6533b820fe1ef96bd127a67c

RESEARCH PRODUCT

Application of Thin ZnO ALD Layers in Fiber-Optic Fabry-Pérot Sensing Interferometers

Małgorzata Jędrzejewska-szczerskaDaria MajchrowiczRoman ViterPaweł WierzbaMikhael BechelanyMarzena Hirsch

subject

Fabry-Pérot interferometerOptical fiberMaterials scienceinterferenceZnO layer02 engineering and technologylcsh:Chemical technologyInterference (wave propagation)01 natural sciencesBiochemistryArticleAnalytical Chemistrylaw.inventionAtomic layer depositionOpticslawAstronomical interferometerlcsh:TP1-1185Fiber[PHYS.PHYS.PHYS-INS-DET]Physics [physics]/Physics [physics]/Instrumentation and Detectors [physics.ins-det]Electrical and Electronic EngineeringInstrumentation[PHYS.PHYS.PHYS-OPTICS]Physics [physics]/Physics [physics]/Optics [physics.optics]business.industry010401 analytical chemistry021001 nanoscience & nanotechnologyAtomic and Molecular Physics and Optics0104 chemical sciencesInterferometryAtomic Layer DepositionFabry-Pérot interferometer; Atomic Layer Deposition; ZnO layer; interference0210 nano-technologybusinessRefractive indexFabry–Pérot interferometer

description

International audience; In this paper we investigated the response of a fiber-optic Fabry-Pérot sensing interferometer with thin ZnO layers deposited on the end faces of the optical fibers forming the cavity. Standard telecommunication single-mode optical fiber (SMF-28) segments were used with the thin ZnO layers deposited by Atomic Layer Deposition (ALD). Measurements were performed with the interferometer illuminated by two broadband sources operating at 1300 nm and 1550 nm. Reflected interference signal was acquired by an optical spectrum analyzer while the length of the air cavity was varied. Thickness of the ZnO layers used in the experiments was 50 nm, 100 nm, and 200 nm. Uncoated SMF-28 fiber was also used as a reference. Based on the results of measurements, the thickness of the ZnO layers and the length of the cavity were selected in order to achieve good visibility. Following, the interferometer was used to determine the refractive index of selected liquids.

10.3390/s16030416https://hal.umontpellier.fr/hal-01682247