6533b85ffe1ef96bd12c2762

RESEARCH PRODUCT

Electromagnetic calorimetry with PbWO/sub 4/ in the energy regime below 1 GeV

R. BeckR. W. NovotnyA. HofstaetterW. DoringV. HejnyH. StroherMikhail KorzhikVolker Metag

subject

PhysicsNuclear and High Energy PhysicsScintillationPhotonSpectrometerPhysics::Instrumentation and DetectorsNiobiumchemistry.chemical_elementCalorimetryCalorimeterNuclear physicsNuclear Energy and EngineeringchemistryElectrical and Electronic EngineeringNuclear ExperimentSpectroscopyPhotonic crystal

description

The study of the performance and application of PbWO/sub 4/ in electromagnetic calorimetry at energies far below 1 GeV has been continued. The significantly improved optical and scintillation properties of 15 cm long Nb/La-doped crystals, optimized for the ECAL/CMS calorimeter, are documented. The lineshape, energy and time response of a 5/spl times/5 matrix are tested with monoenergetic photons up to 790 MeV energy and compared to previous measurements. First attempts have been made to enhance the scintillation yield by suitable dopants (Mo,Tb) for applications at very low photon energies. As a first large scale project at medium energies, the proposed concept for a compact photon spectrometer to be implemented into the ANKE magnetic spectrometer at COSY (KFA Julich) is illustrated.

https://doi.org/10.1109/nssmic.1999.842483