0000000000059834
AUTHOR
Kurt Aulenbacher
Test and Commissioning of the HELIAC Power Coupler
The superconducting continuous wave (cw) heavy ion HElmholtz LInear ACcelerator (HELIAC) is intended to be built at GSI in Darmstadt. With its high average beam current and repetition rate, the HELIAC is designed to fulfill the requirements of the super heavy element (SHE) research user program and the material sciences community at GSI. The accelerating cavities are of the superconducting Crossbar H-mode (CH) type, developed by GUF. Within the Advanced Demonstrator project, the first cryomodule, consisting of four cavities is scheduled for commissioning with beam in 2023. The former RF power couplers introduced a high heat input into the cryostat. Therefore, the coupler is redesigned at HI…
First attempt of the measurement of the beam polarization at an accelerator with the optical electron polarimeter POLO
The conventional methods for measuring the polarization of electron beams are either time consuming, invasive or accurate only to a few percent. We developped a method to measure electron beam polarization by observing the light emitted by argon atoms following their excitation by the impact of polarized electrons. The degree of circular polarization of the emitted fluorescence is directly related to the electron polarization. We tested the polarimeter on a test GaAs source available at the MAMI electron accelerator in Mainz, Germany. The polarimeter determines the polarization of a 50 keV electron beam decelerated to a few eV and interacting with an effusive argon gas jet. The resulting de…
Reconstruction of the Longitudinal Phase Space for the Superconducting CW HELIAC
Proceedings of the 19th International Conference on RF Superconductivity The 19th International Conference on RF Superconductivity, Dresden, Germany, 30 Jun 2019 - 5 Jul 2019; Geneva : JACoW Publishing, CERN 1175-1179 (2019). doi:10.18429/JACOW-SRF2019-THP103
A superconducting CW-LINAC for heavy ion acceleration at GSI
The European physical journal / Web of Conferences 138, 01026 (2017). doi:10.1051/epjconf/201713801026
The polarized electron-nucleon collider project ENC at GSI/FAIR
The ENC project attempts to realize an electron-nucleon collider at the upcoming Facility for Antiproton and Ion Research FAIR at GSI Darmstadt by utilizing the antiproton high-energy storage ring HESR for polarized proton and deuteron beams. The addition of a 3.3 GeV storage ring for polarized electrons will enable electron-nucleon collisions up to a center-of-mass energy of - s - 14 GeV. In such a configuration peak luminosities in the range of L = 10(32) to 10(33)cm(-')(2)s(-')(1) are feasible . Beam-beam effects in a space-charge dominated regimes in conjunction with high-energy electron cooling represents one of the main challenges for this project. In this paper beam- and spin dynamic…
Operation of the MAMI accelerator with a Wien filter based spin rotation system
A compact spin rotation system based on a Wien filter has been installed at the Mainz microtron accelerator (MAMI). Under operation with varying spin rotation angles a significant change of focal length together with a shift of the central beam trajectory is expected. We demonstrate that these effects can be kept under control. As a consequence operation with spin rotation angles between 0° and ±90° has been achieved without compromising the beam quality and operational stability of MAMI.
Cleanroom Installations for SRF Cavities at the Helmholtz-Institut Mainz
The 10th International Particle Accelerator Conference, IPAC2019, Melbourne, Australia, 19 May 2019 - 24 May 2019; JACoW Publishing, Geneva, Switzerland 2830-2833 (2019). doi:10.18429/JACOW-IPAC2019-WEPRB015
Coherent Smith-Purcell radiation for minimally invasive bunch length measurement at the subpicosecond time scale
Physical review accelerators and beams 24(4), 042803 (2021). doi:10.1103/PhysRevAccelBeams.24.042803
A Mott polarimeter operating at MeV electron beam energies.
