0000000001012444

AUTHOR

Yong Liu

Prototype tests for a highly granular scintillator-based hadronic calorimeter

Within the CALICE collaboration, several concepts for the hadronic calorimeter of a future lepton collider detector are studied. After having demonstrated the capabilities of the measurement methods in "physics prototypes", the focus now lies on improving their implementation in "technological prototypes", that are scalable to the full linear collider detector. The Analogue Hadronic Calorimeter (AHCAL) concept is a sampling calorimeter of tungsten or steel absorber plates and plastic scintillator tiles read out by silicon photomultipliers (SiPMs) as active components. The front-end electronics is fully integrated into the active layers of the calorimeter and is designed for minimal power co…

research product

Social media overload, exhaustion, and use discontinuance : Examining the effects of information overload, system feature overload, and social overload

While users’ discontinuance of use has posed a challenge for social media in recent years, there is a paucity of knowledge on the relationships between different dimensions of overload and how overload adversely affects users’ social media discontinuance behaviors. To address this knowledge gap, this study employed the stressor–strain–outcome (SSO) framework to explain social media discontinuance behaviors from an overload perspective. It also conceptualized social media overload as a multidimensional construct consisting of system feature overload, information overload, and social overload. The proposed research model was empirically validated via 412 valid questionnaire responses collecte…

research product

Safety and efficacy outcomes after intranasal administration of neural stem cells in cerebral palsy : a randomized phase 1/2 controlled trial

Abstract Background Neural stem cells (NSCs) are believed to have the most therapeutic potential for neurological disorders because they can differentiate into various neurons and glial cells. This research evaluated the safety and efficacy of intranasal administration of NSCs in children with cerebral palsy (CP). The functional brain network (FBN) analysis based on electroencephalogram (EEG) and voxel-based morphometry (VBM) analysis based on T1-weighted images were performed to evaluate functional and structural changes in the brain. Methods A total of 25 CP patients aged 3–12 years were randomly assigned to the treatment group (n = 15), which received an intranasal infusion of NSCs loade…

research product

Precise Measurement of the e+e−→π+π−J/ψ Cross Section at Center-of-Mass Energies from 3.77 to 4.60 GeV

The cross section for the process e(+)e(-)-> pi(+) pi(-) J/psi is measured precisely at center-of-mass energies from 3.77 to 4.60 GeV using 9 fb(-1) of data collected with the BESIII detector operating at the BEPCII storage ring. Two resonant structures are observed in a fit to the cross section. The first resonance has a mass of (222.0 +/- 3.1 +/- 1.4) MeV/ c(2) and a width of (44.1 +/- 4.3 +/- 2.0)MeV, while the second one has a mass of (4320.0 +/- 10.4 +/- 7.0)MeV/c(2) and a width of (101.4(- 19.7)(+25.3) +/- 10.2) MeV, where the first errors are statistical and second ones are systematic. The first resonance agrees with the Y(4260) resonance reported by previous experiments. The precisi…

research product

Comparison of Silicon Photomultiplier Characteristics using Automated Test Setups

Silicon Photomultipliers (SiPM) are photo-sensors consisting of an array of hundreds to thousands pixels with a typical pitch of 10-100 μm. They exhibit an excellent photon counting and time resolution. Therefore applications of SiPMs are emerging in many fields. In order to characterize SiPMs, the PRISMA Detector Lab at Mainz has established three automated test setups. Setup-A is dedicated to measure the gain, the dark count rate and the optical crosstalk probability. The temperature dependencies are characterized by operating the setup in a climate chamber. Setup-B is an optical system to measure the photon detection efficiency. Setup-C addresses the most challenging aspect of comparing …

research product

The ER-Membrane Transport System Is Critical for Intercellular Trafficking of the NSm Movement Protein and Tomato Spotted Wilt Tospovirus.

