0000000001211968

AUTHOR

Valeria Puleo

showing 29 related works from this author

Multicriteria performance analysis of an integrated urban wastewater system for energy management

2017

AbstractThe optimization and management of an integrated urban wastewater system is a complex problem involving many processes and variables. The possible control options are defined by several management strategies that may differently impact the economic, operational or environmental performance of the system. The present paper aims to contribute to the environmental and energy sustainability of urban wastewater systems by means of a multicriteria performance analysis. The paper begins with a complete analysis of the system performance in several fields of interest (energy, environment, quality of service, operation, economy and financial resources), and it highlights the management stren…

EngineeringAtmospheric ScienceEnergy management0208 environmental biotechnologyControl (management)Urban water cycle02 engineering and technology010501 environmental sciences01 natural sciencesEnergy sustainabilityIntegrated Urban Wastewater System0105 earth and related environmental sciencesCivil and Structural EngineeringWater Science and Technologybusiness.industryQuality of serviceSettore ICAR/02 - Costruzioni Idrauliche E Marittime E IdrologiaEnvironmental engineeringDecision Support SystemEnvironmental economicsGeotechnical Engineering and Engineering Geology020801 environmental engineeringPerformance IndicatorWastewater systemsEnergy ManagementbusinessStrengths and weaknesses
researchProduct

A mathematical model to evaluate apparent losses due to meter under-registration in intermittent water distribution networks

2013

Apparent losses consist of water volume drawn from the network, consumed by users but not paid for. Those due to water meter under-registration were evaluated by means of a mathematical model able to analyse the complexity of intermittent supply systems with private tanks. This supply scheme is very common in the Mediterranean area where unexpected water shortage often happens and intermittent water supply is a common practice. In order to analyse such complex systems, a demand model, reproducing the effect of private tanks, and an apparent losses module were developed and coupled with an hydraulic network model based on the Global Gradient Algorithm (GGA). In distribution networks pressure…

EngineeringDistribution networksbusiness.industrySettore ICAR/02 - Costruzioni Idrauliche E Marittime E IdrologiaComplex systemWater supplyWater scarcityWater meter substitution planPressure managementMetreApparent losseWater volumebusinessWater meter under-registrationSimulationPrivate tankWater Science and TechnologyNetwork modelMarine engineeringWater Supply
researchProduct

The Effect of Damage Functions on Urban Flood Damage Appraisal

2014

Flooding damage appraisal can been obtained by interpolating real damage data caused by historical flooding events or accounting the effects of a flood in terms of the depreciation of assets. Most often, the expected damage is evaluated by means of damage functions describing the relationship occurring between the damage and hydraulic characteristics of flood. The present paper aims to evaluate the uncertainty linked to the choice of the depth-damage function adopted in the flood damage analysis. Several possible depth-damage function formulations were selected in literature and applied to historical flooding events monitored in the "Centro Storico" catchment in Palermo (Italy). (C) 2013 Th…

damage curveFlood mythForensic engineeringDamage analysisEnvironmental scienceGeneral MedicineFlood damageuncertainty analysidepth-damage functionuncertainty analysisUncertainty analysisEngineering(all)Flooding (computer networking)Procedia Engineering
researchProduct

Evaluation of the Water Scarcity Energy Cost for Users

2013

Abstract: In systems experiencing water scarcity and consequent intermittent supply, users often adopt private tanks that collect water during service periods and supply users when the service is not available. The tank may be fed by gravity or by private pumping stations depending on the network pressure level. Once water resources are collected, the tank can supply users by gravity if it is located on the rooftop or by additional pumping if underground. Private tanks thus increase the energy cost of the water supply service for users by introducing several small pumping structures inside the network. The present paper aims to evaluate this users’ energy cost for different private tank con…

