0000000000907301
AUTHOR
L. Barber
High-Statistics Sub-Barrier Coulomb Excitation of $^{106,108,110}$Sn
International audience; A Coulomb excitation campaign on $^{106,108,110}$Sn at 4.4–4.5 MeV/u was launched at the HIE-ISOLDE facility at CERN. Larger excitation cross sections and γ-ray statistics were achieved compared to previous experiments at ∼2.8 MeV/u. More precise $(B(E2;0_{1}^{ + } \to 2_{1}^{ + }))$ values, lifetimes of states via the Doppler shift attenuation method, and new $(B(E2;0_{1}^{ + } \to 2_{x}^{ + })), (B(E2;2_{1}^{ + } \to 4_{1}^{ + }))$ and $(Q(2_{1}^{ + }))$ values from the new Miniball data will be obtained and applied to test modern nuclear structure theories.
A time-of-flight correction procedure for fast-timing data of recoils with varying implantation positions at a spectrometer focal plane
Abstract Fast-timing measurements at the focal plane of a separator can suffer from poor timing resolution. This is due to the variations in time-of-flight (ToF) for photons travelling to a given detector, which arise from the changes in the implantation positions of the recoil nuclei emitting the γ rays of interest. In order to minimise these effects on timing measurements, a procedure is presented that improves fast-timing data by performing ToF corrections on an event-by-event basis. This method was used to correct data collected with an array of eight LaBr 3 detectors, which detected γ rays from spatially distributed 138Gd recoil-implants at the focal plane of the Recoil-Ion-Transport-U…
A charge plunger device to measure the lifetimes of excited nuclear states where transitions are dominated by internal conversion
Abstract A charge plunger device has been commissioned based on the DPUNS plunger (Taylor et al., 2013) using the in-flight mass separator MARA at the University of Jyvaskyla. The 152 Sm (32 S ,4 n )180 Pt reaction was used to populate excited states in 180 Pt . A lifetime measurement of the 2 1 + state was performed by applying the charge plunger technique, which relies on the detection of the charge state-distribution of recoils rather than the detection of the emitted γ rays. This state was a good candidate to test the charge plunger technique as it has a known lifetime and depopulates through a converted transition that competes strongly with γ -ray emission. The lifetime of the 2 1 + s…
Lifetime measurements of excited states in ¹⁶³W and the implications for the anomalous B(E2) ratios in transitional nuclei
This letter reports lifetime measurements of excited states in the odd-N nucleus $^{163}$W using the recoil-distance Doppler shift method to probe the core polarising effect of the i13/2 neutron orbital on the underlying soft triaxial even-even core. The ratio B(E2:21/2+→17/2+)/B(E2:17/2+→13/2+) is consistent with the predictions of the collective rotational model. The deduced B(E2) values provide insights into the validity of collective model predictions for heavy transitional nuclei and a geometric origin for the anomalous B(E2) ratios observed in nearby even-even nuclei is proposed.
Lifetime measurements of lowest states in the π g7/2 ⊗ νh11/2 rotational band in 112I
A differential-plunger device was used to measure the lifetimes of the lowest states in the πg7/2 ⊗ νh11/2 rotational band in doubly odd 112I with the 58Ni(58Ni, 3pn) reaction. A differential decay curve method was performed using the fully shifted and degraded γ -ray intensity measurements as a function of target-to-degrader distance. The lifetimes of the lowest three states in the πg7/2 ⊗ νh11/2 band in 112I were measured to be 124(30), 130(25), and 6.5(5) ps, respectively. As the lifetimes of successive excited states in a rotational band are expected to decrease with increasing excitation energy, these measurements suggest that the order of the transitions in the established band in 112…
Lifetime measurements of yrast states in ¹⁷⁸ Pt using the charge plunger method with a recoil separator
Abstract Lifetime measurements in \(^{178}\)Pt with excited states de-exciting through \(\gamma\)-ray transitions and internal electron conversions have been performed. Ionic charges were selected by the in-flight mass separator MARA and measured at the focal plane in coincidence with the \(4^{+}_{1}→2^{+}_{1}\) 257 keV γ-ray transition detected using the JUROGAM 3 spectrometer. The resulting charge-state distributions were analysed using the differential decay curve method (DDCM) framework to obtain a lifetime value of 430(20) ps for the \(2^{+}_{1}\) state. This work builds on a method that combines the charge plunger technique with the DDCM analysis. As an alternative analysis, ions were…
Lifetime measurements of lowest states in the πg7/2⊗νh11/2 rotational band in I112
Identification of excited states in 107,52Te55
Excited states in the extremely neutron-deficient nucleus 107Te have been identified from two separate experiments using the recoil-decay tagging technique. Two connected structures were observed on the basis of γγ-coincidence relations and tentatively assigned as built on the mixed-parentage νg7/2d5/2 and νh11/2 intruder configurations. The observed structures were compared with large-scale shell-model calculations and total Routhian surface calculations. Collective behavior was discovered to persist in the νh11/2 band of 107Te which highlights the shape-polarizing effect of a single valence neutron occupying the h11/2 intruder orbit as the N=50 shell closure is approached. peerReviewed
A charge plunger device to measure the lifetimes of excited nuclear states where transitions are dominated by internal conversion
A charge plunger device has been commissioned based on the DPUNS plunger (Taylor et al., 2013) using the in-flight mass separator MARA at the University of Jyväskylä. The 152Sm(32S,4n)180Pt reaction was used to populate excited states in 180Pt. A lifetime measurement of the 21+ state was performed by applying the charge plunger technique, which relies on the detection of the charge state-distribution of recoils rather than the detection of the emitted γ rays. This state was a good candidate to test the charge plunger technique as it has a known lifetime and depopulates through a converted transition that competes strongly with γ-ray emission. The lifetime of the 21+ state was measured to be…
Lifetime measurements of excited states in $^{163}$W and the implications for the anomalous B(E2) ratios in transitional nuclei
Grahn, Tuomas/0000-0002-6255-2279; Herzan, Andrej/0000-0002-6736-7638; Cullen, Dave/0000-0002-0041-1606; Barber, Liam/0000-0002-7409-9352; Keatings, James Michael/0000-0003-4271-8021; SAYGI, BAHADIR/0000-0001-5406-506X; Greenlees, Paul/0000-0002-5986-5274; Spagnoletti, Pietro/0000-0002-7674-989X; Parr, Edward/0000-0001-6204-4461; Bondili, S Nara Singh/0000-0002-4096-2429
TPEN: A Triple-foil differential Plunger for lifetime measurements of excited states in Exotic Nuclei
Abstract A Triple-foil differential Plunger for Exotic Nuclei (TPEN) has been developed to measure the lifetimes of excited states in nuclei with small production cross-sections. TPEN utilises one target foil and two degrader foils to make differential lifetime measurements: directly determining the decay function and its derivative at a single plunger distance setting. The direct measurement of the decay function and its derivative removes the requirement to measure γ -ray intensities at several target-to-degrader distances, thereby reducing the beam-time required relative to a conventional plunger with a single-degrader foil. This paper describes the commissioning of TPEN in the lifetime …