Plant viruses move through plasmodesmata to infect new cells. The plant endoplasmic reticulum (ER) is interconnected among cells via the ER desmotubule in the plasmodesma across the cell wall, forming a continuous ER network throughout the entire plant. This ER continuity is unique to plants and has been postulated to serve as a platform for the intercellular trafficking of macromolecules. In the present study, the contribution of the plant ER membrane transport system to the intercellular trafficking of the NSm movement protein and Tomato spotted wilt tospovirus (TSWV) is investigated. We showed that TSWV NSm is physically associated with the ER membrane in Nicotiana benthamiana plants. An…

research product

Estimates, trends, and drivers of the global burden of type 2 diabetes attributable to PM2·5 air pollution, 1990–2019: an analysis of data from the Global Burden of Disease Study 2019

Background: Experimental and epidemiological studies indicate an association between exposure to particulate matter (PM) air pollution and increased risk of type 2 diabetes. In view of the high and increasing prevalence of diabetes, we aimed to quantify the burden of type 2 diabetes attributable to PM2·5 originating from ambient and household air pollution.Methods: We systematically compiled all relevant cohort and case-control studies assessing the effect of exposure to household and ambient fine particulate matter (PM2·5) air pollution on type 2 diabetes incidence and mortality. We derived an exposure–response curve from the extracted relative risk estimates using the MR-BRT (meta-regress…

research product

Highly granular calorimeters: technologies and results

The CALICE collaboration is developing highly granular calorimeters for experiments at a future lepton collider primarily to establish technologies for particle flow event reconstruction. These technologies also find applications elsewhere, such as detector upgrades for the LHC. Meanwhile, the large data sets collected in an extensive series of beam tests have enabled detailed studies of the properties of hadronic showers in calorimeter systems, resulting in improved simulation models and development of sophisticated reconstruction techniques. In this proceeding, highlights are included from studies of the structure of hadronic showers and results on reconstruction techniques for imaging ca…

research product

Search for a light exotic particle inJ/ψradiative decays

Using a data sample containing 1.06x10^8 psi' events collected with the BESIII detector at the BEPCII electron-positron collider, we search for a light exotic particle X in the process psi' -> pi^+ pi^- J/psi, J/psi -> gamma X, X -> mu^+ mu^-. This light particle X could be a Higgs-like boson A^0, a spin-1 U boson, or a pseudoscalar sgoldstino particle. In this analysis, we find no evidence for any mu^+mu^- mass peak between the mass threshold and 3.0 GeV/c^2. We set 90%-confidence-level upper limits on the product-branching fractions for J/psi -> gamma A^0, A^0 -> mu^+ mu^- which range from 4x10^{-7} to 2.1x10^{-5}, depending on the mass of A^0, for M(A^0)<3.0 GeV/c^2. On…

research product

A Design of Scintillator Tiles Read Out by Surface-Mounted SiPMs for a Future Hadron Calorimeter

Precision calorimetry using highly granular sampling calorimeters is being developed based on the particle flow concept within the CALICE collaboration. One design option of a hadron calorimeter is based on silicon photomultipliers (SiPMs) to detect photons generated in plastic scintillator tiles. Driven by the need of automated mass assembly of around ten million channels stringently required by the high granularity, we developed a design of scintillator tiles directly coupled with surface-mounted SiPMs. A cavity is created in the center of the bottom surface of each tile to provide enough room for the whole SiPM package and to improve collection of the light produced by incident particles…

research product

Precise Measurement of the e+e− → π+π−J/ψ Cross Section at Center-of-Mass Energies from 3.77 to 4.60 GeV

The cross section for the process e(+)e(-)-> pi(+) pi(-) J/psi is measured precisely at center-of-mass energies from 3.77 to 4.60 GeV using 9 fb(-1) of data collected with the BESIII detector operating at the BEPCII storage ring. Two resonant structures are observed in a fit to the cross section. The first resonance has a mass of (222.0 +/- 3.1 +/- 1.4) MeV/ c(2) and a width of (44.1 +/- 4.3 +/- 2.0)MeV, while the second one has a mass of (4320.0 +/- 10.4 +/- 7.0)MeV/c(2) and a width of (101.4(- 19.7)(+25.3) +/- 10.2) MeV, where the first errors are statistical and second ones are systematic. The first resonance agrees with the Y(4260) resonance reported by previous experiments. The precisi…

research product