EngineeringControl and OptimizationResource (biology)Distribution networksEnergy Engineering and Power TechnologyWater supplyDistribution (economics)ComputerApplications_COMPUTERSINOTHERSYSTEMSlcsh:TechnologyGeneralLiterature_MISCELLANEOUSWater scarcityjel:Q40jel:Qjel:Q43jel:Q42jel:Q41jel:Q48intermittent supplyComputerSystemsOrganization_SPECIAL-PURPOSEANDAPPLICATION-BASEDSYSTEMSjel:Q47Electrical and Electronic Engineeringdistribution networkEngineering (miscellaneous)jel:Q49Service (business)lcsh:TRenewable Energy Sustainability and the Environmentbusiness.industryjel:Q0water scarcityEnvironmental economicsjel:Q4energy costWater resourcesdistribution networksdistribution networks; energy cost; intermittent supply; water scarcityEnergy costbusinessWater resource managementEnergy (miscellaneous)Energies
researchProduct

Energy Recovery in Water Distribution Networks. Implementation of Pumps as Turbine in a Dynamic Numerical Model

2014

In complex networks characterized by the presence of private tanks, water managers usually apply intermittent distribution, thus reducing the water volumes supplied to the users, or use Pressure Reduction Valves (PRV) for controlling pressure in the network. The application of Pump As Turbines (PATs) appears as an alternative and sustainable solution to either control network pressure as well as to produce energy. In the present paper, the hydrodynamic model, already presented by De Marchis et al. (2011) was further developed introducing the dynamic analysis of PATs. The model was applied to a district of Palermo network (Italy) characterized by intermittent distribution and by inequities a…

EngineeringEnergy recoveryDistribution networksPetroleum engineeringbusiness.industryEnvironmental engineeringWater supplyGeneral MedicineComplex networkPump as Turbine (PAT)TurbineTerm (time)method of characteristicenergy savingwater distribution networkControl networkintermittent distributionbusinessEnergy (signal processing)Engineering(all)energy saving.Procedia Engineering
researchProduct

Multivariate Statistical Analysis for Water Demand Modeling

2014

The actual level of water demand is the driving force behind the hydraulic dynamics in water distribution systems. Consequently, it is crucial to estimate it as accurately as possible in order to result in reliable simulation models. In this paper, a copula-based multivariate analysis has been proposed and used for demand prediction for given return period. The analysis is applied to water consumption data collected in the water distribution network of Palermo (Italy). The approach showed to produce consisted demand patterns and to be a powerful tool to be coupled with water distribution network models for design or analysis problems. (C) 2014 Published by Elsevier Ltd.

Return periodMultivariate analysisMultivariate analysiDemand patternsSimulation modelingGeneral Medicinewater demand modeling.Copula (probability theory)Water demandVine copulaMultivariate analysisvine copulaStatisticsEconometricsEnvironmental scienceMultivariate statisticalEngineering(all)water demand modelingProcedia Engineering
researchProduct

Definition of Water Meter Substitution Plans based on a Composite Indicator

2014

This paper presents a water meter substitution plan based on a composite "Replacement indicator" which was defined and compared with common substitution strategies based on meter age and on run-to-fail approaches. The methodology was applied to one of the 17 sub-networks in which the Palermo city water distribution network (Italy) is divided. The analysis was carried out considering a substitution budget limitation and the results showed that the use of "Replacement indicator" outperform the classical substitution strategies based on meter age because it takes into account some other variables that may affect meter precision and wearing. (C) 2013 The Authors. Published by Elsevier Ltd.

replacement strategyEngineeringDistribution networksbusiness.industrySubstitution (logic)General MedicinePlan (drawing)Composite indicatorCivil engineeringwater metersForensic engineeringApparent losseswater distribution systemsMetreApparent lossebusinesswater distribution systemEngineering(all)metering errorProcedia Engineering
researchProduct

Multi Sources Water Supply System Optimal Control: A Case Study

2014

The optimal operation of a multi quality network was analysed applying Linear Programming methods. The peculiar service condition of the industrial city of Gela (Italy) was investigated. The network is supplied both from waters derived from a desalination plant and other natural sources. The method aimed to minimise energy cost and find the optimal operation control, while satisfying demand and quality constraints, specifically with regard to water temperature. The method proved to be effective in the selection of the optimal management strategy after the definition of a specific water quality target. (C) 2014 Published by Elsevier Ltd.

