Performance study of the fast timing Cherenkov detector based on a microchannel plate PMT

Prototype of the fast timing Cherenkov detector, applicable in high-energy collider experiments, has been developed basing on the modified Planacon XP85012 MCP-PMT and fused silica radiators. We present the reasons and description of the MCP-PMT modification, timing and amplitude characteristics of the prototype including the summary of the detector's response on particle hits at oblique angles and MCP-PMT performance at high illumination rates.

research product

Anode current saturation of ALD-coated Planacon MCP-PMTs

We have measured and compared the characteristics of ALD-coated Planacon MCP-PMTs (XP85112/A1-Q-L) with their non-ALD counterparts (XP85012/A1-Q). While the later show excellent performance, the ALD-coated sensors have surprisingly low current saturation levels (~two orders of magnitude lower than expected) and extremely high gain recovery time (more than 7 orders of magnitude higher than expected). We suspect that these problems might be caused by the unexpected side-effects of the ALD process. To make a definite conclusion, more samples need to be tested, preferably from different production runs. If our observation were confirmed, it would mean a serious technological setback for ALD-coa…

research product

Study of the Planacon XP85012 photomultiplier characteristics for its use in a Cherenkov detector

Main properties of the multi-anode microchannel plate photomultiplier to be used in a Cherenkov detector are discussed. The laboratory test results obtained using irradiation of the MCP-PMT photocathode by picosecond optical laser pulses with different intensities (from single photon regime to the PMT saturation conditions) are presented. peerReviewed

research product

Fast timing and trigger Cherenkov detector for collider experiments

Analysis of fast timing and trigger Cherenkov detector's design for its use in collider experiments is presented. Several specific requirements are taken into account - necessity of the radiator's placement as close to the beam pipe as possible along with the requirement of gapless (solid) radiator's design. Characteristics of the Cherenkov detector's laboratory prototype obtained using a pion beam at the CERN Proton Synchrotron are also presented, showing the possibility of obtaining sufficiently high geometrical efficiency along with good enough time resolution (50 ps sigma).

research product

Performance of the cost-effective Planacon ® MCP-PMTs in strong magnetic fields

We present the behavior of the cost-effective Planacon MCP-PMTs with pore diameter in the presence of axial magnetic fields up to 0.5 T. Having a batch of 62 devices of the same type, two MCP-PMTs were selected and their gain variation measured in different magnetic fields. These two otherwise identical devices satisfied the selection criteria by requiring the lowest (1.15 kV) and one of the highest (1.4 kV) bias voltage values to achieve a given gain. Both MCP-PMTs have a nearly identical tolerance of the strong magnetic field despite the significant difference in the bias voltage. This clarifies the mechanism of the B-field influence on the MCP-PMT gain, emphasizing the importance of the …

research product