Compatibility of epirubicin-loaded DC bead™ with different non-ionic contrast media
Irene KrämerIman Sarakbisubject
Non ionicChemistry PharmaceuticalDrug CompoundingContrast Media01 natural sciences03 medical and health scienceschemistry.chemical_compound0302 clinical medicineDrug StabilityMedicinePharmacology (medical)Chromatography High Pressure LiquidEpirubicinPolypropyleneDrug CarriersEpirubicin InjectionChromatographyDrug eluting beadsbusiness.industrySyringes010401 analytical chemistryMicrospheres0104 chemical sciencesOncologychemistry030220 oncology & carcinogenesisCompatibility (mechanics)PowdersbusinessEpirubicinmedicine.drugdescription
Purpose The aim of this study was to determine the compatibility of epirubicin-loaded DC bead™ with different non-ionic contrast media over a period of seven days when stored light protected under refrigerated conditions. Methods DC bead™ (2 ml) (Biocompatibles UK Ltd) of the bead size 70–150 µm ( = DC bead M1) or bead size 100–300 µm were loaded with 75 mg epirubicin powder formulation (Farmorubicin® dissolved in 3 ml water for injection to a concentration of 25 mg/ml) or 76 mg epirubicin injection solution (Epimedac® 2 mg/ml) within 2 h or 6 h, respectively. After removal of the excess solution, the epirubicin-loaded beads were mixed in polypropylene syringes with an equal volume (∼1.5 ml) of contrast media, i.e. Accupaque™ 300 (Nycomed Inc.), Imeron® 300 (Bracco S.p.A), Ultravist® 300 (Bayer Pharma AG), Visipaque™ 320 (GE Healthcare) and agitated in a controlled manner to get a homogenous suspension. Syringes with loaded beads in contrast media were stored protected from light under refrigeration (2–8℃). Compatibility was determined by measuring epirubicin concentrations in the suspensions in triplicate on day 0, 1, and 7. A reversed phase high-performance liquid chromatography assay with ultraviolet detection was utilized to analyze the concentration and purity of epirubicin. Results Mixing of epirubicin-loaded beads with different non-ionic contrast media released 0.1–0.5% of epirubicin over a period of 24 h, irrespectively, of the DC bead™ size or type of contrast media. No further elution or degradation was observed after seven days when the admixtures were stored protected from light under refrigeration. Conclusion Compatibility of epirubicin-loaded DC bead™ with an equal volume of different contrast media in polypropylene syringes is given over a period of seven days. Due to a maximum elution of 0.1–0.5% of epirubicin from loaded DC bead™, admixtures with contrast media can be prepared in advance in centralized cytotoxic preparation units. Microbiological aspects have to be considered when determining the expiration date of the product.
year | journal | country | edition | language |
---|---|---|---|---|
2016-07-09 | Journal of Oncology Pharmacy Practice |