OptimizationEngineeringMathematical optimizationmulti source supplyLinear programmingbusiness.industrymedia_common.quotation_subjectEnvironmental engineeringWater supplymulti source supply.General MedicineOptimal controlDesalinationwater qualityOptimal managementdesalinationQuality (business)Water qualitybusinessSelection (genetic algorithm)Engineering(all)media_common
researchProduct

Contaminant Intrusion through Leaks in Water Distribution System: Experimental Analysis

2015

Abstract This paper presents the results of experimental tests on the intrusion of contaminant through pipe cracks in water distribution network resulting from low/negative pressures. The tests were carried out on a looped distribution network at the University of Enna and were performed first producing a pressure transient that causes negative pressures then reproducing intermittent supply. A soluble contaminant was added to the water volume in the network through a pipe crack. Sampling of water volume was carried out in two nodes of the network and the contaminant concentrations were measured. It was showed that: the contaminant was drawn in and transported, in the first set of tests; the…

Steady stateDistribution networkspollutant intrusionSampling (statistics)transient analysiGeneral MedicineTransient analysisDistribution systemHealth risksIntrusionHealth riskEnvironmental scienceintermittent distributionGeotechnical engineeringWater volumeTransient (oscillation)transient analysiswater distribution systemEngineering(all)Procedia Engineering
researchProduct

Experimental Evidence of Leaks in Elastic Pipes

2016

Several studies have been carried out in recent decades to establish a relationship between total head and leaks. In literature, the leakage governing equations have been analysed in light of pipe materials, water head, leak dimension or shape. Most of these contributions questioned the classical Torricelli equation, demonstrating through experimental evidence that the classical orifice law can give unsatisfactory results. Nevertheless, starting from the Torricelli equation, other exponential or linear governing equations have been proposed as mathematical models able to reproduce the leakages in water distribution systems (WDSs). To investigate the validity of the proposed governing equati…

Laboratory testLeakEngineering0208 environmental biotechnologyPopulationRigidity (psychology)02 engineering and technology010501 environmental sciences01 natural sciencesHydraulic headExperimentGeotechnical engineeringeducationElastic pipe0105 earth and related environmental sciencesWater Science and TechnologyCivil and Structural Engineeringeducation.field_of_studyHydrogeologyMathematical modelbusiness.industryMechanicsWater distribution network020801 environmental engineeringExponential functionHead-leakage formulaLeakbusinessBody orifice
researchProduct

A Decision Support Tool for Water and Energy Savingin the Integrated Water System

2015

Abstract In the last decades, a growing attention on energy saving associated with water resources usage and leakages reduction has been recorded at both national and international level. Scientific research has focused on implementation of several methodologies aimed at the understanding of energy transformation processes occurring in the integrated water system. The main concern is then identifying energy impacts associated to each macro-area of integrated water system, such as collection, treatment and distribution, and analysing the potential interactions between them. Unfortunately, only overall energy consumptions are usually available at national level. The main objective of the pape…

Water supply systemdecision support tool.Service (systems architecture)Decision support systemEngineeringDecision support toolwater lossesbusiness.industrySettore ICAR/02 - Costruzioni Idrauliche E Marittime E IdrologiaEnergy balanceWater supplyGeneral MedicineEnvironmental economicsWater resourcesEngineering (all)Water losseEnergy savingSustainabilityEnergy transformationMacroWater resource managementbusinessEngineering(all)Procedia Engineering
researchProduct

An Environmental Analysis of the Effect of Energy Saving, Production and Recovery Measures on Water Supply Systems under Scarcity Conditions

