology & optometryOptometrySurgerysense organsbusiness030217 neurology & neurosurgeryJournal of Cataract and Refractive Surgery
researchProduct

Long-term comparison of corneal aberration changes after laser in situ keratomileusis: mechanical microkeratome versus femtosecond laser flap creatio…

2010

Purpose To compute and compare visual acuity, refractive outcomes, and anterior corneal aberration changes after myopic laser in situ keratomileusis (LASIK) with flap creation by a mechanical microkeratome and by a femtosecond laser. Setting Private practice refractive surgery center, Valencia, Spain. Design Comparative case series. Methods Patients were assigned to have LASIK flap creation with a mechanical microkeratome (Carriazo-Barraquer) or a femtosecond laser (IntraLase). The Visx S2 excimer laser was used for myopic ablation in all cases. Main outcome measures included uncorrected and corrected distance visual acuities and the defocus equivalent. Higher-order aberrations (HOAs) were …

AdultMaleVisual acuityCorneal Wavefront Aberrationgenetic structuresmedicine.medical_treatmentCorneal StromaKeratomileusis Laser In SituVisual AcuityKeratomileusisRefraction OcularSurgical FlapsYoung AdultPostoperative ComplicationsMicrokeratomeRefractive surgeryCorneamedicineMyopiaHumansProspective Studiesmedicine.diagnostic_testbusiness.industryLASIKCorneal TopographyMiddle AgedCorneal topographyeye diseasesSensory SystemsOphthalmologymedicine.anatomical_structurePrivate practiceOptometrySurgeryFemalesense organsmedicine.symptombusinessFollow-Up StudiesJournal of cataract and refractive surgery
researchProduct

Accommodative stimulus-response curves to low-pass filtered natural images

2018

To assess how the monocular steady-state accommodative stimulus-response curve is modified when viewing low-pass filtered natural images. Eighteen adult subjects participated in the study. The accommodative stimulus-response curve was objectively assessed by means of a Hartmann-Shack wavefront sensor. Measurements were taken at different accommodative demands. Target images were low-pass filtered versions of a natural image that were obtained applying different digital spatial filters that limited the spatial frequency content of the natural image. Cutoff spatial frequencies were set at 30, 21, and 15 cycles per degree (cy/deg). Mean data obtained for each target were fitted to linear model…

AdultMaleLow-pass filterRefraction Ocular050105 experimental psychologyYoung Adult03 medical and health sciencesCellular and Molecular Neuroscience0302 clinical medicineOpticsVision MonocularLinear regressionMyopiaHumansCutoff0501 psychology and cognitive sciencesMathematicsAnalysis of covarianceMonocularbusiness.industry05 social sciencesLinear modelAccommodation OcularWavefront sensorSensory SystemsOphthalmologySpace Perception030221 ophthalmology & optometryFemaleSpatial frequencybusinessPhotic StimulationGraefe's Archive for Clinical and Experimental Ophthalmology
researchProduct

Visual acuity comparison of 2 models of bifocal aspheric intraocular lenses.

2008

Purpose To compare visual acuity after bilateral implantation of 2 models of multifocal aspheric intraocular lenses (IOLs). Setting Fernandez-Vega Ophthalmological Institute, Oviedo, and University of Valencia, Valencia, Spain. Methods Prospective study of patients who had bilateral implantation of an AcrySof ReSTOR SN6AD3 IOL (Group 1) or an Acri.LISA 366D IOL (Group 2). Six months postoperatively, binocular uncorrected and best corrected distance visual acuity, uncorrected-distance and best distance-corrected near visual acuity, best corrected intermediate visual acuity, and the defocus curve were measured in both IOL groups. Results Group 1 comprised 36 eyes (18 patients) and Group 2, 40…

Malemedicine.medical_specialtyVisual acuityDistance visual acuitygenetic structuresPseudophakiamedicine.medical_treatmentAcrylic ResinsVisual AcuityIntraocular lensProsthesis DesignNear visual acuityFunctional LateralityNear acuityLens Implantation IntraocularOphthalmologymedicineHumansProspective StudiesDioptreAgedLenses IntraocularDepth PerceptionVision BinocularPhacoemulsificationbusiness.industryMiddle Agedeye diseasesSensory SystemsOphthalmologyIntraocular lensesIntermediate visual acuityOptometrySurgeryFemalemedicine.symptombusinessJournal of cataract and refractive surgery
researchProduct

Iris-fixated toric phakic intraocular lens for myopic astigmatism

2011

Purpose To evaluate the efficacy, predictability, safety, stability, and complications of the Artiflex toric iris-fixated phakic intraocular lens (pIOL) for myopic astigmatism. Setting Private practice surgery centers, Valencia and Terrassa, Spain. Design Cohort study. Methods At 12 months, refraction, uncorrected (UDVA) and corrected (CDVA) distance visual acuities, complications, pIOL misalignment, and endothelial cell count (ECC) were evaluated. Indices of success and misalignment were calculated using vector analysis. Results The study enrolled 42 eyes in 25 patients aged 21 to 39 years. The mean spherical equivalent decreased from −8.85 diopters (D) ± 2.71 (SD) to −0.37 ± 0.46 D, with …

AdultMalePhakic Intraocular Lensesmedicine.medical_specialtyVisual acuitygenetic structuresVisual AcuityIrisAstigmatismRefraction OcularPhakic intraocular lensCohort StudiesMyopic astigmatismYoung AdultPostoperative ComplicationsLens Implantation IntraocularOphthalmologyMyopiamedicineHumansIris (anatomy)Dioptremedicine.diagnostic_testbusiness.industrySuture TechniquesAstigmatismCorneal TopographyCorneal topographymedicine.diseaseeye diseasesSensory SystemsOphthalmologyTreatment Outcomemedicine.anatomical_structurePrivate practiceFemaleSurgerymedicine.symptombusinessFollow-Up StudiesJournal of Cataract and Refractive Surgery
researchProduct

Effect of contact lenses on ocular biometric measurements based on swept-source optical coherence tomography

2019

ABSTRACT Purpose: To determine the reliability of swept- source optical coherence tomography in cases in which soft contact lenses cannot be removed when acquiring biometric measurements. Methods: Eight subjects were included and only one eye per participant was analyzed. Each eye was measured six times by swept-source optical coherence tomography with the IOLMaster 700 instrument (Carl Zeiss Meditec, Jena, Germany). Axial length, central corneal thickness, anterior chamber depth, lens thickness, and keratometric measurements were evaluated for the naked eye and while wearing soft contact lenses of three different powers (-1.5, -3.0, and +2.0 D). Results: There were statistically significan…

AdultBiometryMaterials sciencegenetic structuresContact LensesTomography optical coherenceStatistics Nonparametriclaw.invention03 medical and health sciences0302 clinical medicineOpticslcsh:OphthalmologyOptical coherence tomographyLens thicknessAnterior Eye SegmentReference ValueslawmedicineHumansContact lensesAnalysis of VarianceCross-Over Studiesmedicine.diagnostic_testbusiness.industryReproducibility of ResultsGeneral MedicineAxial lengtheye diseasesContact lensLens (optics)Axial Length EyeOphthalmologylcsh:RE1-994Reference values030221 ophthalmology & optometrysense organsTomographybusinessTomography Optical CoherenceArquivos Brasileiros de Oftalmologia
researchProduct

On-eye optical quality of daily disposable contact lenses for different wearing times

2012

Purpose To quantify the optical quality of various daily disposable contact lenses in vivo and to ascertain its variation in terms of wearing time by means of objective non-invasive determination of wavefront patterns. Methods The crx1 adaptive-optics system was used to measure the wavefront aberrations in 15 myopic eyes before and at 2-h intervals after contact lens fitting, over a 12-h wearing period. Seven types of contact lenses having different material, water content and lens design were evaluated in this study: Dailies Total1, Dailies AquaComfort Plus, Proclear 1 Day, 1-Day Acuvue TruEye, 1-Day Acuvue moist, SofLens daily disposable and Clariti 1-Day. The aberration data were analyse…

AdultMalePoint spread functionOptics and PhotonicsCorneal Wavefront AberrationTime Factorsgenetic structuresZernike polynomialsVisual AcuityPupillaw.inventionYoung Adultsymbols.namesakeOpticslawOptical transfer functionAberrometryMyopiaHumansDisposable EquipmentMathematicsWavefrontbusiness.industryAberrometryContact Lenses Hydrophiliceye diseasesSensory SystemsLens (optics)OphthalmologysymbolsFemalesense organsSpatial frequencybusinessOptometryOphthalmic and Physiological Optics
researchProduct

Comparison of two artificial tear formulations for dry eye through high‐resolution optical coherence tomography

2011

Purpose:  The aim was to determine the efficacy of two artificial eye-drop formulations by analysing the lower tear film meniscus volume through a commercial high-resolution spectral-domain optical coherence tomographer. Methods:  Twenty dry eye patients (12 men, eight women, aged 57.5 ± 8.4 years) with refractive errors from -2.50 to +0.75 D (mean -1.34 ± 1.02 D) and cylinders lower than 1.00 D were examined. Tear meniscus volume was measured before, immediately after and 10, 30 and 60 minutes after instillation using the Copernicus high-resolution spectral-domain optical coherence tomographer (Optopol Tech SA, Zawiercie, Poland). Volume was calculated from the local area obtained from tom…

Malemedicine.medical_specialtyDrug Compoundingmedicine.medical_treatmentDry Eye SyndromesHigh resolutionMeniscus (anatomy)Young AdultOptical coherence tomographyReference ValuesOphthalmologymedicineHumansSurface Tensionmedicine.diagnostic_testbusiness.industryImage Enhancementeye diseasesSurgeryOphthalmologyArtificial tearsmedicine.anatomical_structureVolume (thermodynamics)TearsTearsDry Eye SyndromesFemalesense organsEyelidOphthalmic SolutionsbusinessTomography Optical CoherenceFollow-Up StudiesOptometryClinical and Experimental Optometry
researchProduct

Visual and optical performance with hybrid multifocal intraocular lenses

2010

During the past years, the wish to become independent of spectacles has been growing among cataract and presbyopic patients due to many factors, such as the increase in near visual demands, the aesthetic need for a spectacle-free image and ageing of refractive surgery patients, among others. This review assesses recently published studies that analyse visual and optical performance through different metrics of eyes implanted with multifocal intraocular lenses (IOLs), particularly hybrid IOL designs. The published evidence suggests that hybrid multifocal IOLs provide very good outcomes in a number of visual and optical performance parameters. Patients implanted with this type of IOL obtain a…

