6533b872fe1ef96bd12d4446
RESEARCH PRODUCT
Dorsal root ganglia neurite outgrowth measured as a function of changes in microelectrode array resistance
Erik D. EngebergJordan M. RennaRebecca Kuntz WillitsJessica M. Stukelsubject
EmbryologyDistribution CurvesCell Culture Techniqueslcsh:MedicineElectrode Recording02 engineering and technologyChick Embryolaw.invention0302 clinical medicinelawAnimal CellsGanglia SpinalMedicine and Health SciencesElectric Impedancelcsh:ScienceMembrane ElectrophysiologyCells CulturedNeuronsProstheticsMultidisciplinaryChemistryMultielectrode arraymedicine.anatomical_structureBioassays and Physiological AnalysisElectrodePhysical SciencesEngineering and TechnologyCellular TypesResearch ArticleStatistical DistributionsBiotechnologyDorsumNeuritePhase contrast microscopy0206 medical engineeringNeuronal OutgrowthResearch and Analysis Methods03 medical and health sciencesmedicineNeuritesAnimalsElectrodeslcsh:RElectrophysiological TechniquesEmbryosBiology and Life SciencesCell BiologyNeuronal DendritesChick embryosProbability Theory020601 biomedical engineeringAssistive Technologiesnervous systemReference ElectrodesCellular Neurosciencelcsh:QMedical Devices and EquipmentNeuronElectronicsMicroelectrodes030217 neurology & neurosurgeryMathematicsBiomedical engineeringNeuroscienceDevelopmental Biologydescription
Current research in prosthetic device design aims to mimic natural movements using a feedback system that connects to the patient's own nerves to control the device. The first step in using neurons to control motion is to make and maintain contact between neurons and the feedback sensors. Therefore, the goal of this project was to determine if changes in electrode resistance could be detected when a neuron extended a neurite to contact a sensor. Dorsal root ganglia (DRG) were harvested from chick embryos and cultured on a collagen-coated carbon nanotube microelectrode array for two days. The DRG were seeded along one side of the array so the processes extended across the array, contacting about half of the electrodes. Electrode resistance was measured both prior to culture and after the two day culture period. Phase contrast images of the microelectrode array were taken after two days to visually determine which electrodes were in contact with one or more DRG neurite or tissue. Electrodes in contact with DRG neurites had an average change in resistance of 0.15 MΩ compared with the electrodes without DRG neurites. Using this method, we determined that resistance values can be used as a criterion for identifying electrodes in contact with a DRG neurite. These data are the foundation for future development of an autonomous feedback resistance measurement system to continuously monitor DRG neurite outgrowth at specific spatial locations.
| year | journal | country | edition | language |
|---|---|---|---|---|
| 2017-04-01 | PLoS ONE |