2015

Water is one of the primary resources provided for maintaining quality of life and social status in urban areas. As potable water is considered to be a primary need, water service has usually been managed without examining the economic and environmental sustainability of supply processes. Currently, due to increases in energy costs and the growth of environment preservation policies, reducing water leakage, energy consumption and greenhouse gas (GHG) production have become primary objectives in reducing the environmental footprint of water service. The present paper suggests the implementation of some performance indicators that show the interdependence of water loss, energy consumption and…

Control and OptimizationNatural resource economicsleakageEnergy Engineering and Power TechnologyWater supplylcsh:Technologyjel:Q40Water conservationjel:Qjel:Q43jel:Q42jel:Q41jel:Q48jel:Q47Electrical and Electronic EngineeringEngineering (miscellaneous)jel:Q49Energy recoveryRenewable Energy Sustainability and the Environmentbusiness.industrylcsh:Twater supplyEnvironmental resource managementjel:Q0Energy consumptionperformance indicatorsjel:Q4Energy conservationGreenhouse gasSustainabilityEnvironmental sciencewater supply; energy; leakage; GHG; performance indicatorsGHGbusinessEnergy (miscellaneous)Efficient energy useenergyEnergies
researchProduct

Urban drainage and sustainable cities: how to achieve flood resilient societies?

2012

This paper tries to describe the main developments of urban flood forecasting and modelling. Currently, several new technologies are available for flood monitoring, modelling and mitigation and several paradigms suggest the adoption of greener approaches to urban storm water management. These tools and new approaches can be easily adaptable to new developments where the entire urban drainage system can be suited to follow a more sustainable way to drain storm water. The challenge for the future is instead aimed to apply this new philosophy to existing urban areas where the application of new tools and technologies requires high costs and such approaches have to be prepared by constructing a…

geographygeography.geographical_feature_categoryFlood mythEmerging technologiesurban flooding storm water management urban drainage modelling flood mitigationFlood forecastingStormwaterCivil engineeringStorm water managementEnvironmental scienceFlood mitigationDrainageEnvironmental planningDrainage system (agriculture)
researchProduct

A composite indicator for water meter replacement in an urban distribution network

2012

In water supply management, volumetric water meter are typically used to measure users' consumption. With water meters, utilities can collect useful data for billing, assess the water balance of the system, and identify failures in the network, water theft and anomalous user behaviour. Despite their importance, these instruments are characterised by intrinsic errors that cause so-called apparent losses. The complexity of the physical phenomena associated with metering errors in aging water meters does not allow meter replacement to be guided by single parameters, such as the meter age or the total volume passed through the meter. This paper presents a meter replacement strategy based on a c…

EngineeringMeasure (data warehouse)business.industryComputingMethodologies_MISCELLANEOUSGeography Planning and DevelopmentWater supplycomposite indicatorReliability engineeringWater balanceapparent lossewater meterHardware_GENERALRobustness (computer science)MetreMetering modebusinessuncertainty analysismetering errorReliability (statistics)Uncertainty analysisSimulationWater Science and TechnologyUrban Water Journal
researchProduct

Multi-stage Linear Programming Optimization for Pump Scheduling

2014

This study presents a methodology based on Linear Programming for determining the optimal pump schedule on a 24-hour basis, considering as decision variables the continuous pump flow rates which are subsequently transformed into a discrete schedule. The methodology was applied on a case study derived from the benchmark Anytown network. To evaluate the LP reliability, a comparison was made with solutions generated by a Hybrid Discrete Dynamically Dimensioned Search (HD-DDS) algorithm. The cost associated with the result derived from the LP initial solution was shown to be lower than that obtained with repeated HD-DDS runs with differing random seeds. (C) 2013 The Authors. Published by Elsevi…

Pump schedulingOptimizationEngineeringMathematical optimizationLinear programmingbusiness.industryGeneral MedicineHD-DDSScheduling (computing)Pump flowMulti stageDecision variablesLinear ProgrammingbusinessEngineering(all)Procedia Engineering
researchProduct