Intraocular LensesOptical PerformanceVisual acuitygenetic structuresCompensation Comparisonmedicine.medical_treatmentKeratomileusis Laser In SituVisual AcuityMethodKeratomileusislaw.inventionGlareLensTratamiento médicoSensitivitylawRefractive surgeryMedicineContrast (vision)MonovisionPostoperative Periodmedia_commonVistaLenses IntraocularMultifocalsGlare (vision)Equipment DesignRefractive ErrorsLens (optics)Bilateral ImplantationApodized Diffractive IolOftalmologíamedicine.symptommedicine.medical_specialtyIn-Situ KeratomileusisRefractivemedia_common.quotation_subjectHigh-Order AberrationsContrast SensitivityOphthalmologyAberrometryClinical-OutcomesHumansRetinal StraylightDepth Perceptionbusiness.industryAberrometryMultifocal intraocular lensContrasteye diseasesOphthalmologyOptometrysense organsbusinessOptometry
researchProduct

“In situ” corneal and contact lens thickness changes with high resolution OCT

2012

Purpose: To show the utility of high resolution spectral domain optical coherence tomography (HR SOCT) for the in situ evaluation of epithelial, stromal and contact lens (CL) thickness changes under closed-eye conditions without lens removal. Settings: Clinical and Experimental Optometry Research Lab, University of Minho, Portugal. Methods: Eight young healthy patients wore a thick soft CL during 90 minutes under closed-eye conditions and measures of epithelial and stromal corneal thickness were obtained at regular intervals using a HR SOCT (Copernicus HR, Optopol Tech. SA, Poland). Results: Minimal changes in epithelial thickness were detected with a transient statistically significant inc…

Corneacontact lensesScience & Technologygenetic structuresOCTepithelial thicknessCoherence tomographysense organsedemaeye diseasesstromal thickness
researchProduct

Optical performance of two new trifocal intraocular lenses: through-focus modulation transfer function and influence of pupil size

2013

Background To compare the in vitro optical quality of two new trifocal intraocular lenses at different focal points as a function of pupil size. Methods Two intraocular lenses having different design approaches were evaluated: the AT LISA tri 839MP with a trifocal diffractive design, and the FineVision, which combines two distinct apodized bifocal diffractive profiles resulting in three foci. A PMTF optical bench was used to assess the intraocular lenses' performance, and as optical quality metrics, the through-focus modulation transfer function was selected; that is, it was measured at 10 focal points and for four different apertures (2.0, 3.0, 3.75 and 4.5 mm). Results For both lenses, th…

OphthalmologyFocal pointCardinal pointOpticsIntraocular lensesApodizationFocus (geometry)business.industryOptical transfer functionPupil sizeMedicinebusinessPupilClinical & Experimental Ophthalmology
researchProduct

Effect of Multizone Refractive Multifocal Contact Lenses on Standard Automated Perimetry

2012

PURPOSE The aim of this study was to evaluate whether the creation of 2 foci (distance and near) provided by multizone refractive multifocal contact lenses (CLs) for presbyopia correction affects the measurements on Humphreys 24-2 Swedish interactive threshold algorithm (SITA) standard automated perimetry (SAP). METHODS In this crossover study, 30 subjects were fitted in random order with either a multifocal CL or a monofocal CL. After 1 month, a Humphrey 24-2 SITA standard strategy was performed. The visual field global indices (the mean deviation [MD] and pattern standard deviation [PSD]), reliability indices, test duration, and number of depressed points deviating at P<5%, P<2%, P<1%, an…

Malemedicine.medical_specialtygenetic structuresContact LensesOpticsCLs upper limitsPattern standard deviationOphthalmologymedicineHumansMathematicsCross-Over Studiesbusiness.industryAutomated perimetryPresbyopiaPresbyopiaMiddle Agedmedicine.diseaseRefractive lensCrossover studyeye diseasesVisual fieldAbsolute deviationOphthalmologySensory ThresholdsVisual Field TestsFemaleVisual FieldsbusinessAlgorithmsEye &amp; Contact Lens: Science &amp; Clinical Practice
researchProduct

Effect of partial and full correction of corneal spherical aberration on visual acuity and contrast sensitivity

2008

A 60-year-old white man had cataract surgery with an AcrySof IQ intraocular lens (IOL) implanted in the right eye and a Tecnis IOL implanted in the left eye. The ocular spherical aberration (SA) target for a 6.0 mm pupil was +0.10 microm for the right eye and 0 microm for the left eye. After surgery, the ocular SA in the right eye was significantly higher than that in the left eye (+0.112 microm +/- 0.002 [SD] versus +0.021 +/- 0.003 microm; P.001). No between-eye difference in the best corrected visual acuity and photopic contrast sensitivity was found. The contrast sensitivity was significantly better in the eye with the AcrySof IQ IOL at 12 and 18 cpd under mesopic conditions. The best c…

Malemedicine.medical_specialtyVisual acuityPseudophakiagenetic structuresmedicine.medical_treatmentmedia_common.quotation_subjectVisual AcuityIntraocular lensPupilContrast SensitivityCorneaLens Implantation IntraocularOphthalmologyCorneamedicineHumansContrast (vision)media_commonPhacoemulsificationbusiness.industryMiddle AgedCataract surgeryRefractive Errorseye diseasesSensory SystemsOphthalmologyLeft eyeSpherical aberrationmedicine.anatomical_structureSurgerysense organsmedicine.symptombusinessJournal of Cataract and Refractive Surgery
researchProduct

Optical power distribution of refractive and aspheric multifocal contact lenses: Effect of pupil size

2015

Abstract Purpose To evaluate the power profile within the optic zone of different designs of multifocal contact lenses (CLs) and to analyze how the effect of pupil size could impact on their optical performance. Methods The optical power distribution within the optic zones of multifocal CLs was measured by the Nimo TR1504 (LAMBDA-X, Belgium). The multifocal CLs under study were the Acuvue Bifocal, the Acuvue Oasys for Presbyopia, the PureVision Multifocal and the PureVision 2 for Presbyopia. Each design was considered in all their available addition powers. All lenses had a nominal power of −3.0D. At the same time, three lenses of each model were considered and five consecutive readings of …

Materials scienceLightContact LensesPupil diameterIrisOptical powerlaw.inventionCLs upper limitsOpticslawmedicineHumansScattering Radiationbusiness.industryPupil sizeEquipment DesignPresbyopiaGeneral MedicinePresbyopiamedicine.diseaseRefractionEquipment Failure AnalysisLens (optics)RefractometryOphthalmologybusinessOptometryContact Lens and Anterior Eye
researchProduct

Intraocular Telescopic System Design: Optical and Visual Simulation in a Human Eye Model

2016

Purpose. To design an intraocular telescopic system (ITS) for magnifying retinal image and to simulate its optical and visual performance after implantation in a human eye model. Methods. Design and simulation were carried out with a ray-tracing and optical design software. Two different ITS were designed, and their visual performance was simulated using the Liou-Brennan eye model. The difference between the ITS was their lenses’ placement in the eye model and their powers. Ray tracing in both centered and decentered situations was carried out for both ITS while visual Strehl ratio (VSOTF) was computed using custom-made MATLAB code. Results. The results show that between 0.4 and 0.8 mm of d…

Article Subjectbusiness.industryRetinal damageComputingMethodologies_IMAGEPROCESSINGANDCOMPUTERVISIONStrehl ratioMatlab codeRetinal image03 medical and health sciencesOphthalmology0302 clinical medicinemedicine.anatomical_structurelcsh:Ophthalmologylcsh:RE1-994030221 ophthalmology & optometryMedicineSoftware designSystems designRay tracing (graphics)Computer visionHuman eyeArtificial intelligencebusiness030217 neurology & neurosurgeryResearch ArticleJournal of Ophthalmology
researchProduct

Visual function after bilateral implantation of a new zonal refractive aspheric multifocal intraocular lens.

2011

Purpose To evaluate visual function after bilateral implantation of a zonal refractive aspheric multifocal intraocular lens (IOL). Setting Private practice surgery center, Valencia, Spain. Design Cohort study. Methods Consecutive eyes with cataract had bilateral implantation of Lentis Mplus LS-312 multifocal IOLs. Distance, intermediate, and near visual acuities; contrast sensitivity; defocus curves; and a quality-of-vision questionnaire, including presence of halos or dysphotopsia, were evaluated 6 months postoperatively. A control group of age-matched monofocal pseudophakic patients was included to compare contrast sensitivity function. Results In the multifocal group, the mean binocular …

Malemedicine.medical_specialtygenetic structuresPseudophakiaMesopic visionmedia_common.quotation_subjectmedicine.medical_treatmentVision DisordersVisual AcuityIntraocular lensProsthesis DesignCohort StudiesContrast SensitivityLens Implantation IntraocularOphthalmologySurveys and QuestionnairesmedicineContrast (vision)HumansProspective Studiesmedia_commonAgedLenses IntraocularVision BinocularPhacoemulsificationbusiness.industryGlare (vision)PhacoemulsificationMultifocal intraocular lensMiddle Agedeye diseasesSensory SystemsOphthalmologyPrivate practiceQuality of LifeOptometrySurgeryFemalesense organsbusinessPhotopic visionJournal of cataract and refractive surgery
researchProduct

Refractive and Visual Results after Implantation of the AcrySof ReSTOR IOL in High and Low Hyperopic Eyes

2009

To assess the differences in refractive and visual results obtained in eyes with high and low hyperopia after implantation of a multifocal intraocular lens (IOL).A prospective study was performed on 172 hyperopic eyes implanted with the AcrySof Re-STOR Natural (SN60D3) IOL. Two groups were created, high and low hyperopes (86 eyes in both cases). We analyzed monocular visual acuity for distance and near, with and without distance correction. Photopic and mesopic contrast sensitivity (CS) were also assessed. All measurements were performed at 6 months after surgery.Monocular best distance-corrected visual acuity was 0.01+/-0.03 logMAR for low hyperopes and 0.04+/-0.10 logMAR for high hyperope…

