A statistical design of experiments for optimizing the MALDI-TOF-MS sample preparation of polymers. An application in the assessment of the thermo-mechanical degradation mechanisms of poly (ethylene terephthalate).

Amparo Ribes-greusJosé David BadiaEmma StrömbergSigbritt Karlsson

subject

Solucions polimèriquesEthylenePolymersAnalytical chemistryDegradation kineticsBiochemistryThermo-mechanical degradationSample preparation procedureAnalytical ChemistryMatrix (chemical analysis)chemistry.chemical_compoundDegradationGlycolsMatrix assisted laser desorption ionization time of flight mass spectrometryPolyethylene terephthalateMechanismsCationizationSample preparationRecyclingMechanical recyclingSpectroscopyPriority journalchemistry.chemical_classificationDithranolSignal to noise ratioPolyethylene terephthalateHydrolysisMultiple processingPolymerPoly (ethylene terephthalate)Potential reactionsInjection cyclesMAQUINAS Y MOTORES TERMICOSInductively coupled plasmaSimulationEthersMatrix-assisted laser desorption/ionization time-of-flightQuality parametersDesign of ExperimentsGlycol unitsSample preparationArticleEthyleneEnvironmental ChemistryPolyethylene terephthalatesMALDI TOF MSSignal noise ratioMass spectrometryMatrixTermoplàsticsSignal to noiseTransesterificationDegradation mechanismMatrix-assisted laser desorption/ionizationStatistical design of experimentsTransesterificationchemistryChemical engineeringOligomersDesorptionEthylene glycolControlled studyProcess optimization

description

[EN] The sample preparation procedure for MALDI-TOF MS of polymers is addressed in this study by the application of a statistical Design of Experiments (DoE). Industrial poly (ethylene terephthalate) (PET) was chosen as model polymer. Different experimental settings (levels) for matrixes, analyte/matrix proportions and concentrations of cationization agent were considered. The quality parameters used for the analysis were signal-to-noise ratio and resolution. A closer inspection of the statistical results provided the study not only with the best combination of factors for the MALDI sample preparation, but also with a better understanding of the influence of the different factors, individually or in combination, to the signal. The application of DoE for the improvement of the MALDI measure of PET stated that the best combination of factors and levels was the following: matrix (dithranol), proportion analyte/matrix/cationization agent (1/15/1, V/V/V), and concentration of cationization agent (2gL -1). In a second part, multiple processing by means of successive injection cycles was used to simulate the thermo-mechanical degradation effects on the oligomeric distribution of PET under mechanical recycling. The application of MALDI-TOF-MS showed that thermo-mechanical degradation primarily affected initially predominant cyclic species. Several degradation mechanisms were proposed, remarking intramolecular transesterification and hydrolysis. The ether links of the glycol unit in PET were shown to act as potential reaction sites, driving the main reactions of degradation. © 2011 Elsevier B.V.

10.1016/j.aca.2011.02.063https://pubmed.ncbi.nlm.nih.gov/21501716