Energy, water and environmental balance of a complex water supply system

2015

The present paper describes the analysis of water and energy balance in a complex urban water supply system. The analysis was carried out employing Life Cycle Analysis (LCA) methodologies. The LCA approach was integrated with the analysis of the system energy and water balance. For a real size water supply system, based on the results of the individual LCAs, the current baseline was constructed highlighting the water, energy and environmental (in terms of CO2eq emissions in the atmosphere) costs of supplied water. Then, three different mitigation measures have been evaluated: the first is based on energy production by installation of photovoltaic systems; the second is based on energy recov…

Water resourcesEnergy recoveryWater conservationWater balancelife cycle assessment scenario analysis potable water supply sanitation urban water systemsbusiness.industryPhotovoltaic systemEnergy balanceEnvironmental engineeringWater supplyEnvironmental sciencebusinessLife-cycle assessmentWIT Transactions on Ecology and the Environment
researchProduct

Experimental Investigation for Local Tank Inflow Model

2014

In the present paper the effect of private roof tanks and of the float valve characteristics on apparent losses due to water meter errors was investigated via an experimental study. The tests were carried out at the Environmental Hydraulic Laboratory of the University of Enna (Italy), on a high-density polyethylene (HDPE 100 PN16) looped distribution network. The experimental results showed that network pressure plays an important role in the characterisation of the floating ball valve emitter law, but the tank operating condition is the most relevant aspect to be considered mainly for water meter error evaluation. (C) 2014 The Authors. Published by Elsevier Ltd.

Laboratory testEngineeringFloat (project management)business.industryLaboratory testsGeneral MedicineInflowfloat valvePolyethylenelocal tank modelling.Civil engineeringchemistry.chemical_compoundchemistryBall valvelocal tank modellingMetreHigh-density polyethylenebusinessRoofEngineering(all)Common emitterMarine engineeringProcedia Engineering
researchProduct

Pumps as turbines (PATs) in water distribution networks affected by intermittent service

2013

A hydraulic model was developed in order to evaluate the potential energy recovery from the use of centrifugal pumps as turbines (PATs) in a water distribution network characterized by the presence of private tanks. The model integrates the Global Gradient Algorithm (GGA), with a pressure-driven model that permits a more realistic representation of the influence on the network behaviour of the private tanks filling and emptying. The model was applied to a real case study: a District Metered Area in Palermo (Italy). Three different scenarios were analysed and compared with a baseline scenario (Scenario 0 – no PAT installed) to identify the system configuration with added PATs that permits th…

Atmospheric ScienceService (systems architecture)geographyEngineeringgeography.geographical_feature_categorybusiness.industryNode (networking)Monte Carlo methodGeotechnical Engineering and Engineering GeologyCentrifugal pumpInletpressure-driven demandenergy productionwater distribution networkshydraulic modellingNetwork performancepump as turbineBaseline (configuration management)businessDownstream (networking)SimulationCivil and Structural EngineeringWater Science and TechnologyMarine engineeringJournal of Hydroinformatics
researchProduct

Effects of network pressure on water meter under-registration: an experimental analysis

2018

Abstract. In water supply systems, a considerable amount of apparent loss is caused by meter under-registration. Water meters are subject to intrinsic systemic error depending on the actual flow rates passing through them. Furthermore, the moving parts of the meter are subject to wear and tear that progressively reduce meter accuracy. The increase in systemic error is especially evident at low flow rates because of growing friction in the rotating mechanism, which requires a higher flow to start the meter (starting flow). The aim of this paper is to experimentally investigate metering error in an attempt to find a direct link between meter age, network pressure and apparent losses caused by…

Test benchEngineeringThermal mass flow meterMass flow meterPositive displacement meterbusiness.industryUltrasonic flow meterFlow (psychology)MetreMetering modebusinessSimulationMarine engineering
researchProduct

The apparent losses due to metering errors: a proactive approach to predict losses and schedule maintenance