Malemedicine.medical_specialtyVisual acuityPseudophakiagenetic structuresVisual AcuityProsthesis DesignRefraction Ocular03 medical and health sciences0302 clinical medicineLens Implantation IntraocularOphthalmologyHumansMedicineProspective StudiesAgedLenses IntraocularPhacoemulsificationbusiness.industryGeneral MedicineMiddle AgedMultifocal intraocular lenseye diseasesOphthalmologyHyperopia030221 ophthalmology & optometryFemalesense organsmedicine.symptombusiness030217 neurology & neurosurgeryEuropean Journal of Ophthalmology
researchProduct

Stereoacuity After Refractive Lens Exchange With AcrySof ReSTOR Intraocular Lens Implantation

2009

Purpose: To evaluate stereoacuity before and after refractive lens exchange (RLE) with AcrySof ReSTOR intraocular lens (IOL) implantation. Methods: Stereoacuity was measured using the Titmus stereotest at 40 cm under photopic conditions (85 cd/m 2 ) before and after RLE with bilateral AcrySof ReSTOR Natural (SN60D3 model) implantation in 30 hyperopic eyes of presbyopes with low astigmatism (⩽1.00 diopter [D]). Stereoacuity measurements after implantation were compared with those found before surgery. Results: Stereoacuity was unchanged after RLE with pseudoaccommodative IOL implantation. In this population of non-cataractous hyperopes with excellent preoperative stereoacuity (46.42±1.36 se…

Malemedicine.medical_specialtyVisual acuitygenetic structuresmedicine.medical_treatmentPopulationVisual AcuityIntraocular lensAstigmatismOpticsLens Implantation IntraocularOphthalmologymedicineHumanseducationDioptreLenses IntraocularDepth PerceptionVision Binoculareducation.field_of_studyPhacoemulsificationbusiness.industryPresbyopiaPresbyopiaPhacoemulsificationMiddle Agedmedicine.diseaseeye diseasesStereoscopic acuityOphthalmologyHyperopiaFemaleSurgerymedicine.symptombusinessJournal of Refractive Surgery
researchProduct

Schematic eye models to mimic the behavior of the accommodating human eye

2018

A simplified version of the human eye is known as schematic eye model. Since the first attempts in the middle of the 19th century, numerous approaches describing new schematic eye models have been introduced. Some of them are able to describe the accommodation ability of the human eye. Accommodative schematic eyes could be of great interest since they are able to explain the functionality of the human eye and they can be easily used for different research purposes. Some of these include the design and testing of multifocal ophthalmic solutions, evaluation of the effect of optical aberrations on the retinal image quality, and study of the optical performance of the eye at different distances…

genetic structuresComputer scienceComputingMethodologies_IMAGEPROCESSINGANDCOMPUTERVISIONSchematic eyeModels Biological01 natural sciencesCornea010309 optics03 medical and health sciencesOcular physiology0302 clinical medicine0103 physical sciencesmedicineHumansbusiness.industryAccommodation OcularSchematicSurgical proceduresÒpticaRefractive ErrorsSensory SystemsRetinal imageeye diseasesOphthalmologymedicine.anatomical_structureIntraocular lenses030221 ophthalmology & optometryOptometrySurgeryHuman eyesense organsbusinessAccommodationUlls
researchProduct

Retinal Straylight Before and After Penetrating Keratoplasty in an Eye with a Post-Herpetic Corneal Scar

2008

Objetivo: Estudio in vivo de la luz dispersa que alcanza la retina en un paciente antes y despues de someterse a una queratoplastia penetrante (o sus siglas en ingles, PKP). Metodos: En un paciente varon de 65 anos con una ulcera corneal herpetica se midio la proporcion de luz dispersa que alcanza la retina tanto antes como despues de una PKP, utilizando para ello un metodo psicometrico denominado "de comparacion por compensacion" («Compensation comparison method», C-Quant straylightmeter, Oculus GmbH, Alemania). Resultados: La cantidad de luz dispersa que alcanza la retina medida antes de la cirugia fue elevada en comparacion con los valores obtenidos en estudios previos en sujetos normale…

luz dispersa que llega a la retina0303 health sciencesmedicine.medical_specialtyretinal straylightvisual performancegenetic structuresbusiness.industryCase Reportkeratoplastycalidad visualeye diseasesqueratoplastia03 medical and health sciences0302 clinical medicinelcsh:Ophthalmologylcsh:RE1-994Ophthalmology030221 ophthalmology & optometrymedicinelcsh:QC350-467businesslcsh:Optics. LightCorneal Scar030304 developmental biologyOptometryJournal of Optometry
researchProduct

Visual performance of two simultaneous vision multifocal contact lenses

2012

Purpose To evaluate and compare the visual performance of two simultaneous vision multifocal contact lenses (CLs). Methods In this cross-over study design 20 presbyopic subjects were fitted with two different simultaneous vision multifocal CLs (the PureVision Multifocal Low Add and Acuvue Oasys for Presbyopia) in random order. After 1 month, binocular distance visual acuity (BDVA) under photopic (85 cd/m2) and mesopic (3 cd/m2) conditions, binocular near visual acuity (BNVA), binocular distance contrast sensitivity function (CSF) under photopic and mesopic conditions, binocular near CSF and defocus curve were measured. Subjects were then refitted with the alternative correction and the proc…

AdultMaleVisual acuitygenetic structuresContact LensesMesopic visionmedia_common.quotation_subjectVisual Acuitylaw.inventionContrast SensitivitylawmedicineHumansContrast (vision)media_commonVision BinocularCross-Over Studiesbusiness.industryIntermediate distanceBoth lensesPresbyopiaPresbyopiaMiddle Agedmedicine.diseaseeye diseasesSensory SystemsLens (optics)OphthalmologyOptometryFemalemedicine.symptombusinessOptometryPhotopic visionOphthalmic and Physiological Optics
researchProduct

Aspheric intraocular lenses enhance contrast sensitivity

2007

Evaluation of: Pandita D, Raj SM, Vasavada VA, Vasavada VA, Kazi NS, Vasavada AR. Contrast sensitivity and glare disability after implantation of AcrySof IQ natural aspherical intraocular lens: pro...

medicine.medical_specialtybusiness.industrymedicine.medical_treatmentmedia_common.quotation_subjectBiomedical EngineeringIntraocular lensCataract surgeryOphthalmologyIntraocular lensesGlare disabilityOphthalmologyQuality of visionOptometryMedicineContrast (vision)businessOptometrymedia_commonExpert Review of Ophthalmology
researchProduct

Visual performance with simultaneous vision multifocal contact lenses.

2011

Purpose:  The aim was to assess visual performance after PureVision high addition multifocal contact lens (PM) fitting through contrast sensitivity measured under different illumination levels for both distance and near. Methods:  In a cross-over study, 20 presbyopic patients were randomly assigned to PM or spectacles. Near contrast sensitivity was measured with the Vistech VCTS 6500 system. Distance contrast sensitivity and distance visual acuity (VA) were measured with the Functional Vision Analyser under photopic (85 cd/m2) and mesopic (3.0 cd/m2) conditions, the latter also under two levels of induced glare: 1.0 lux and 28 lux. Near VA was measured by logMAR charts under approximately 8…

Adultmedicine.medical_specialtyDistance visual acuitygenetic structuresMesopic visionContact Lensesmedia_common.quotation_subjectVisual AcuityContrast SensitivityOpticsOphthalmologymedicineContrast (vision)Humansmedia_commonMathematicsMonocularCross-Over Studiesbusiness.industryGlare (vision)Accommodation OcularPresbyopiaEquipment DesignPresbyopiaMiddle Agedmedicine.diseaseeye diseasesContact lensOphthalmologyTreatment OutcomebusinessOptometryPhotopic visionFollow-Up StudiesClinicalexperimental optometry
researchProduct

Agreement of white-to-white measurements with the IOLMaster 700, Atlas 9000, and Sirius systems

2018

Current advances in ocular surgery require the evaluation of differences in automated white-to-white (WTW) measurements between systems. We aim to analyze three different commonly used devices in clinical practice: the IOLMaster 700, the Atlas 9000, and the Sirius.Ninety right eyes of ninety healthy subjects were included. Measurements of WTW distances were taken with each device for all subjects in the same session and by the same observer. Statistical comparison was carried out by means of the rANOVA procedure and the Bonferroni post-hoc test. In addition, the Bland-Altman analysis was applied in order to perform pairwise comparisons.Average WTW values obtained by the IOLMaster 700, the A…

AdultMaleWhite to whitebusiness.industryOcular surgerySiriusBiomedical EngineeringOphthalmologic Surgical ProceduresGeneral MedicineMiddle AgedYoung Adult03 medical and health sciences0302 clinical medicinemedicine.anatomical_structureAtlas (anatomy)030221 ophthalmology & optometrymedicineHumansOptometryFemaleSurgerybusiness030217 neurology & neurosurgeryOphthalmologic Surgical ProcedureDemographyExpert Review of Medical Devices
researchProduct

Proclear EP vs placebo: visual outcomes and symptoms of asthenopia in nonpresbyopes and early presbyopes

2011

Purpose: Over the past 20 years, many studies have reported the success of multifocal contact lenses (MFCLs) compared to monovision (MV), with only partial success being reported for MFCLs. Chronologically it appears there has been a gradual improvement in the performance of MFCLs. This study investigated whether this change in success is reflected in clinical practice. Method: Lens fit data collected from 2005 to 2009 by the International Contact Lens Prescribing Survey Consortium was reviewed for patients over 45 years old. A similar survey conducted from 1988 to 1989 was also reviewed and compared. Twelve published (Pubmed.gov) reports of clinical trials involving MFCLs and MV were revie…

medicine.medical_specialtygenetic structuresbusiness.industryGeneral MedicinePlaceboeye diseasesContact lensClinical trialClinical PracticeOphthalmologyPhysical therapymedicineOptometryContact lensesbusinessOptometryContact Lens and Anterior Eye
researchProduct

Optical quality of the eye after lens replacement with a pseudoaccommodating intraocular lens

2007

To examine the optical quality of healthy presbyopic eyes before and after implantation of the pseudoaccommodating AcrySof ReSTOR Natural intraocular lens (IOL) (Alcon Laboratories) by measuring visual acuity and wavefront aberrations.University of Valencia, Fernández-Vega Ophthalmological Institute, Valencia, Spain.Monocular refraction and photopic distance (6 m) and near (0.33 m) visual acuities were determined before and after clear lens extraction with bilateral AcrySof ReSTOR Natural IOL implantation in 30 hyperopic eyes (+0.50 to +4.00 diopters [D]) of presbyopic patients with low astigmatism (or = 1.00 D). Postsurgical binocular visual acuity was measured over a range of effective di…

Malemedicine.medical_specialtyVisual acuityPseudophakiagenetic structuresmedicine.medical_treatmentVisual AcuityIntraocular lensAstigmatismProsthesis DesignPupillaw.inventionContrast SensitivityLens Implantation IntraocularlawOphthalmologyLens CrystallinemedicineHumansDioptreLenses IntraocularVision BinocularPhacoemulsificationbusiness.industryAccommodation OcularPresbyopiaPhacoemulsificationMiddle Agedmedicine.diseaseeye diseasesSensory SystemsLens (optics)OphthalmologyHyperopiaOptometryFemaleSurgerysense organsmedicine.symptombusinessPhotopic visionJournal of Cataract and Refractive Surgery
researchProduct

Lack of effect of intraocular lens asphericity on visual performance with acrylic intraocular lenses.

