6533b7d0fe1ef96bd125a581
RESEARCH PRODUCT
Development of a new multi-analyte assay for the simultaneous detection of opioids in serum and other body fluids using liquid chromatography-tandem mass spectrometry.
J. RöhrichK. EckartR. Laufenberg-feldmannM. FernerD. BreitmeierR. Urbansubject
ChromatographyChemistryClinical BiochemistryCodeineReproducibility of ResultsCell BiologyGeneral MedicineEthylmorphineBiochemistryDihydrocodeineAnalytical ChemistryTriple quadrupole mass spectrometerBody FluidsAnalgesics Opioidchemistry.chemical_compoundLiquid chromatography–mass spectrometryLimit of DetectionTandem Mass SpectrometryIntensive caremedicineMorphineHumansNorbuprenorphinemedicine.drugChromatography Liquiddescription
Abstract A liquid chromatography–tandem mass spectrometry method using electrospray ionization in positive ionization mode was developed for the simultaneous detection of multiple opioid-type drugs in plasma. The presented assay allows the quantitative determination of alfentanil, buprenorphine, codeine, desomorphine, dextromethorphan, dextrorphan, dihydrocodeine, dihydromorphine, ethylmorphine, fentanyl, hydrocodone, hydromorphone, methadone, morphine, naloxone, naltrexone, oxycodone, oxymorphone, pentazocine, pethidine, pholcodine, piritramide, remifentanil, sufentanil, and tramadol as well as the metabolites 6-monoacetylmorphine, bisnortilidine, morphine-3-glucuronide, morphine-6-glucuronide, naltrexol, norbuprenorphine, norfentanyl, norpethidine, nortilidine, and O -desmethyltramadol. Serum and blood samples were purified by solid-phase extraction. The analytes were separated on a phenyl–hexyl (100 mm) column by formic acid/acetonitrile gradient elution using an UPLC 1290 Infinity coupled with a 6490 Triple Quadrupole mass spectrometer. The limits of detection ranged from 0.02 to 0.6 ng/mL and the lower limits of quantification ranged from 0.1 to 2.0 ng/mL. The calibration curves were linear between Calibration Levels 1–6 for all 35 substances. Recovery rates ranged between 51 and 88% for all compounds except alfentanil, bisnortilidine, pethidine, and morphine-3-glucuronide. The matrix effect ranged from 86% for ethylmorphine to 105% for desomorphine. Using the validation procedure proposed by the German Society of Toxicological and Forensic Chemistry, acceptable precision and accuracy data for almost all analytes were obtained. The method was successfully applied to 206 authentic serum samples provided by the palliative and intensive care units of the University Medical Center and the police authorities. Furthermore, a suspected fatal intoxication is demonstrated by an analysis of the sufentanil in post mortem body fluids and tissues.
year | journal | country | edition | language |
---|---|---|---|---|
2015-09-01 | Journal of chromatography. B, Analytical technologies in the biomedical and life sciences |