2014

The effects of water meter age and private tanks on the apparent losses due to metering errors were evaluated by experimental and theoretical analyses. A monitoring campaign on a small district metered area (DMA) was carried out to determine the causes of apparent losses and implement a numerical model. Metering errors are affected by the flow rate passing through the meter, which is dependent on the network pressure and water level of the private tank. A node model that reproduces the effect of private tanks was coupled with EPANET and was applied to the DMA. The proposed modelling approach was used to identify where apparent losses are higher and to schedule maintenance. The model predict…

ScheduleEngineeringPetroleum engineeringReducerbusiness.industryGeography Planning and DevelopmentFlow (psychology)water meter under-registrationwater meter substitution planapparent losseprivate water tankMetreNode (circuits)Metering modebusinessunmeasured flow reducerSimulationWater Science and TechnologyUrban Water Journal
researchProduct

Impact of rainfall data resolution in time and space on the urban flooding evaluation.

2013

Climate change and modification of the urban environment increase the frequency and the negative effects of flooding, increasing the interest of researchers and practitioners in this topic. Usually, flood frequency analysis in urban areas is indirectly carried out by adopting advanced hydraulic models to simulate long historical rainfall series or design storms. However, their results are affected by a level of uncertainty which has been extensively investigated in recent years. A major source of uncertainty inherent to hydraulic model results is linked to the imperfect knowledge of the rainfall input data both in time and space. Several studies show that hydrological modelling in urban are…

Environmental EngineeringTime FactorsFlood mythSpacetimeMeteorologyGeographyHydrological modellingClimate ChangeRainFlooding (psychology)UncertaintyClimate changeStormModels TheoreticalFloodsItalyAdded valueCitiesGLUEWater Science and TechnologyEnvironmental MonitoringWater science and technology : a journal of the International Association on Water Pollution Research
researchProduct

Multivariate statistical analysis for water demand modelling: implementation, performance analysis, and comparison with the PRP model

2015

Water demand is the driving force behind hydraulic dynamics in water distribution systems. Consequently, it is crucial to accurately estimate the actual water use to develop reliable simulation models. In this study, copula-based multivariate analysis was proposed and used for demand prediction for a given return period. The analysis was applied to water consumption data collected in the water distribution network of Palermo (Italy). The approach produced consistent demand patterns and could be a powerful tool when coupled with water distribution network models for design or analysis problems. The results were compared with those obtained using a classical water demand model, the Poisson re…

Return periodAtmospheric ScienceEngineeringMultivariate statisticsMultivariate analysisDemand patterns0208 environmental biotechnology02 engineering and technologyPoisson distributionCopula (probability theory)Vine copulasymbols.namesakeStatisticsEconometricsmultivariate analysiwater demand modellingCivil and Structural EngineeringWater Science and Technologybusiness.industryGeotechnical Engineering and Engineering Geology020801 environmental engineeringvine copulasymbolsPoisson rectangular pulse modelbusinessWater useJournal of Hydroinformatics
researchProduct

Water and Energy Saving in Urban Water Systems: The ALADIN Project

2016

The ALADIN project was aimed at contributing to environmental and energy sustainability of the urban water system by means of a decision support tool able to allow an evaluation of the energy impact related to each different macro-sectors of urban water cycle highlighting the main energy flows and to assess the system energy balance and identify the possible energy-efficient solutions. Moreover the tool suggests the most efficient actions in reducing water losses. In the present paper the main features of the developed tool are presented. (C) 2016 The Authors. Published by Elsevier Ltd. This is an open access article under the CC BY-NC-ND license.

urban water systemsEngineeringDecision support systemwater savingperformance indicatordecision support system020209 energyEnergy balanceUrban water cycle02 engineering and technologyurban water systemenergy saving0202 electrical engineering electronic engineering information engineeringEnergy sustainabilityEngineering(all)business.industryEnergy impactEnvironmental engineeringGeneral Medicineperformance indicatorsEnvironmental economicsmonitoringPerformance indicatorUrban waterbusinessEnergy (signal processing)Procedia Engineering
researchProduct