2011

Purpose. To determine whether implantation of acrylic intraocular lens (IOL) with aspheric design (Tecnis Z9003, AMO) results in improved visual acuity or contrast sensitivity compared with conventional spherical acrylic IOL (AR40e, AMO). Methods. In an intraindividual randomized prospective study of 60 patients with bilateral cataract, the Tecnis Z9003 IOL was compared with the AR40e IOL. Ocular aberrations for a 4.0-mm pupil and 6.0-mm pupil were measured with a Hartmann-Shack aberrometer. Quality of vision was measured using visual acuity and contrast sensitivity under mesopic and photopic conditions. Results. Eyes with the Tecnis Z9003 IOL had significantly less spherical aberration and…

Malemedicine.medical_specialtyOptics and PhotonicsVisual acuityMesopic visionmedicine.medical_treatmentmedia_common.quotation_subjectAcrylic ResinsVisual AcuityIntraocular lensProsthesis DesignPupilContrast SensitivityLens Implantation IntraocularOphthalmologyMedicineContrast (vision)Humansmedia_commonAgedAged 80 and overLenses Intraocularbusiness.industryStrehl ratioGeneral MedicineMiddle AgedOphthalmologySpherical aberrationFemalemedicine.symptombusinessPhotopic visionEuropean journal of ophthalmology
researchProduct

Optical quality comparison among different Boston contact lens materials.

2014

BACKGROUND The aim was to assess the optical quality of four Boston contact lens materials with an optical device based on Schlieren interferometry. METHODS The NIMO TR1504 (Lambda-X, Nivelles, Belgium) was used to measure higher-order aberrations and their corresponding root mean square values of four different rigid gas permeable contact lenses made from four different Boston materials: EO, ES, XO and XO2 . For each lens, 30 measurements were performed with two optical apertures: 3.0 mm and 6.0 mm. The modulation transfer function, point spread function, Strehl ratio and a simulation of the image provided by the lens were computed from the Zernike coefficients measured up to the fourth or…

Materials sciencebusiness.industryApertureContact LensesStrehl ratio02 engineering and technology021001 nanoscience & nanotechnologylaw.inventionRoot mean squareContact lensLens (optics)03 medical and health sciencesOphthalmologyInterferometry0302 clinical medicineOpticslawSchlierenOptical transfer function030221 ophthalmology & optometry0210 nano-technologybusinessOptometryClinicalexperimental optometry
researchProduct

Reliability results of straylight measurements using the C-Quant

2008

Purpose Assessment of repeatability and reproducibility of straylight measures with the C-Quant straylightmeter (Oculus AG, Germany), effect of age on reliability measures and correlation of measures determined with new methods of scatter determination. Methods Results from different studies will be presented. For repeatability assessment, 20 eyes (age 26.9±2.7 years) were examined with the C-Quant, taking 10 consecutive readings. 5 subjects were also examined on 5 consecutive days to assess reproducibility. Repeated measures from 84 subjects, age range 19-86 years, were analysed to assess the effect of patient’s age. Software was developed to quantify scatter from centroid patterns obtaine…

Reproducibilitymedicine.medical_specialtybusiness.industryHealthy subjectsRepeated measures designSmall sampleGeneral MedicineRepeatabilityAudiologyCorrelationOphthalmologyOpticsmedicinebusinessReliability (statistics)Acta Ophthalmologica
researchProduct

In vitro optical performance of nonrotational symmetric and refractive-diffractive aspheric multifocal intraocular lenses: impact of tilt and decentr…

2012

Purpose To evaluate the optical quality of Acrysof Restor SN6AD1 refractive–diffractive +3.00 D and Lentis Mplus LS-312 nonrotational symmetric +3.00 D aspheric multifocal intraocular lenses (IOLs) and analyze the effect of tilt and decentration. Setting University of Valencia, Valencia, and University of Murcia, Murcia, Spain. Design Experimental study. Methods An artificial model eye was used to measure wavefront aberrations of both IOL models. The modulation transfer function (MTF) and point-spread function (PSF) were calculated for a 5.0 mm pupil and under 5 situations: centered, 0.2 mm and 0.4 mm decentered, and 2 degrees and 4 degrees tilted. Results The refractive–diffractive IOL had…

WavefrontPhysicsLenses IntraocularOptics and Photonicsbusiness.industryAberrometryMultifocal intraocular lensModels TheoreticalArtificial Lens Implant MigrationProsthesis DesignRefraction OcularRefractionSensory SystemsCycles per degreeOphthalmologyOpticsTilt (optics)Optical transfer functionAberrometryOptometryHumansSurgerySpatial frequencybusinessJournal of cataract and refractive surgery
researchProduct

Visual quality differences between orthokeratology and LASIK to compensate low-moderate myopia.

2013

PURPOSE: To assess the differences in visual performance between orthokeratology (ortho-k) and laser in situ keratomileusis (LASIK) for the treatment of low-to-moderate myopia. METHODS: An adaptive optics visual simulator (Imagine Eyes) was used to simulate the wavefront aberration patterns induced by ortho-k and LASIK for low and moderate myopia on 10 healthy eyes. Visual acuity (VA) at 100%, 50%, and 10% contrast levels and contrast sensitivity (CS) at 10, 20 and 25 cycles per degree (cpd) were then measured for 3- and 6-mm pupil sizes. RESULTS: Differences in VA for 3-mm pupil diameter were not found between ortho-k and LASIK. For 6-mm pupil size, LASIK provided significantly better VA v…

AdultMalemedicine.medical_specialtyVisual acuitymedicine.medical_treatmentmedia_common.quotation_subjectKeratomileusis Laser In SituVisual AcuityKeratomileusisPupilCycles per degreeContrast SensitivityYoung AdultOphthalmologyMyopiaMedicineContrast (vision)Humansmedia_commonAnalysis of Variancebusiness.industryOrthokeratologyPupil sizeLASIKOphthalmologyFemalemedicine.symptombusinessOrthokeratologic ProceduresCornea
researchProduct

Artiflex Toric Phakic Intraocular Lens Implantation in Congenital Nystagmus

2011

Case: A 44-year-old woman with congenital nystagmus and myopic astigmatism in both eyes who was submitted to phakic intraocular lens (pIOL) implantation. Methods: Full ophthalmologic examination including refractive status, corrected (CDVA) and uncorrected (UCVA) monocular and binocular visual acuities, ocular motility, slit-lamp evaluation, tonometry and fundoscopy before and after implantation of toric pIOLs (Artiflex; Ophtec BV, The Netherlands) in both eyes. Results: Preoperative logMAR CDVA were 0.699 and 0.420 in the right and left eye, respectively. Three months after surgery, logMAR UCVA were 0.398 and 0.182, reaching binocular logMAR UCVA of 0.132. There were no changes in nystagmu…

medicine.medical_specialtygenetic structuresbusiness.industrymedicine.medical_treatmentToric phakic intraocular lensNystagmusPhakic intraocular lenseye diseasesMyopic astigmatismOphthalmologyLeft eyeNystagmuslcsh:OphthalmologyOphthalmologic examinationlcsh:RE1-994OphthalmologyRefractive surgeryMedicineIn patientPublished: August 2011sense organsmedicine.symptomRefractive surgerybusinessCongenital nystagmusCase Reports in Ophthalmology
researchProduct

Accommodation in human eye models: a comparison between the optical designs of Navarro, Arizona and Liou-Brennan.

2017

Aim To simulate and compare accommodation in accommodative and non-accommodative human eye models. Methods Ray tracing and optical design program was used. Three eye models were designed and studied: the Navarro, the Arizona and the Liou-Brennan. In order to make the Navarro and Liou-Brennan models to accommodate, specific geometric parameters of the models were altered with values that were chosen from the literature. For the Arizona model, its' mathematical functions for accommodation were used for the same accommodative demands. The simulation included four distances of accommodation for each model: at infinity, 3, 1 and 0.5 m.The results were diffraction images of a "letter F" for graph…

DiffractionZernike polynomialsbusiness.industryMathematical analysis01 natural sciences010309 opticsRoot mean squareOphthalmologysymbols.namesakemedicine.anatomical_structureBasic ResearchOptical transfer function0103 physical sciencessymbolsAiry diskMedicineOptometryHuman eyeRay tracing (graphics)businessAccommodationInternational journal of ophthalmology
researchProduct

Contrast sensitivity after refractive lens exchange with diffractive multifocal intraocular lens implantation in hyperopic eyes

2008

Contrast Test chart at distance and near under 3 luminance levels (85.0 cd/m 2 , 5.0 cd/m 2 , and 2.5 cd/m 2 ) before and after RLE with bilateral AcrySof ReSTOR IOL implantation in 30 hyperopic eyes with presbyopia and low astigmatism (%1.0 diopter). Results after surgery were compared with those before surgery. RESULTS: Six months postoperatively, the mean residual spherical equivalent refractive error was 0.21 diopter G 0.19 (SD). The best corrected distance and near visual acuities were comparable to those before surgery. For distance vision, the safety index was 1.02 and the efficacy index was 0.91. For near vision, the values were 1.04 and 1.02, respectively. There were no statistical…