We have developed a Mott electron polarimeter for the Mainzer microtron (MAMI) accelerator in Mainz, Germany. At beam energies ranging between 1.0 and 3.5 MeV two double focusing magnet spectrometers collect elastically backscattered electrons from gold targets. In spite of the small spectrometer acceptance, a sufficient statistical efficiency is achieved to provide very fast measurements if beam currents typical for experiments at MAMI are being used. High reproducibility is achieved, demonstrating that the results of asymmetry measurements are independent of the primary beam current in a range from 0.004 to 45 μA at a level of <1% relative variation. Compared to low energy polarimeters of…
Spin polarized electron transport and partial localization of photoelectrons in highly doped photocathodes
The results of experimental and theoretical studies of spin polarized electron transport in semiconductor SL used for photoemitter application are presented. The experimental study is based on the time resolved measurements of electron emission from the cathode after its photoexcitation by fs laser pulse. The response and spin relaxation times have been determined by means of measured time dependent intensity and polarization of electron emission. We also performed theoretical calculations of photocathode pulse response and compared the obtained results with experimental data. Our analysis testifies the presence of partial electron localization in SL. Electron capture by localized states le…
Advanced Beam Dynamics Design for the Superconducting Heavy Ion Accelerator HELIAC
The 10th International Particle Accelerator Conference, IPAC2019, Melbourne, Australia, 19 May 2019 - 24 May 2019; JACoW Publishing, Geneva, Switzerland 928-931 (2019). doi:10.18429/JACOW-IPAC2019-MOPTS034
Sidebands in Optically Detected Magnetic Resonance Signals of Nitrogen Vacancy Centers in Diamond
We study features in the optically detected magnetic resonance (ODMR) signals associated with negatively charged nitrogen-vacancy (NV) centers coupled to other paramagnetic impurities in diamond. Our results are important for understanding ODMR line shapes and for optimization of devices based on NV centers. We determine the origins of several side features to the unperturbed NV magnetic resonance by studying their magnetic field and microwave power dependences. Side resonances separated by around 130 MHz are due to hyperfine coupling between NV centers and nearest-neighbor C-13 nuclear spins. Side resonances separated by approximately {40, 260, 300} MHz are found to originate from simultan…
First heavy ion beam tests with a superconducting multigap CH cavity
Physical review accelerators and beams 21(2), 020102 (2018). doi:10.1103/PhysRevAccelBeams.21.020102
Fluorescence and spin properties of defects in single digit nanodiamonds
International audience; This article reports stable photoluminescence and high-contrast optically detected electron spin resonance (ODESR) from single nitrogen-vacancy (NV) defect centers created within ultrasmall, disperse nanodiamonds of radius less than 4 nm. Unexpectedly, the efficiency for the production of NV fluorescent defects by electron irradiation is found to be independent of the size of the nanocrystals. Fluorescence lifetime imaging shows lifetimes with a mean value of around 17 ns, only slightly longer than the bulk value of the defects. After proper surface cleaning, the dephasing times of the electron spin resonance in the nanocrystals approach values of some microseconds, …
Measurement of the parity violating asymmetry in the quasielastic electron-deuteron scattering and improved determination of the magnetic strange form factor and the isovector anapole radiative correction
