6533b7d6fe1ef96bd1266ec7
RESEARCH PRODUCT
Operation of the MAMI accelerator with a Wien filter based spin rotation system
Kurt AulenbacherV. Tioukinesubject
PhysicsNuclear and High Energy PhysicsWien filterRotationNuclear physicsRotation systemBeam trajectoryPhysics::Accelerator PhysicsFocal lengthLaser beam qualityNuclear ExperimentSpin (physics)InstrumentationMicrotrondescription
A compact spin rotation system based on a Wien filter has been installed at the Mainz microtron accelerator (MAMI). Under operation with varying spin rotation angles a significant change of focal length together with a shift of the central beam trajectory is expected. We demonstrate that these effects can be kept under control. As a consequence operation with spin rotation angles between 0° and ±90° has been achieved without compromising the beam quality and operational stability of MAMI.
year | journal | country | edition | language |
---|---|---|---|---|
2006-12-01 | Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment |