0000000001323550
AUTHOR
Daniela Lopes-ferreira
Short-Term Changes in Light Distortion in Orthokeratology Subjects
Purpose. Quantifying adaptation to light distortion of subjects undergoing orthokeratology (OK) for myopia during the first month of treatment. Methods. Twenty-nine healthy volunteers (age: 22.34 ± 8.08 years) with mean spherical equivalent refractive error −2.10 ± 0.93D were evaluated at baseline and days 1, 7, 15, and 30 of OK treatment. Light distortion was determined using an experimental prototype. Corneal aberrations were derived from corneal topography for different pupil sizes. Contrast sensitivity function (CSF) was analyzed for frequencies of 1.50, 2.12, 3.00, 4.24, 6.00, 8.49, 12.00, 16.97, and 24.00 cpd under photopic conditions. Results. Average monocular values of all light di…
Tear film stability over a myopia control contact lens compared to a monofocal design
Background: To compare the short-term effect of two contact lenses on pre-lens tear film stability and comfort: dual-focus contact lens (MiSight) and a monofocal contact lens (Proclear 1-day).Methods: This randomised, double-masked, crossover study was performed in twenty-eight healthy, myopic volunteers aged between 18 and 32 years (23.5 +/- 4.1 years). Only one randomly chosen eye was assessed. Distance vision and refraction were evaluated at baseline. Each contact lens type (monofocal and dual-focus) was randomly fitted, always in both eyes. A visual analogue scale between 0 and 10 was used to assess general comfort, physical comfort, and visual comfort. Tear Film Surface Quality (TFSQ) …
Corrigendum to “Short-term changes in light distortion in orthokeratology subjects"
Artigo completo publicado na revista "BioMed Research International, (2015), 1-7" e disponível no RepositóriUM em: http://hdl.handle.net/1822/33375
Reliability of manual segmentation of cornea, contact lens and tear film using a high-resolution OCT
In this study, we aimed to evaluate the intra/inter-session and intra/inter-observer variability of manual segmentation of thickness of the pre-lens tear film, contact lens (CL), post-lens tear film, epithelium, bowman’s layer, stroma and the whole cornea and CLs with a flat and a steep fit, using a commercial high-resolution spectral domain optical coherence tomographer (OCT). Two different observers obtained three repeated measures in two separate sessions. A high correlation was found between the values obtained by the two different observers, except for the thinner layers, epithelium, and Bowman’s layer. Inter-observer analysis showed a high consistency in the measurements obtained by b…
Visual acuity changes in presbyopic patients fitted with 3 multifocal contact lenses
Proclear EP vs placebo: visual outcomes and symptoms of asthenopia in nonpresbyopes and early presbyopes
Purpose: Over the past 20 years, many studies have reported the success of multifocal contact lenses (MFCLs) compared to monovision (MV), with only partial success being reported for MFCLs. Chronologically it appears there has been a gradual improvement in the performance of MFCLs. This study investigated whether this change in success is reflected in clinical practice. Method: Lens fit data collected from 2005 to 2009 by the International Contact Lens Prescribing Survey Consortium was reviewed for patients over 45 years old. A similar survey conducted from 1988 to 1989 was also reviewed and compared. Twelve published (Pubmed.gov) reports of clinical trials involving MFCLs and MV were revie…