Refractive errormedicine.medical_specialtygenetic structuresbusiness.industrymedia_common.quotation_subjectmedicine.medical_treatmentIntraocular lensPresbyopiaMultifocal intraocular lensAstigmatismmedicine.diseaseeye diseasesSensory SystemsVision disorderOphthalmologyOphthalmologymedicineContrast (vision)Surgerymedicine.symptombusinessDioptremedia_commonJournal of Cataract and Refractive Surgery
researchProduct

In vitro power profiles of daily disposable contact lenses

2012

Abstract Purpose To evaluate and compare the distribution of refractive power within the optic zone of different soft contact lenses and to investigate the effect of lens decentration on the power profiles. Methods The Nimo TR1504 instrument was used to measure the optical power across different aperture diameters (from 1.5 mm to 5.5 mm in steps of 0.5 mm) of four daily disposable contact lenses: DAILIES TOTAL1, Proclear 1-Day, SofLens daily disposable and 1-DAY ACUVUE MOIST. Measurements were performed using a wet cell. Power data were evaluated when contact lenses were in its centered position and after inducing different amounts of lens decentration (from 0.2 mm to 1.0 mm in steps of 0.2…

Materials scienceContact LensesAperturebusiness.industryOptical powerEquipment DesignGeneral Medicinelaw.inventionPower (physics)Equipment Failure AnalysisLens (optics)Contact lensOphthalmologyOpticslawDaily disposablesense organsBack vertex powerDisposable EquipmentbusinessDioptreOptometryContact Lens and Anterior Eye
researchProduct

Changes in the anterior chamber during accommodation assessed with a Scheimpflug system.

2014

Purpose To study changes in the anterior chamber depth (ACD), anterior chamber angle, and pupil diameter with accommodation. Setting University of Valencia, Valencia, Spain. Design Evaluation of diagnostic technology. Methods A rotating Scheimpflug camera (Pentacam HR) was used to measure changes in the ACD, anterior chamber angle, and pupil diameter with accommodation. Peripheral ACD was measured at the corneal center and 2.0 mm away from it in the nasal, superior, temporal, and inferior directions. The anterior chamber angle was computed as the mean anterior chamber angle of the entire eye. All measurements were obtained with accommodation stimuli ranging from +1.0 to −4.0 diopters (D) in…

AdultMalemedicine.medical_specialtyDesign evaluationAnterior ChamberScheimpflug principlePupil diameterDiagnostic Techniques OphthalmologicalAnterior chamber angleYoung AdultOphthalmologyDiagnostic technologymedicinePhotographyHumansPentacam hrDioptrebusiness.industryAccommodation OcularPupilSensory SystemsOphthalmologyOptometrySurgeryFemalesense organsbusinessAccommodationJournal of cataract and refractive surgery
researchProduct

In vitro power profiles of multifocal simultaneous vision contact lenses.

2013

Abstract Purpose To evaluate the power profile of multifocal contact lenses (CLs) using a new technology based on quantitative deflectometry. Methods The Nimo TR1504 was used to analyze the power distribution of multifocal CLs. The CLs under study were: Air Optix Aqua Multifocal Low, Medium and High Addition and Focus Progressives. Three lenses of each model were considered. Results All multifocal CLs showed a power profile characterized by a change toward more positive power values when aperture sizes become smaller. The near refractive addition of the lenses under study was +2.61 D, +1.44 D, +1.30 D and +0.30 D for the Focus Progressives, the Air Optix Aqua Multifocal High, Medium Add and…

PhysicsLightbusiness.industryApertureContact LensesOptical powerGeneral MedicinePresbyopiaEquipment Designmedicine.diseaseDistance correctionlaw.inventionPower (physics)Lens (optics)Equipment Failure AnalysisOphthalmologyRefractometryOpticslawmedicineScattering RadiationbusinessFocus (optics)OptometryNominal power (photovoltaic)Contact lensanterior eye : the journal of the British Contact Lens Association
researchProduct

Device interchangeability on anterior chamber depth and white-to-white measurements: a thorough literature review

2016

We have reviewed a set of recently published studies that compared the anterior chamber depth (ACD) and/or white-to-white (WTW) distance obtained by means of different measuring devices. Since some of those studies reached contradictory conclusions regarding device interchangeability, this review was carried out in attempting to clarify which clinical devices can or cannot be considered as interchangeable in clinical practice to measure ACD and/or WTW distance, among these devices: A-scan, ultrasound biomicroscopy, Orbscan and Orbscan II (Bausch&Lomb Surgical Inc., San Dimas, California, USA), Pentacam and Pentacam HR (Oculus, Wetzlar, Germany), Galilei (Ziemer, Switzerland), Visante optica…

White to whitemedicine.medical_specialtybusiness.industryReviewClinical Practice03 medical and health sciencesOphthalmologyAlcon LaboratoriesAnterior chamber eye0302 clinical medicineOphthalmology030221 ophthalmology & optometryMedicineOptometryOrbscan iiPentacam hrbusiness030217 neurology & neurosurgeryInternational Journal of Ophthalmology
researchProduct

OCT for Assessing Artificial Tears Effectiveness in Contact Lens Wearers

2011

PURPOSE: To apply a commercially available high-resolution spectral domain optical coherence tomographer (SOCT) to assess the change in tear volume after application of a new artificial tears formulation specifically developed for contact lens (CL) users. METHODS: Twenty OD from young healthy CL wearers (mean age, 24.7 ± 3.5 years) with refractive errors ranging from -0.75 to -2.50 D (mean, -1.56 ± 0.69 D) were examined. All subjects were fitted with Focus Dailies CL (Ciba Vision), and two drops of Blink Contacts (AMO), lubricating formulation specifically developed for CL wearers, were instilled after baseline measures. Tear meniscus volume (TMV) was measured immediately after and 1 min, 1…

Adultmedicine.medical_specialtyContact Lensesmedicine.medical_treatmentMeniscus (anatomy)Tear volumeYoung AdultRegular distributionOphthalmologyImage Processing Computer-AssistedHumansMedicinebusiness.industryRepeated measures designContact Lenses HydrophilicRefractive ErrorsContact lensOphthalmologyArtificial tearsmedicine.anatomical_structureTear meniscusOftalmologíaDry Eye SyndromesEyelidOphthalmic SolutionsbusinessTomography Optical CoherenceFollow-Up StudiesOptometryOptometry and Vision Science
researchProduct

In vitro optical quality differences between multifocal apodized diffractive intraocular lenses.

2013

Purpose To compare the in vitro optical quality of multifocal apodized intraocular lenses (IOLs) at different focal points. Setting University of Valencia, Valencia, Spain. Design Experimental study. Methods The Acrysof Restor +3.0 diopter (D) multifocal IOL with 2 main foci (bifocal IOL) and the Finevision multifocal IOL with 3 main foci (trifocal IOL) were evaluated. The optical quality was quantified using the modulation transfer function (MTF) at 7 focal points and for 3.0 mm and 4.5 mm apertures. The through-focus MTF at 10 focal points of the IOLs was also recorded. Results For the 0.0 D and −2.5 D focal points, the bifocal IOL showed the highest MTF values for pupil sizes as well as …

PhysicsLenses IntraocularFocal pointOptics and Photonicsbusiness.industryApertureProsthesis DesignSensory SystemsOptical qualityOphthalmologyOpticsCardinal pointApodizationIntraocular lensesOptical transfer functionSurgeryVisual FieldsbusinessDioptreVision OcularJournal of cataract and refractive surgery
researchProduct

Implantable collamer lens and femtosecond laser for myopia: comparison using an adaptive optics visual simulator.

2014

Purpose: To compare optical and visual quality of implantable collamer lens (ICL) implantation and femtosecond laser in situ keratomileusis (F-LASIK) for myopia. Methods: The CRX1 adaptive optics visual simulator (Imagine Eyes, Orsay, France) was used to simulate the wavefront aberration pattern after the two surgical procedures for -3-diopter (D) and -6-D myopia. Visual acuity at different contrasts and contrast sensitivities at 10, 20, and 25 cycles/degree (cpd) were measured for 3-mm and 5-mm pupils. The modulation transfer function (MTF) and point spread function (PSF) were calculated for 5-mm pupils. Results: F-LASIK MTF was worse than ICL MTF, which was close to diffraction-limited MT…

Point spread functionAdultLaser de excimerPhakic Intraocular LensesVisual acuityVisual acuitymedicine.medical_treatmentKeratomileusis Laser In SituLentes intraoculares; Sensibilidade de contrasteVisual AcuityCeratomileuse assistida por excimer laser in situ/métodosKeratomileusisPhakic intraocular lensMyopia/surgeryPupilKeratomileusis laser in situ/methodsContrast SensitivityYoung Adultlcsh:OphthalmologyLens Implantation IntraocularOptical transfer functionmedicineMyopiaHumansComputer SimulationContrast sensitivityAdaptive opticsSimulationPhysicsLasers excimer/therapeutic useAcuidade visualAberrometryAccommodation OcularGeneral MedicineOphthalmologyTreatment Outcomelcsh:RE1-994Lenses intraocularMiopia/cirurgiaOptometrySpatial frequencymedicine.symptomArquivos brasileiros de oftalmologia
researchProduct

Posterior chamber phakic intraocular lenses after penetrating keratoplasty.