Impact of diffusion and dispersion of contaminants in water distribution networks modelling and monitoring

2019

Abstract In recent years, there has been a need to seek adequate preventive measures to deal with contamination in water distribution networks that may be related to the accidental contamination and the deliberate injection of toxic agents. Therefore, it is very important to create a sensor system that detects contamination events in real time, maintains the reliability and efficiency of measurements, and limits the cost of the instrumentation. To this aim, two problems have to be faced: practical difficulties connected to the experimental verification of the optimal sensor configuration efficiency on real operating systems and challenges related to the reliability of the network modelling …

Distribution networksChemical physics0208 environmental biotechnologyDispersion (optics)Environmental science02 engineering and technology010501 environmental sciencesDiffusion (business)Contamination01 natural sciences020801 environmental engineering0105 earth and related environmental sciencesWater Science and TechnologyWater Supply
researchProduct

Water losses dynamic modelling in water distribution networks

2015

In the last decades, one of the main concerns of the water system managers have been the minimisation of water losses, that frequently reach values of 30% or even 70% of the volume supplying the water distribution network. The economic and social costs associated with water losses in modern water supply systems are rapidly rising to unacceptably high levels. Furthermore, the problem of the water losses assumes more and more importance mainly when periods of water scarcity occur or when not sufficient water supply takes part in areas with fast growth. In the present analysis, a dynamic model was used for estimating real and apparent losses of a real case study. A specific nodal demand model …

EngineeringWater losseDistribution networksbusiness.industryWater network modelingEnvironmental engineeringWater supplyDynamic modellingbusinessdistribution networkWater scarcityAIP Conference Proceedings
researchProduct

CONFRONTO TRA UN MODELLO DINAMICO ED UNO STAZIONARIO NELLA VALUTAZIONE DELLE PERDITE REALI ED APPARENTI DI UNA RETE DI DISTRIBUZIONE

2012

Nel presente articolo è stato applicato un modello dinamico di simulazione idraulica delle reti di distribuzione per la valutazione delle perdite idriche reali ed apparenti. Sono stati sviluppati uno modello di domanda al nodo che simula i serbatoi privati ed un modulo per la stima delle perdite apparenti. Le perdite reali sono state modellate attraverso una relazione generale che esprime la portata effluente dalla perdita come una funzione della pressione. I risultati ottenuti sono stati confrontati con le stime modellistiche basate su di un approccio stazionario.

analisi reti idriche di distribuzione valutazione perdite idriche modelli idraulici di simulazione
researchProduct

PUMP AS TURBINE (PAT) IN INTERMITTENT DISTRIBUTION NETWORKS

2012

A hydraulic model was performed in order to evaluate potential energy recovery resulting by the use of centrifugal pump as turbines (PAT) in the water distribution network characterized by the presence of private tanks. The model integrates the Enhanced Global Gradient Algorithm (EGGA) (Todini [1], Giustolisi et al. [2]), with a pressure driven model (Criminisi et al. [3]) that entails a more realistic representation of the influence of the private tanks filling and emptying process in the network behaviour. The model was applied to real case study: a district metered area in Palermo (Italy). Namely three different scenarios were analyzed and compared with the actual scenario (Scenario 0 - …

energy production hydraulic modelling pressure-driven demand pump as turbine water distribution networks
researchProduct

Real-time optimal control of water distribution systems - Models and techniques, including intermittent supply conditions.

2014

water distribution networkSettore ICAR/02 - Costruzioni Idrauliche E Marittime E Idrologiahydraulic modellingoptimal control systemoptimization
researchProduct

A BASIC DECISION SUPPORT SYSTEM FOR IMPROVING SERVICE LEVEL IN INTERMITTENT WATER DISTRIBUTION SYSTEMS

2012

INTERMITTENT WATER DISTRIBUTION SYSTEMSDECISION SUPPORT SYSTEMSERVICE LEVELS
researchProduct