6533b830fe1ef96bd1296767
RESEARCH PRODUCT
Comparative Performance of Linear Multielectrode Probes and Single-Tip Electrodes for Intracortical Microstimulation and Single-Neuron Recording in Macaque Monkey.
Marco LanzilottoMonica MaranesiCarolina Giulia FerroniLuca BoniniAlessandro Livisubject
0301 basic medicineHand regionMaterials scienceCognitive NeuroscienceNeuroscience (miscellaneous)Acute recording; Chronic recording; Electrical stimulation; Macaque monkey; Silicon probes; Neuroscience (miscellaneous); Developmental Neuroscience; Cognitive Neuroscience; Cellular and Molecular NeuroscienceMacaquechronic recording03 medical and health sciencesCellular and Molecular Neuroscience0302 clinical medicineDevelopmental Neurosciencebiology.animalmedicinePremovement neuronal activitysilicon probeselectrical stimulationOriginal Researchbiologytechnology industry and agricultureequipment and suppliesmacaque monkeyMicroelectrode030104 developmental biologyIntracortical microstimulationmedicine.anatomical_structureElectrodeacute recordingNeuron030217 neurology & neurosurgeryBiomedical engineeringMotor cortexNeurosciencedescription
Intracortical microstimulation (ICMS) is one of the most widely employed techniques for providing causal evidence of the relationship between neuronal activity and specific motor, perceptual, or even cognitive functions. In recent years, several new types of linear multielectrode silicon probes have been developed, allowing researchers to sample neuronal activity at different depths along the same cortical site simultaneously and with high spatial precision. Nevertheless, silicon multielectrode probes have been rarely employed for ICMS studies and, more importantly, it is unknown whether and to what extent they can be used for combined recording and stimulation experiments. Here, we addressed these issues during both acute and chronic conditions. First, we compared the behavioral outcomes of ICMS delivered to the hand region of a monkey’s motor cortex with multielectrode silicon probes, commercially available multisite stainless-steel probes and single-tip glass-coated tungsten microelectrodes. The results for all three of the probes were reliable and similar. Furthermore, we tested the impact of long-train ICMS delivered through chronically implanted silicon probes at different time intervals, from 1 to 198 days after ICMS sessions, showing that although the number of recorded neurons decreased over time, in line with previous studies, ICMS did not alter silicon probes’ recording capabilities. These findings indicate that in ICMS experiments, the performance of linear multielectrode silicon probes is comparable to that of both single-tip and multielectrode stainless-steel probes, suggesting that the silicon probes can be successfully used for combined recording and stimulation studies in chronic conditions.
year | journal | country | edition | language |
---|---|---|---|---|
2017-05-05 | Frontiers in systems neuroscience |