2009

Purpose To evaluate the efficacy, predictability, and safety of a phakic posterior chamber intraocular Collamer lens (ICL) after penetrating keratoplasty (PKP). Setting Fernandez-Vega Ophthalmological Institute, Oviedo, Spain. Methods A myopic or toric ICL was implanted after PKP in eyes unable to wear glasses or contact lenses and for which corneal laser surgery was contraindicated. The uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), refractive error, and endothelial cell count were recorded preoperatively and 24 months postoperatively. Results Preoperatively, the 15 eyes had myopia from −2.00 to −17.00 diopters (D) or astigmatism from −1.50 to −7.00 D. …

Laser surgeryAdultMaleRefractive errormedicine.medical_specialtyPhakic Intraocular Lensesgenetic structuresmedicine.medical_treatmentVisual AcuityIntraocular lensCell CountAstigmatismPhakic intraocular lensSafety indexPostoperative ComplicationsLens Implantation IntraocularRefractive surgeryOphthalmologymedicineMyopiaHumansProspective StudiesDioptrebusiness.industryEndothelium CornealAstigmatismMiddle Agedmedicine.diseaseeye diseasesSensory SystemsOphthalmologyTreatment OutcomeSurgeryFemalesense organsbusinessKeratoplasty PenetratingJournal of cataract and refractive surgery
researchProduct

Optical quality comparison between 2 collagen copolymer posterior chamber phakic intraocular lens designs

2014

Purpose To compare the optical quality in vitro of 2 designs of the Visian Implantable Collamer Lens phakic intraocular lens (pIOL) for different powers and optical apertures. Setting University of Valencia, Valencia, Spain. Design Experimental study. Methods The Nimo TR1504 deflectometry device was used to measure the V4c pIOL, which has a smaller optic diameter, and the V5 pIOL, which has a larger optic diameter. The pIOLs were measured for −3.00 diopters (D), −6.00 D, −9.50 D, and −10.50 D at different optical apertures from 3.00 to 6.00 mm depending on the IOL power and model. The root mean square of higher-order aberrations (RMS HOAs) was analyzed. The Strehl ratio, point-spread functi…

WavefrontOptics and PhotonicsPhakic Intraocular LensesMaterials sciencePolymersApertureZernike polynomialsbusiness.industryStrehl ratioPupilProsthesis DesignRefraction OcularPhakic intraocular lensSensory SystemsRoot mean squareOphthalmologySpherical aberrationsymbols.namesakeOpticssymbolsHumansSurgeryCollagenbusinessDioptreJournal of Cataract and Refractive Surgery
researchProduct

Visual and optical performance with the ReZoom multifocal intraocular lens

2011

Purpose This study evaluated visual acuity, contrast sensitivity, and wavefront aberrations after refractive multifocal intraocular lens (IOL) implantation. Methods A prospective study comprising 174 eyes of 87 patients who had bilateral implantation of a multifocal IOL was carried out. A control group of 100 eyes of 50 age-matched patients with a monofocal IOL was used for comparison. Uncorrected and corrected distance and near visual acuity, contrast sensitivity (CS), and wavefront analysis (Hartmann-Shack) was performed 6 months after surgery. Contrast sensitivity was tested for distance and near under mesopic (2 cd/m2) and photopic conditions (90 cd/m2). Results Distance photopic CS was…

Malemedicine.medical_specialtyCorneal Wavefront AberrationVisual acuityPseudophakiagenetic structuresmedia_common.quotation_subjectVisual AcuityProsthesis DesignRefraction OcularContrast SensitivityLens Implantation IntraocularOphthalmologymedicineHumansContrast (vision)Prospective StudiesAgedmedia_commonAged 80 and overLenses IntraocularWavefrontVision Binocularbusiness.industryAberrometryGeneral MedicineMiddle AgedMultifocal intraocular lenseye diseasesOphthalmologyFemalemedicine.symptombusinessEuropean Journal of Ophthalmology
researchProduct

Single versus double femtosecond laser pass for incomplete laser in situ keratomileusis flap in contralateral eyes: Visual and optical outcomes

2011

Purpose To evaluate visual acuity, refractive outcomes, and anterior corneal higher-order aberrations (HOAs) after myopic laser in situ keratomileusis (LASIK) with uneventful single femtosecond laser pass versus double pass performed for intraoperative suction loss. Setting Private refractive surgery center, Valencia, Spain. Design Cohort study. Methods After the LASIK flap was created with a single pass of an Intralase femtosecond laser in 1 eye and a double pass in the fellow eye, the ablation was performed with a Visx S2 laser. At 12 months, the refraction, uncorrected (UDVA) and corrected (CDVA) distance visual acuities, and anterior corneal HOAs were measured with 4.0 mm and 6.0 mm pup…

AdultMalemedicine.medical_specialtyCorneal Wavefront AberrationVisual acuitygenetic structuresCorneal Stromamedicine.medical_treatmentKeratomileusis Laser In SituVisual AcuityKeratomileusisRefraction OcularSurgical Flapslaw.inventionCohort StudiesYoung AdultlawRefractive surgeryOphthalmologyMyopiamedicineHumansDioptreRetrospective Studiesbusiness.industryLASIKMiddle AgedLaserAblationeye diseasesSensory SystemsSurgeryOphthalmologyTreatment OutcomeFemtosecondFemaleLasers ExcimerSurgerysense organsmedicine.symptombusinessJournal of Cataract and Refractive Surgery
researchProduct

The effect of simulated normal and amblyopic higher-order aberrations on visual performance.

2012

Purpose To study the effect of simulated amblyopic and normal higher-order aberrations on visual performance of normal eyes. Methods To assess visual function, an adaptive optics visual simulator was used to compensate volunteers' ocular aberrations and simulate the wavefront aberration patterns found in healthy and amblyopic eyes in 7 healthy individuals. Visual acuity for high (100%), medium (50%), and low (10%) contrast and contrast sensitivity at 10, 20, and 25 cycles per degree (cpd) were measured after simulation of both pattern aberrations. The modulation transfer function and the point spread function were computed based on the aberration data. All measures were taken for 3 and 5.5 …

Adultmedicine.medical_specialtyVisual acuityCorneal Wavefront Aberrationgenetic structuresmedia_common.quotation_subjectVisual AcuityAmblyopiaPupilContrast SensitivityYoung AdultOphthalmologyOptical transfer functionmedicineContrast (vision)Humansmedia_commonContrast levelbusiness.industryAberrometryPupil sizeAstigmatismPupilModels TheoreticalRefractive Errorseye diseasesOphthalmologyAberrations of the eyePediatrics Perinatology and Child HealthOptometrysense organsSpatial frequencymedicine.symptombusinessJournal of AAPOS : the official publication of the American Association for Pediatric Ophthalmology and Strabismus
researchProduct

Optical quality in eyes with aspheric intraocular lenses and in younger and older adult phakic eyes: comparative study.

2009

To compare ocular higher-order aberrations (HOAs) in eyes with aspheric intraocular lenses (IOL) and in phakic eyes.Department of Ophthalmology, Military Health Service Institute, Warsaw, Poland.Higher-order aberrations with a 5.0 mm pupil and best spectacle-corrected visual acuity (BSCVA) were analyzed in a young phakic group (age 20 to 40 years), older phakic group (age 40 to 60 years), and a pseudophakic group (age 62 to 84 years; SN60WF aspheric IOL).The mean coma was 0.13 microm+/-0.07 (SD) in the younger phakic group, 0.18+/-0.08 microm in the older phakic group, and 0.16+/-0.08 microm in the pseudophakic group; the difference between the 2 phakic groups was statistically significant …

AdultMalemedicine.medical_specialtyAgingVisual acuitygenetic structuresPseudophakiamedicine.medical_treatmentVisual AcuityIntraocular lensProsthesis DesignPupilContrast SensitivityYoung AdultLens Implantation IntraocularOphthalmologyLens CrystallinemedicineHumansAgedComaAged 80 and overLenses IntraocularPhacoemulsificationbusiness.industryPhacoemulsificationMiddle Agedeye diseasesSensory SystemsOphthalmologySpherical aberrationIntraocular lensesOptometrySurgeryFemalesense organsmedicine.symptombusinessPseudophakiaJournal of cataract and refractive surgery
researchProduct

Contrast sensitivity loss in the peripheral visual field following laser in situ keratomileusis.

2007

We report a case of contrast sensitivity loss in the peripheral visual field following laser in situ keratomileusis (LASIK). A 50-year-old white man was referred to us for differences in visual perception in the peripheral field between the right eye, which had had LASIK, and the left eye, which was emmetropic. Linear meridional static perimetry was carried out in the 0- to 180-degree meridian using a Goldmann perimeter to assess the peripheral perimetric thresholds. There was a statistically significantly marked increased threshold in contrast sensitivity in the nasal and temporal fields from 40 degrees of eccentricity in the LASIK eye compared with that in the emmetropic eye. Eyes treated…

MaleVisual acuitygenetic structuresEye diseasemedicine.medical_treatmentKeratomileusis Laser In SituVision DisordersVisual AcuityEmmetropiaKeratomileusisContrast SensitivityMedicineHumansmedicine.diagnostic_testbusiness.industryLASIKCorneal TopographyMiddle AgedCorneal topographymedicine.diseaseeye diseasesSensory SystemsVisual fieldOphthalmologyMeridian (perimetry visual field)OptometryVisual Field TestsSurgerysense organsmedicine.symptomVisual FieldsbusinessJournal of cataract and refractive surgery
researchProduct

The posterior chamber phakic refractive lens (PRL): a review

2012

Implantation of phakic intraocular lenses (pIOLs) is a reversible refractive procedure, preserving the patient’s accommodative function with minimal induction of higher order aberrations compared with corneal photoablative procedures. Despite this, as an intraocular procedure, it has potential risks such as cataracts, chronic uveitis, pupil ovalization, corneal endothelial cell loss, pigmentary dispersion syndrome, pupillary block glaucoma, astigmatism, or endophthalmitis. Currently, only two models of posterior chamber pIOLs are commercially available, the implantable collammer lens (STAAR Surgical Co.) and the phakic refractive lens (PRL; Zeiss Meditec). The number of published reports on…

Phakic Intraocular Lensesmedicine.medical_specialtygenetic structuresmedicine.medical_treatmentVisual performanceOptical qualityReviewAstigmatismRefraction OcularPhakic intraocular lensPhakic refractive lens (PRL)CataractPupilEndophthalmitisLens Implantation IntraocularCataractsOphthalmologyRefractive surgeryMyopiamedicineHumansRefractive surgeryÓpticaPosterior chamber phakic intraocular lensbusiness.industryPatient SelectionEquipment Designmedicine.diseaseeye diseasesOphthalmologyAberrations of the eyemedicine.anatomical_structureLens (anatomy)Posterior Capsule of the LensOptometrysense organsbusinessEye
researchProduct

Stereoacuity with balanced presbyopic contact lenses.