A new measurement of the parity-violating asymmetry in the electron-deuteron quasielastic scattering for backward angles at $⟨{Q}^{2}⟩=0.224\text{ }\text{ }{(\mathrm{GeV}/c)}^{2}$, obtained in the A4 experiment at the Mainz Microtron accelerator (MAMI) facility, is presented. The measured asymmetry is ${A}_{PV}^{d}=(\ensuremath{-}20.11\ifmmode\pm\else\textpm\fi{}0.8{7}_{\mathrm{stat}}\ifmmode\pm\else\textpm\fi{}\phantom{\rule{0ex}{0ex}}1.0{3}_{\mathrm{sys}})\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}6}$. A combination of these data with the proton measurements of the parity-violating asymmetry in the A4 experiment yields a value for the effective isovector axial-vector form facto…
Workshop on Sources of Polarized Leptons and High Brightness Electron Beams
This volume contains the proceedings of the International Workshop on Sources of Polarized Leptons and High Brightness Electron Beams (PESP2010). The workshop was hosted by the University of Bonn from 21–24 September 2010. PESP2010 has been conducted as satellite workshop preceding the International SPIN Physics Symposium (SPIN2010). In view of the expanding and challenging field of the production of high brightness lepton beams, the selection of workshop topics was extended to cover the demands of modern accelerator developments and applications. As novel light sources such as FELs and ERLs place new requirements on the properties of unpolarized beams in terms of brightness and intensity, …
Collimation of Target Induced Halo Following MAGIX at MESA
The Mainz Energy-recovering Superconducting Accelerator (MESA) will be an electron accelerator allowing operation in energy-recovery linac (ERL) mode. It provides the opportunity to operate scattering experiments at energies of ~100 MeV with thin gas-targets. The MESA Internal Gas Target Experiment (MAGIX) aims to operate windowless jet targets and different gases up to Xenon to search for possible dark photon interactions, to precisely measure the magnetic proton radius and astrophysical S-factors. Investigations on the impact of the target on beam dynamics and beam losses are required for machine safety and to examine limits to ERL operation. The goal of this work is to understand target …
Beam Dynamics Simulations for the New Superconducting CW Heavy Ion LINAC at GSI
LINAC18 : 29th Linear Accelerator Conference : September 16-21, 2018, Friendship Hotel, Beijing, China / Pei, Guoxi , Geneva : JACoW Publishing, CERN, Jan 2019,; Geneva : JACoW Publishing, Geneva, Switzerland 525--527 (2018). doi:10.18429/JACOW-LINAC2018-TUPO084
Determination of the neutron electric form factor in the D(e,e′n)p reaction and the influence of nuclear binding
The electric form factor of the neutron GE,n has been determined at the Mainz Microtron MAMI at the low momentum transfer Q2= 0.15 (GeV/c)2 in a measurement of the recoil polarisation ratio Px/Pz in the quasifree reaction D(e,e′n)p. At this Q2 the influence of the nuclear binding is strong. A purely kinematical model is used to get some insight into the effect of the initial Fermi momentum distribution of the neutron. The influence of the final state interaction is determined quantitatively by a model of Arenhovel et al.. After the corresponding corrections a value of GE,n(0.15 (GeV/c)2) = 0.0481±0.0065stat±0.0053syst is obtained.
Clinical microbeam radiation therapy with a compact source: specifications of the line-focus X-ray tube
Highlights • Line-focus X-ray tubes are suitable for clinical microbeam radiation therapy (MRT). • A modular high-voltage supply safely enables high electron beam powers. • An electron accelerator was designed to generate an eccentric focal spot. • We simulated a peak-to-valley dose ratio above 20 for single-field MRT. • Microbeam arc therapy spares healthy brain tissue compared to single-field MRT.
