Search results for " Acoustics"
showing 10 items of 183 documents
Evaluation of Coded Excitations for Autonomous Airborne Ultrasonic Inspection
2019
Unmanned Aerial Vehicles (UAVs) are receiving increasing attention for use in Non-Destructive Testing due to their ability to access areas where manual inspection is not practical. Contact-based UAV ultrasonic inspections grant the opportunity to remotely monitor the structural health of an industrial asset with enhanced internal integrity information. Ultrasonic inspection is a Non-Destructive Testing (NDT) method conventionally used in corrosion mapping. Surface contacting ultrasonic transducers provide enhanced structural integrity information. However, due to near-surface aerodynamic effects, angular sensitivity of the ultrasound probe and alignment error during autonomous inspections, …
Evaluation of a model of temporal weights in loudness judgments
2018
The onset of a sound receives a higher weight than later portions in time when its loudness is assessed, an effect commonly referred to as primacy effect. It is investigated if this effect can be predicted on the basis of an exponentially decaying function where the weight assigned to a temporal portion of a sound is the integral of this function over the segment duration. To test this model, temporal loudness weights were measured for sounds with different segment durations and total durations. The model successfully predicted essential aspects of the data.
On the variations of acoustic absorption peak with particle velocity in micro-perforated panels at high level of excitation.
2010
The acoustic behavior of micro-perforated panels (MPP) is studied theoretically and experimentally at high level of pressure excitation. A model based on Forcheimer's regime of flow velocity in the perforations is proposed. This model is valid at relatively high Reynolds numbers and low Mach numbers. The experimental method consists in measuring the acoustical pressure at three different positions in an impedance tube, the two measurement positions usually considered in an impedance tube and one measurement in the vicinity of the rear surface of the MPP. The impedance tube is equipped with a pressure driver instead of the usual loudspeaker and capable of delivering a high sound pressure lev…
Acoustic characterization of Silica aerogel clamped plates for perfect absorption purpose
2017
International audience; Silica aerogel has been widely studied as bulk material for its extremely low density and thermal conductivity. Plates or membranes made of this extremely soft materials exhibits interesting properties for sound absorption. A novel signal processing method for the characterization of an acoustic metamaterial made of silica aerogel clamped plates is presented. The acoustic impedance of a silica aerogel clamped plate is derived from the elastic theory for the flexural waves, while the transfer matrix method is used to model reflection and transmission coefficients of a single plate. Experimental results are obtained by using an acoustic impedance tube. The difference b…
Measurement of acoustic attenuation in South Pole ice
2010
Using the South Pole Acoustic Test Setup (SPATS) and a retrievable transmitter deployed in holes drilled for the IceCube experiment, we have measured the attenuation of acoustic signals by South Pole ice at depths between 190 m and 500 m. Three data sets, using different acoustic sources, have been analyzed and give consistent results. The method with the smallest systematic uncertainties yields an amplitude attenuation coefficient alpha = 3.20 \pm 0.57 km^(-1) between 10 and 30 kHz, considerably larger than previous theoretical estimates. Expressed as an attenuation length, the analyses give a consistent result for lambda = 1/alpha of ~1/300 m with 20% uncertainty. No significant depth or …
Mini-COVIDNet: Efficient Lightweight Deep Neural Network for Ultrasound Based Point-of-Care Detection of COVID-19
2021
Lung ultrasound (US) imaging has the potential to be an effective point-of-care test for detection of COVID-19, due to its ease of operation with minimal personal protection equipment along with easy disinfection. The current state-of-the-art deep learning models for detection of COVID-19 are heavy models that may not be easy to deploy in commonly utilized mobile platforms in point-of-care testing. In this work, we develop a lightweight mobile friendly efficient deep learning model for detection of COVID-19 using lung US images. Three different classes including COVID-19, pneumonia, and healthy were included in this task. The developed network, named as Mini-COVIDNet, was bench-marked with …
Subjective ranking of concert halls substantiated through orthogonal objective parameters.
2015
[EN] This paper studies the global subjective assessment, obtained from mean values of the results of surveys addressed to members of the audience of live concerts in Spanish auditoriums, through the mean values of the three orthogonal objective parameters (Tmid, IACCE3, and LEV), expressed in just noticeable differences (JNDs), regarding the best-valued hall. Results show that a linear combination of the relative variations of orthogonal parameters can largely explain the overall perceived quality of the sample. However, the mean values of certain orthogonal parameters are not representative, which shows that an alternative approach to the problem is necessary. Various possibilities are pr…
Ultrasonographic Detection of Vascularity of Focal Breast Lesions: Microvascular Imaging Versus Conventional Color and Power Doppler Imaging.
2021
To compare microvascular flow imaging (MVFI) to conventional Color-Doppler (CDI) and Power-Doppler (PDI) imaging in the detection of vascularity of Focal Breast Lesions (FBLs). A total of 180 solid FBLs (size: 3.5–45.2 mm) detected in 180 women (age: 21–87 years) were evaluated by means of CDI, PDI, and MVFI. Two blinded reviewers categorized lesion vascularity in absent or present, and vascularity pattern as (a) internal; (b) vessels in rim; (c) combined. The presence of a “penetrating vessel” was assessed separately. Differences in vascularization patterns (chi2 test) and intra- and inter-observer agreement (Fleiss method) were calculated. ROC analysis was performed to assess performance…
Measures of native and non-native rhythm in a quantity language.
2005
The traditional phonetic classification of language rhythm as stress-timed or syllable-timed is attributed to Pike. Recently, two different proposals have been offered for describing the rhythmic structure of languages from acoustic-phonetic measurements. Ramus has suggested a metric based on the proportion of vocalic intervals and the variability ( SD) of consonantal intervals. Grabe has proposed Pairwise Variability Indices (nPVI, rPVI) calculated from the differences in vocalic and consonantal durations between successive syllables. We have calculated both the Ramus and Grabe metrics for Latvian, traditionally considered a syllable rhythm language, and for Latvian as spoken by Russian l…
Human voice pitch measures are robust across a variety of speech recordings: methodological and theoretical implications
2021
Fundamental frequency ( f o ), perceived as voice pitch, is the most sexually dimorphic, perceptually salient and intensively studied voice parameter in human nonverbal communication. Thousands of studies have linked human f o to biological and social speaker traits and life outcomes, from reproductive to economic. Critically, researchers have used myriad speech stimuli to measure f o and infer its functional relevance, from individual vowels to longer bouts of spontaneous speech. Here, we acoustically analysed f o in nearly 1000 affectively neutral speech utterances (vowels, words, counting, greetings, read paragraphs and free spontaneous speech) produced by the same 154 men and women, ag…