2010

Our aim was to evaluate near stereoacuity with the balanced Proclear Multifocal simultaneous vision contact lens. Twenty-five presbyopic subjects were fitted binocularly with the Proclear Multifocal contact lens and with distance contact lenses combined with reading spectacles, which served as controls. After one month, stereoacuity was measured using the vectographic Titmus and Random dot stereotests and the Howard-Dolman (HD) apparatus under photopic conditions (85 cd/m(2) ) at 40 cm. Binocular high-contrast visual acuities (BHCVA) at distance and near were examined. For the multifocal group, mean stereoacuity with the Howard-Dolman method was 22.40 ± 8.23 seconds of arc. Using the Titmus…

MaleVisual acuitygenetic structuresContact LensesVisual AcuityContrast SensitivitymedicineHumansVision testDepth PerceptionVision BinocularVision TestsPresbyopiaEquipment DesignPresbyopiaMiddle Agedmedicine.diseaseeye diseasesStereoscopic acuityOphthalmologyEyeglassesReadingOftalmologíaOptometryFemalemedicine.symptomDepth perceptionPsychologyBinocular visionOptometryClinicalexperimental optometry
researchProduct

Repeatability assessment of biometric measurements with different refractive states and age using a swept-source biometer

2018

Background We aim to assess if refractive error or age may influence the repeatability of measurements using a swept-source biometer. Methods A total of 61 subjects were evaluated with IOLMaster 700 acquiring measurements of axial length (AL), central corneal thickness (CCT), white-to-white distance (WTW), anterior aqueous depth (AQD), lens thickness (LT), and keratometry (K) readings. Repeatability was evaluated classifying the sample according to the refractive state and age by the calculation of the within-subject standard deviation (Sw), coefficient of repeatability, and intraclass correlation coefficient. Results Very similar Sw was acquired among groups for AL, CCT, and WTW. Differenc…

AdultMaleAgingRefractive errormedicine.medical_specialtyBiometryIntraclass correlationBiomedical Engineering030204 cardiovascular system & hematologyAstigmatismStandard deviationlaw.inventionYoung Adult03 medical and health sciences0302 clinical medicineLens thicknessAge groupslawOphthalmologyLens CrystallinemedicineHumansMathematicsKeratometerAge FactorsReproducibility of ResultsGeneral MedicineRepeatabilityMiddle AgedRefractive Errorsmedicine.diseaseAxial Length EyeFemaleSurgeryTomography Optical Coherence030217 neurology & neurosurgeryExpert Review of Medical Devices
researchProduct

Visual function after implantation of an aspheric bifocal intraocular lens.

2009

Purpose To evaluate distance, intermediate, and near vision after bifocal aspheric AcrySof ReSTOR SN6AD1 intraocular lens (IOL) implantation. Setting Fernandez-Vega Ophthalmological Institute, Oviedo, Spain. Methods Binocular distance best corrected visual acuity (BCVA) (4.0 m), best distance-corrected near (40.0 cm) and intermediate (70.0, 60.0, 50.0 cm) acuities, and contrast sensitivity under photopic (85.0 candelas [cd]/m 2 ) and mesopic (3.0 cd/m 2 ) conditions with and without glare were measured postoperatively. A patient-satisfaction and visual phenomena questionnaire was administered. Results Six months postoperatively, the mean acuities (logMAR) were binocular BCVA, −0.064 ± 0.049…

Malemedicine.medical_specialtygenetic structuresMesopic visionmedia_common.quotation_subjectmedicine.medical_treatmentVisual AcuityIntraocular lensProsthesis DesignContrast SensitivityLens Implantation IntraocularOphthalmologySurveys and QuestionnairesMedicineContrast (vision)HumansProspective StudiesDioptremedia_commonAgedLenses IntraocularVision BinocularPhacoemulsificationbusiness.industryGlare (vision)Middle Agedeye diseasesSensory SystemsOphthalmologyPatient SatisfactionVisual DisturbanceOptometrySurgeryFemaleSpatial frequencybusinessPhotopic visionJournal of cataract and refractive surgery
researchProduct

Visual simulation through an aspheric aberration-correcting intraocular lens in subjects with different corneal profiles using adaptive optics.

2013

The aim of this study was to analyse the visual quality of the AcrySof IQ SN60WF® intraocular lens (IOL) when combined with different corneal profiles. Ten eyes of 10 participants with no prior history of refractive or cataract surgery were evaluated. An adaptive optics visual simulator was used to simulate the wavefront aberration pattern of an aspheric aberration-correcting IOL (AcrySof IQ SN60WF®). Normal corneas (group A), low and high myopic corneal ablations (groups B and C, respectively) and low and high hyperopic corneal ablations (groups D and E, respectively) were also simulated. Monocular distance visual acuities at 100, 50 and 10 per cent of contrast were measured. At 100, 50 an…

AdultCorneal Wavefront Aberrationgenetic structuresComputer sciencebusiness.industrymedicine.medical_treatmentVisual AcuityIntraocular lenseye diseasesOphthalmologySpherical aberrationOpticsLens Implantation IntraocularmedicineMyopiaOptometryOftalmologíaHumanssense organsbusinessAdaptive opticsOptometryÓpticaClinicalexperimental optometry
researchProduct

Stereoacuity with simultaneous vision multifocal contact lenses.

2010

Our purpose was to evaluate near stereoacuity (SA) with Focus Progressives and PureVision Multifocal simultaneous vision contact lenses. In a cross-over study design, 20 presbyopic subjects were fitted with either the Focus Progressives or PureVision Multifocal lenses. After 1 month, SA was measured with the vectographic Titmus, Random dot stereotests, and the Howard-Dolman apparatus under photopic conditions (85 lux) at 40 cm. Binocular high-contrast visual acuity at distance and near was examined. Subjects were then refitted with the alternative correction and the procedure was repeated. Mean SA with the Focus Progressive was 21 +/- 7 sec arc, 54 +/- 17 sec arc, and 51 +/- 21 sec arc, wit…

Malebusiness.product_categoryVisual acuitygenetic structuresContact LensesLentes de contactoVisual AcuityMedicineHumansVision testMultifocal lensesDepth PerceptionCross-Over Studiesbusiness.industryVision TestsEquipment DesignPresbyopiaMiddle AgedStereoscopic acuityOphthalmologyOptometryOftalmologíaFemalemedicine.symptomDepth perceptionbusinessOptometryOptometry and vision science : official publication of the American Academy of Optometry
researchProduct

Crystalens HD Intraocular Lens Analysis Using an Adaptive Optics Visual Simulator

2013

PURPOSE To compare visual and optical quality of the Crystalens HD intraocular lens (IOL) with that of a monofocal IOL. METHODS The wavefront aberration patterns of the monocular Akreos Adapt AO IOL and the single-optic accommodating Crystalens HD IOL were measured in a model eye. The Crystalens IOL was measured in its nonaccommodative state and then, after flexing the haptic to produce 1.4 mm of movement, in its accommodative state. Using an adaptive optics system, subjects' aberrations were removed and replaced with those of pseudophakes viewing with either lens. Monocular distance visual acuity (DVA) at high (100%), medium (50%), and low (10%) contrast and contrast sensitivity (CS) were …

AdultMalePoint spread functionOptics and PhotonicsDepth of focusmedicine.medical_specialtymedicine.medical_treatmentVisual AcuityIntraocular lensProsthesis Designlaw.inventionContrast SensitivityYoung AdultOpticslawOptical transfer functionOphthalmologymedicineHumansComputer SimulationAdaptive opticsLenses IntraocularPhysicsDepth PerceptionMonocularbusiness.industryAccommodation OcularStrehl ratioLens (optics)OphthalmologyFemalebusinessOptometryOptometry and Vision Science
researchProduct

Interchangeability among five devices that measure anterior eye distances.

2014

The aim was to study the interchangeability of various devices that measure anterior chamber depth (ACD) and white-to-white (WTW) distance.Eighty right eyes of eighty patients aged 20 to 40 years were included. Their spherical equivalent ranged from -4.25 to +1.00 dioptres. Each eye's ACD and the WTW distance were measured using the following devices: a Castroviejo surgical calliper, CA-200F Corneal Analyser, Orbscan II, Pentacam HR and IOLMaster 500.The Pentacam HR measured significantly greater ACD (p0.01) than the other two devices, whereas IOLMaster 500 and Orbscan II yielded comparable (p0.01) distances. Nonetheless, in every device comparison, the mean difference was within clinically…

AdultMaleBiometrybusiness.industryAnterior ChamberMeasure (physics)Corneal TopographyReproducibility of ResultsEquipment DesignRefraction OcularRefractive ErrorsInterchangeabilityCorneaOphthalmologyYoung AdultOpticsOptometryMedicineHumansFemaleProspective StudiesbusinessOptometryFollow-Up StudiesClinicalexperimental optometry
researchProduct

Visual quality comparison of conventional and Hole-Visian implantable collamer lens at different degrees of decentering

2013

Purpose To compare the visual quality of implantable collamer lens (ICL) with and without central hole (Hole ICL and conventional ICL) at different degrees of decentering. Methods An adaptive optics visual simulator (crx1, Imagine Eyes, Orsay, France) was used to simulate the –3, –6 and –12 dioptres (D) conventional and Hole ICLs in three conditions: centred and decentred 0.3 and 0.6 mm. Visual acuity (VA) at high-contrast, medium-contrast and low-contrast and contrast sensitivity (CS) were measured in 15 observers for 3 and 4.5 mm pupils. Results No statistically significant differences in VA and CS were found between conventional and Hole ICLs for any ICL powers and pupil sizes evaluated …

AdultMaleOptics and PhotonicsPhakic Intraocular LensesVisual acuitymedia_common.quotation_subjectVisual AcuityPupilContrast SensitivityYoung AdultCellular and Molecular NeuroscienceQuality (physics)Lens Implantation IntraocularMyopiamedicineHumansContrast (vision)media_commonImplantable collamer lensbusiness.industryAberrometrySensory SystemsOphthalmologyOptometryFemalemedicine.symptombusinessBritish Journal of Ophthalmology
researchProduct

Assessment of corneal thickness and tear meniscus during contact-lens wear

2014

To assess the effect of seven different daily disposable contact lenses upon corneal thickness, as well as upon tear meniscus volume, by using optical coherence tomography (OCT).Thirty-four young healthy subjects wore seven different types of daily disposable soft contact lenses, each for a period of 12h: Delefilcon A, Nelfilcon A, Omafilcon A, Filcon II3, Narafilcon A, Etafilcon A and Hilafilcon B. Central and mid-peripheral corneal thickness and lower tear meniscus volume (TMV) were measured using an OCT device during contact-lens wear at 4-h intervals throughout a 12-h period. Measurements were also recorded without any contact lenses being worn during a day.In the no-lens scenario a sma…

AdultMalemedicine.medical_specialtyMaterials sciencegenetic structuresSurface PropertiesCorneaYoung AdultOptical coherence tomographyOphthalmologyCorneaMyopiamedicineHumansmedicine.diagnostic_testHealthy subjectsGeneral MedicineContact Lenses Hydrophiliceye diseasesContact lensOphthalmologyTear meniscusmedicine.anatomical_structureTearsTearsFemaleDaily disposablesense organsTomography Optical CoherenceOptometryContact Lens and Anterior Eye
researchProduct

Simulated prototype of posterior chamber phakic intraocular lens for presbyopia correction.