The 1.5GeV harmonic double-sided microtron at Mainz University
Abstract At the Institut fur Kernphysik of Mainz University a harmonic double-sided microtron (HDSM) has been built to extend the experimental capabilities for nuclear and particle physics experiments to higher excitation energies. This novel microtron variant accelerates the 0.855 GeV continuous wave (cw) electron beam of the established three-staged race track microtron (RTM) cascade MAMI B up to 1.5 GeV. It consists of two normal conducting linear accelerators (linacs) through which the electrons are guided up to 43 times by a pair of 90°-bending magnets at each end. For beam dynamical reasons the linacs operate at the harmonic frequencies of 4.90 and 2.45 GHz. The extended facility is c…
Reconstruction of the Longitudinal Phase Portrait for the SC CW Heavy Ion HELIAC at GSI
Proceedings of the 10th International Particle Accelerator Conference The 10th International Particle Accelerator Conference, Melbourne, Australia, 19 May 2019 - 24 May 2019; JACoW Publishing, Geneva, Switzerland 898-901 (2019). doi:10.18429/JACOW-IPAC2019-MOPTS024
Determination of the neutron electric form factor from the reaction 3 He(e,e'n) at medium momentum transfer
The electric form factor of the neutron GEn has been determined in double polarized exclusive 3He(e,e'n) scattering in quasi–elastic kinematics by measuring asymmetries A⊥, A∥ of the cross section with respect to helicity reversal of the electron, with the nuclear spin being oriented perpendicular to the momentum transfer q in case of A⊥ and parallel in case of A∥. The experiment was performed at the 855 MeV c. w. microtron MAMI at Mainz. The degree of polarization of the electron beam and of the gaseous 3He target were each about 50%. Scattered electrons and neutrons were detected in coincidence by detector arrays covering large solid angles. Quasi–elastic scattering events were reconstruc…
Precision electron beam polarimetry for next generation nuclear physics experiments
Polarized electron beams have played an important role in scattering experiments at moderate to high beam energies. Historically, these experiments have been primarily targeted at studying hadronic structure — from the quark contribution to the spin structure of protons and neutrons, to nucleon elastic form factors, as well as contributions to these elastic form factors from (strange) sea quarks. Other experiments have aimed to place constraints on new physics beyond the Standard Model. For most experiments, knowledge of the magnitude of the electron beam polarization has not been a limiting systematic uncertainty, with only moderately precise beam polarimetry requirements. However, a new …
Photoemission of spinpolarized electrons from strained GaAsP
Strained layer GaAs.95P.05 photo cathodes are presented, which emit electron beams spinpolarized to a degree of P = 75% typically. Quantum yields around QE = 0.4% are observed routinely. The figure of merit P2 × QE = 2.3 × 10−3 is comparable to that of the best strained layer cathodes reported in literature. The optimum wavelength of irradiating light around 830 nm is in convenient reach of Ti:sapphire lasers or diode lasers respectively. The cathodes are produced using MOCVD-techniques. A GaAs.55P.45-GaAs.85P.15 superlattice structure prevents the migration of dislocations from the substrate and bottom layers to the strained overlayer. The surface is protected by an arsenic layer so that n…
New Measurements of the Beam Normal Spin Asymmetries at Large Backward Angles with Hydrogen and Deuterium Targets
International audience; New measurements of the beam normal single spin asymmetry in the electron elastic and quasielastic scattering on the proton and deuteron, respectively, at large backward angles and at ⟨Q2⟩=0.22 (GeV/c)2 and ⟨Q2⟩=0.35 ( GeV/c)2 are reported. The experimentally observed asymmetries are compared with the theoretical calculation of Pasquini and Vanderhaeghen [Phys. Rev. C 70, 045206 (2004).PRVCAN0556-281310.1103/PhysRevC.70.045206]. The agreement of the measurements with the theoretical calculations shows a dominance of the inelastic intermediate excited states of the nucleon, πN and the Δ resonance. The measurements explore a new, important parameter region of the exc…
Reducing the contribution of the photoemission process to the unwanted beam in photoelectron sources at accelerators
Negative electron affinity (NEA) GaAs photocathodes show different pulse responses depending on the wavelength of photoexcitation. The pulse response at 800 nm shows a long and relatively intense tail, whereas at 400 nm, a tail of similar shape but with an intensity lower by around two orders of magnitude is observed. We explain this behavior with the specific properties of NEA photocathodes and compare it with the response of a positive electron affinity photocathode.
Further RF Measurements on the Superconducting 217 MHz CH Demonstrator Cavity for a CW Linac at GSI
Proceedings of the 10th International Particle Accelerator Conference The 10th International Particle Accelerator Conference, Melbourne, Australia, 19 May 2019 - 24 May 2019; Geneva : JACoW Publishing, CERN 2826-2829 (2019). doi:10.18429/JACOW-IPAC2019-WEPRB014