6533b826fe1ef96bd12851f4
RESEARCH PRODUCT
Technical and economical comparison between different topologies of PV plant under mismatch effect
D. La MannaG. Ricco GalluzzoV. Di DioGiovanni CiprianiRosario Micelisubject
PV plant topologyEngineeringtopologyeconomic evaluationtechnical-economical comparative analysiPV arraypartially shaded photovoltaic plantTransportationTopology (electrical circuits)GeneratorSettore ING-IND/32 - Convertitori Macchine E Azionamenti ElettriciNetwork topologyTVenergy productionpower generation economicComponent (UML)photovoltaic plant topologycostpower lossesElectronic engineeringeries-parallel topologyInverterTotal cross tiedmismatch effecttotal cross tied topologySPbusiness.industryPhotovoltaic systemArrayBiological system modelingTCT topology plantpower generation planningSwitcheReliability engineeringphotovoltaic power systemSP topology plantTCTInverterPv plantbusinessdescription
This paper presents a technical and economical comparative analysis between two topology of photovoltaic plant. In particular the performances of series-parallel (SP) and total cross tied (TCT), topologies are taken into account, referring to a partially shaded photovoltaic plant. Thanks to a simulation model developed, in the paper the mismatch effects due to three different shading conditions, for SP and TCT topology plant, are quantified. Since the TCT solution, even though increase the energy production, raise the complexity of plants as well as their costs, an evaluation of the individual costs of each component of a SP and TCT plant topology, as PV modules, support structure, inverter, protection devices, cables and wiring, ordinary maintenance and so on, is carried out. © 2014 IEEE.
year | journal | country | edition | language |
---|---|---|---|---|
2014-03-01 | 2014 Ninth International Conference on Ecological Vehicles and Renewable Energies (EVER) |