2014

Purpose To evaluate the visual impact of adding different spherical aberration values to an Implantable Collamer Lens phakic intraocular lens (pIOL) to increase the depth of focus using an adaptive optics visual simulator. Setting University of Valencia, Valencia, Spain. Design Experimental study. Methods Wavefront aberrations in −3.00 D and −6.00 diopter (D) pIOLs were measured in vitro. Afterward, different simulated pIOL experimental prototypes were created along with variances in the spherical aberration. An adaptive optics visual simulator was used to simulate vision after the implantation of the different pIOL prototypes from their wavefront aberrations. The corrected distance visual …

AdultDepth of focusPhakic Intraocular LensesVisual acuityCorneal Wavefront Aberrationgenetic structuresVisual AcuityDiagnostic Techniques OphthalmologicalPhakic intraocular lensProsthesis DesignYoung AdultLens Implantation IntraocularmedicineHumansComputer SimulationAdaptive opticsDioptreMathematicsWavefrontDepth PerceptionPupilPresbyopiaPresbyopiamedicine.diseaseeye diseasesSensory SystemsOphthalmologySpherical aberrationOptometrySurgerysense organsmedicine.symptomJournal of cataract and refractive surgery
researchProduct

Visual Performance of Four Simultaneous-Image Multifocal Contact Lenses Under Dim and Glare Conditions

2014

To assess and compare the effects of four simultaneous-image multifocal contact lenses (SIMCLs), and those with distant-vision-only contact lenses on visual performance in early presbyopes, under dim conditions, including the effects of induced glare.In this double-masked crossover study design, 28 presbyopic subjects aged 40 to 46 years were included. All participants were fitted with the four different SIMCLs (Air Optix Aqua Multifocal [AOAM; Alcon], PureVision Multifocal [PM; BauschLomb], Acuvue Oasys for Presbyopia [AOP; JohnsonJohnson Vision], and Biofinity Multifocal [BM; CooperVision]) and with monofocal contact lenses (Air Optix Aqua, Alcon). After 1 month of daily contact lens wear…

AdultMalegenetic structuresContact LensesComputer scienceCrossoverVisual AcuityGlareContrast SensitivityOpticsDouble-Blind MethodHumansLightingAnalysis of VarianceCross-Over Studiesbusiness.industryGlare (vision)PresbyopiaMiddle AgedCrossover studyeye diseasesOphthalmologyOptometryFemalesense organsbusinessEye &amp; Contact Lens: Science &amp; Clinical Practice
researchProduct

Optical Quality Comparison between Spherical and Aspheric Toric Intraocular Lenses

2014

Purpose To measure and compare the optical quality of spherical and aspheric toric intraocular lenses (IOLs). Methods Wavefront aberrations of AcrySof Toric and IQ Toric IOLs (Alcon Laboratories) for different powers were measured at 3- and 5-mm pupils by Nimo TR0805 instrument. The Zernike coefficients of trefoil, coma, tetrafoil, secondary astigmatism, and spherical aberration were evaluated. The point spread functions (PSFs) of each IOL evaluated were calculated from the wavefront aberrations. The PSF images also were calculated from the IOL wavefront aberrations, adding the cornea's aberrations to simulate the optical quality after their implantation. Results Spherical toric IOLs showed…

Lenses IntraocularWavefrontPhysicsOptics and PhotonicsCorneal Wavefront Aberrationbusiness.industryZernike polynomialsAberrometryAstigmatismComa (optics)General MedicineModels TheoreticalOptical qualityOphthalmologyAlcon LaboratoriesSpherical aberrationsymbols.namesakeOpticsLens Implantation IntraocularIntraocular lensesAberrometrysymbolsHumansbusinessEuropean Journal of Ophthalmology
researchProduct

Effect of age in the ciliary muscle during accommodation: Sectorial analysis

2017

Abstract Purpose To compare changes in the ciliary muscle area at different sectors between pre-presbyopic and presbyopic eyes during accommodation by means of an anterior segment optical coherence tomographer (OCT). Methods The anterior ciliary muscle area was measured in 20 healthy and phakic pre-presbyopic eyes, whose mean age was 23.3 ± 4.4 years, and in 20 healthy and phakic presbyopic eyes, whose mean age was 46.5 ± 5.2 years. The relative change in the cross-sectional area of the ciliary muscle was measured at the nasal, inferior, and temporal sectors between 0 and −3 D of vergence, in −1 D step. A linear model was used to assess the correlation of each eye parameter with the accommo…

AdultMaleAgingOriginal articleAccommodationmedicine.medical_specialtyAdolescentPopulationVergenceRefraction OcularYoung Adult03 medical and health sciences0302 clinical medicineCiliary bodyOphthalmologyHumansMedicineAcomodacióneducationPresbiciaMúsculo ciliarAnalysis of Varianceeducation.field_of_studyOptical coherence tomographybusiness.industryCiliary BodyBiomechanicsAccommodation OcularAnterior segmentMean agePresbyopiaPresbyopiaMiddle Agedmedicine.diseaseTomografía de coherencia ópticaCiliary muscleCiliary musclemedicine.anatomical_structure030221 ophthalmology & optometryFemaleSegmento anteriorsense organsbusinessAccommodationTomography Optical Coherence030217 neurology & neurosurgeryOptometryJournal of Optometry
researchProduct

Effect of Phenylephrine on the Accommodative System

2016

Accommodation is controlled by the action of the ciliary muscle and mediated primarily by parasympathetic input through postganglionic fibers that originate from neurons in the ciliary and pterygopalatine ganglia. During accommodation the pupil constricts to increase the depth of focus of the eye and improve retinal image quality. Researchers have traditionally faced the challenge of measuring the accommodative properties of the eye through a small pupil and thus have relied on pharmacological agents to dilate the pupil. Achieving pupil dilation (mydriasis) without affecting the accommodative ability of the eye (cycloplegia) could be useful in many clinical and research contexts. Phenylephr…

genetic structuresArticle Subjectsense organseye diseasesJournal of Ophthalmology
researchProduct

Effect of contact lenses on ocular biometric measurements based on swept-source optical coherence tomography

2019

ABSTRACT Purpose: To determine the reliability of swept- source optical coherence tomography in cases in which soft contact lenses cannot be removed when acquiring biometric measurements. Methods: Eight subjects were included and only one eye per participant was analyzed. Each eye was measured six times by swept-source optical coherence tomography with the IOLMaster 700 instrument (Carl Zeiss Meditec, Jena, Germany). Axial length, central corneal thickness, anterior chamber depth, lens thickness, and keratometric measurements were evaluated for the naked eye and while wearing soft contact lenses of three different powers (-1.5, -3.0, and +2.0 D). Results: There were statistically significan…

genetic structuressense organseye diseases
researchProduct

In vivo OCT assessment of anterior segment central axial lengths with accommodation

2017

ABSTRACT Purpose: To assess changes in anatomic structures in the anterior eye segment in terms of axial lengths with accommodation via optical coherence tomography. Methods: In this observational study, 25 eyes of 25 healthy adults were examined using the Visante® omni optical coherence tomography system. Central corneal thickness, anterior chamber depth, central lens thickness, and anterior segment length were assessed. The evaluated parameters were obtained with accommodation using different stimulus vergences, namely 0.0, -1.0, -2.0, and -3.0 D. Variation of these parameters was compared among different levels of accommodation. Results: Central corneal thickness was not altered at any s…

researchProduct

Multisectorial changes in the ciliary muscle during accommodation measured with high-resolution optical coherence tomography

2019

ABSTRACT Purpose: To measure changes in the anterior ciliary muscle during accommodation at the nasal, superior, temporal, and inferior sectors by means of an anterior chamber optical coherence tomographer, and correlate them with vergence changes. Methods: Twenty-four subjects with healthy, phakic eyes, whose mean age was 27.1 ± 8.9 years, underwent measurement with an anterior chamber optical coherence tomographer. The anterior ciliary muscle was measured at the nasal, temporal, superior, and inferior sectors for 0, -1, -2, and -3 D of vergence. A linear model was used to assess the correlation of each eye parameter with the accommodative demand. Results: The anterior ciliary muscle area …

sense organs
researchProduct

Artificial pupil versus contralateral balanced contact lens fit for presbyopia correction

2018

Purpose: To assess and compare the effects of contact lens-based artificial pupil design and contralateral balanced multifocal contact lens combination (CBMCLC) on visual performance. Methods: This randomized crossover study conducted at the University of Valencia, Spain included 38 presbyopic patients using an artificial pupil contact lens in the nondominant eye and a CBMCLC. After a month of lens wear, the binocular distance visual acuity (BDVA), binocular near visual acuity (BNVA), defocus curve, binocular distance, and near contrast sensitivity and near stereoacuity (NSA) were measured under photopic conditions (85 cd/m2). Moreover, BDVA and binocular distance contrast sensitivity were …

genetic structureseye diseases
researchProduct

Implantable collamer lens and femtosecond laser for myopia: comparison using an adaptive optics visual simulator

2018

Purpose: To compare optical and visual quality of implantable collamer lens (ICL) implantation and femtosecond laser in situ keratomileusis (F-LASIK) for myopia. Methods: The CRX1 adaptive optics visual simulator (Imagine Eyes, Orsay, France) was used to simulate the wavefront aberration pattern after the two surgical procedures for -3-diopter (D) and -6-D myopia. Visual acuity at different contrasts and contrast sensitivities at 10, 20, and 25 cycles/degree (cpd) were measured for 3-mm and 5-mm pupils. The modulation transfer function (MTF) and point spread function (PSF) were calculated for 5-mm pupils. Results: F-LASIK MTF was worse than ICL MTF, which was close to diffraction-limited MT…

researchProduct