Search results for "Syringes"
showing 10 items of 10 documents
Curasan PRP kit vs. PCCS PRP system
2002
An important reason to improve methods of isolating platelet-rich plasma (PRP) is the potential use of autologous thrombocyte growth factors. In addition to discontinuous cell separation, two methods for extracting PRP that can be performed directly by the surgeon are now available. This study compared the suitability of these two methods for the preparation of PRP. Whole blood was drawn from 47 healthy donors (18 men, 29 women) aged 20-59 years (mean 29.9, SD 7.7). For each donor, PRP was separated by the PCCS method (PCCS Kit, 3i Implant Innovations, Palm Beach Gardens, FL, USA) and by the Curasan method (analogous to the PRP kit, Curasan, Kleinostheim, Germany). Thrombocyte counts differ…
Use of needles and syringes in Miami and Valencia: observations of high and low availability.
2000
Two studies engaged in gathering data on injecting drug users (IDUs) employed supplementary resources to enhance their ethnographic components and compare patterns of use of needles/syringes (n/s) in two geographically similar but culturally distinct cities. Despite its policy of making n/s highly available at fair prices, Valencia, Spain, has markedly higher rates of HIV seroprevalence among its IDUs than does Miami, Florida, where possession of n/s is illegal. Ethnographically based models that track IDUs through choices of injection venues help to explain this difference. Inability of IDUs in Valencia to use their own domiciles as venues for injection contrasts sharply with problems of M…
Under Pressure: Comparison of Aspiration Techniques for Endovascular Mechanical Thrombectomy.
2018
BACKGROUND AND PURPOSE: Blood flow should be interrupted during mechanical thrombectomy to prevent embolization of clot fragments. The purpose of our study was to provide a handy overview of the most common aspiration devices and to quantify their flow characteristics. MATERIALS AND METHODS: We assessed volumetric flow rates generated by a 60-mL VacLok vacuum pressure syringe, a Pump MAX aspiration pump, and a Dominant Flex suction pump connected to the following: 1) an 8F long sheath, 2) an 8F balloon-guide catheter, 3) an ACE 64 distal aspiration catheter, and 4) an AXS Catalyst 6 Distal Access Catheter. We used a water/glycerol solution, which was kept at a constant temperature of 20°C (…
Loading, release and stability of epirubicin-loaded drug-eluting beads.
2015
Purpose The aim of this study was to determine the loading efficiency, physico-chemical stability and release of epirubicin-loaded DC Bead™ (Biocompatibles UK Ltd, a BTG International group company) (bead size 70–150 µm (=DC Bead M1™) and 100–300 µm) after loading with epirubicin solution (2 mg/ml) or reconstituted powder formulation (25 mg/ml) and controlled storage. Methods DC Bead™ were loaded with 76 mg epirubicin solution (Epimedac™, Medac GmbH) or 75 mg epirubicin powder formulation (Farmorubicin™, Pharmacia Pfizer GmbH) per 2 ml of beads. Drug loading efficiency and stability were determined by measuring the epirubicin concentration in the excess solution after predetermined interval…
In syringe hybrid monoliths modified with gold nanoparticles for selective extraction of glutathione in biological fluids prior to its determination …
2020
Abstract In this work, a simple device for extraction glutathione (GSH) in biological fluids using a hybrid monolithic material within a polypropylene syringe is developed. For this purpose, glycidyl methacrylate-based monolith was firstly prepared within this housing material, and the polymer was modified with different ligands (ammonia, cysteamine and cystamine). The resulting materials (containing amine or thiol groups, respectively) were then functionalized with gold nanoparticles (AuNPs). The hybrid material that gave the largest AuNPs coverage was selected as solid-phase (SPE) sorbent and several variables affecting the extraction recovery of this compound were investigated. Under opt…
Compatibility of epirubicin-loaded DC bead™ with different non-ionic contrast media
2016
Purpose The aim of this study was to determine the compatibility of epirubicin-loaded DC bead™ with different non-ionic contrast media over a period of seven days when stored light protected under refrigerated conditions. Methods DC bead™ (2 ml) (Biocompatibles UK Ltd) of the bead size 70–150 µm ( = DC bead M1) or bead size 100–300 µm were loaded with 75 mg epirubicin powder formulation (Farmorubicin® dissolved in 3 ml water for injection to a concentration of 25 mg/ml) or 76 mg epirubicin injection solution (Epimedac® 2 mg/ml) within 2 h or 6 h, respectively. After removal of the excess solution, the epirubicin-loaded beads were mixed in polypropylene syringes with an equal volume (∼1.5 ml…
Clinical efficacy of a computerised device (STA™) and a pressure syringe (VarioJect INTRA™) for intraligamentary anaesthesia.
2014
Introduction To evaluate the impact of experience whilst using different devices for intraligamentary anaesthesia, dental students tested clinical anaesthetic efficacy of a mechanical (PDL-S) and a computer-controlled (CCLAD) application system in restorative patients. Material and methods In a prospective study, 41 Patients in need of restorative treatment in lower posterior mandible were randomised into three groups (PDL-S: teeth n = 22; CCLAD: teeth n = 20; inferior alveolar nerve block (IANB): teeth n = 20). Dental last year students conducted anaesthesia and dental treatment. Primary objectives were differences in pain during treatment [numeric rating scale (NRS)] as well as in anaesth…
Lung fixation for the preservation of air spaces.
2004
The procedures for the fixation of entire lungs of small rodents are presented together with various techniques used to verify the structural integrity of the lung tissue. To achieve this, the lungs were dissected out from rats and mice killed by ether overdose. The specimens were rinsed with isotonic saline and fixation solution under low vacuum conditions. After fixation, they were dried using alcohol and stored in a noncollapsed state (i.e., state of inhalation). Light and scanning electron microscopy as well as magnetic resonance imaging using hyperpolarized 3He were employed to verify the intact state on interalveolar septa and walls of smaller bronchi as well as accessibility of the a…
Microbial contamination of anesthetic syringes in relation to different handling habits.
2015
This single-center study prospectively assessed the microbial contamination of anesthetic syringes handled perioperatively under different conditions. We documented high rates of bacterial contamination, with strong but statistically nonsignificant differences between handling groups. Our results identify skin contact as the main source of contamination, and thus we emphasize the impact of proper hand hygiene.
Media-fill simulation tests in manual and robotic aseptic preparation of injection solutions in syringes
2014
Objective The purpose of this study was to evaluate the contamination rate of media-fill products either prepared automated with a robotic system (APOTECAchemo™) or prepared manually at cytotoxic workbenches in the same cleanroom environment and by experienced operators. Media fills were completed by microbiological environmental control in the critical zones and used to validate the cleaning and disinfection procedures of the robotic system. Methods The aseptic preparation of patient individual ready-to-use injection solutions was simulated by using double concentrated tryptic soy broth as growth medium, water for injection and plastic syringes as primary packaging materials. Media fills w…