Search results for " Analytical"
showing 10 items of 1453 documents
Reconsidering the accuracy of X-ray fluorescence and ion beam based methods when used to measure the thickness of ancient gildings
2017
Since at least 5000 years ago, gilding techniques have been used for decoration purposes or to make artefacts appear as made of solid gold. Investigation of ancient gildings inevitably requires measuring their thickness, which is usually done either through the observation of cross-sections or by methods such as Rutherford backscattering spectroscopy, particle-induced X-ray emission and X-ray fluorescence. Whereas the former method requires sampling, the latter ones are non-invasive and therefore preferable. These non-invasive methods, however, measure the number of atoms per unit area, which can be converted into thickness only if the density is known. So far this has not been considered a…
Molecular orbital studies on brominated diphenyl ethers. Part II—reactivity and quantitative structure–activity (property) relationships
2005
Polybrominated diphenyl ethers (PBDEs) are widely used as flame retardants and are increasingly turning up in the environment. Their structural similarities to polychlorinated biphenyls and thyroid hormones suggest they may be a risk to human health. The present study examines the reactivity of brominated diphenyl ethers (BDEs) on the basis of the electronic structures as calculated by semiempirical AM1 self-consistent field molecular orbital (SCF-MO) method. Frontier orbital energies were used to elucidate the reactivity of BDEs in electrophilic, nucleophilic and photolytic reactions. From an examination of the frontier electron densities, the regioselectivity, or orientation, of metabolic…
Detectability of cannabinoids in the serum samples of cannabis users: Indicators of recent cannabis use? A follow‐up study
2021
Forensic toxicologists are frequently required to predict the time of last cannabis consumption. Several studies suggested the utility of minor cannabinoids as indicators of recent cannabis use. Because several factors influence blood cannabinoid concentrations, the interpretation of serum cannabinoid concentrations remains challenging. To assess the informative value of serum cannabinoid levels in cannabis users (in total N = 117 patients, including 56 patients who stated an exact time of last cannabis use within 24 h before blood sampling), the detectability of cannabinoids, namely delta-9-tetrahydrocannabinol (delta-9-THC), 11-hydroxy-delta-9-THC, 11-nor-9-carboxy-delta-9-THC, cannabichr…
Benefits of solvent concentration pulses in retention time modelling of liquid chromatography
2019
The advantages and disadvantages of the use of isocratic experimental designs including transient increments of organic solvent (i.e., pulses) in the mobile phase(s) of lowest elution strength are explored with modelling purposes. For retained solutes, this type of mixed design offers similar or better predictive capability than gradient designs, shorter measurement time than pure isocratic designs, and retention model parameters that agree with those derived from pure isocratic experiments, with similar uncertainties. The predicted retention times are comparable to those offered by models adjusted from pure isocratic designs, and the solvent waste is appreciably lower. Under a practical st…
Use of semipermeable membrane devices for monitoring pesticides in indoor air.
2009
Abstract In this work, 40 pesticides from different categories were analyzed in the air of 20 indoor places that have an intensive use of pesticides. Passive sampling was carried out by using semipermeable membrane devices (SPMDs) deployed for 7 days. SPMDs were analyzed using microwave-assisted extraction and GC/MS. PCB-195 was used as an internal standard. Recoveries ranged between 81 and 108 for many compounds, with RSD values <11. Typical LOD values for 7 days of sampling were from 0.1 to 3.1 ng/m. Propamocarb, propoxur, carbosulfan, pirimicarb, metribuzin, metalaxyl, pendimethalin, oxadiazon, phenothrin, and permethrin were detected in 11 sampling sites, with air concentrations …
Global retention models and their application to the prediction of chromatographic fingerprints
2020
Abstract The resolution of samples containing unknown compounds of different nature, or without standards available, as is the case of chromatographic fingerprints, is still a challenge. Possibly, the most problematic aspect that prevents systematic method development is finding models that describe without bias the retention behaviour of the compounds in the samples. In this work, the use of global models (able to describe the whole sample) is proposed as an alternative to the use of individual models for each solute. Global models contain parameters that are specific for each solute, while other parameters ‒related to the column and solvent‒ are common for all solutes. A special regressio…
Protein dynamics observed by tunable mid-IR quantum cascade lasers across the time range from 10 ns to 1 s
2017
We have developed a spectrometer based on tunable quantum cascade lasers (QCLs) for recording time-resolved absorption spectra of proteins in the mid-infrared range. We illustrate its performance by recording time-resolved difference spectra of bacteriorhodopsin in the carboxylic range (1800–1700 cm− 1) and on the CO rebinding reaction of myoglobin (1960–1840 cm− 1), at a spectral resolution of 1 cm− 1. The spectrometric setup covers the time range from 4 ns to nearly a second with a response time of 10–15 ns. Absorption changes as low as 1 × 10− 4 are detected in single-shot experiments at t > 1 μs, and of 5 × 10− 6 in kinetics obtained after averaging 100 shots. While previous time-res…
Enzymatic, physicochemical, nutritional and phytochemical profile changes of apple (Golden Delicious L.) juice under supercritical carbon dioxide and…
2018
The impact of supercritical carbon dioxide (SCCD) (10-60 MPa/45 °C/30 min) and subsequent 10 weeks storage at 4 °C on polyphenol oxidase (PPO), peroxidase (POD) activities, phenolic profile, vitamin C, sugars, physicochemical properties of cloudy apple juices was investigated. No significant changes in sugars and total polyphenols were observed, whereas significant degradation (≈28%) of vitamin C and individual polyphenols (≈18%) was noted after SCCD treatment. After 4 weeks storage only 34% of vitamin C was retained and no vitamin C was detected after this time. Ten weeks of storage caused hydrolysis of sucrose in 15%, whereas degradation of individual polyphenols ranged from 43 to 50% dep…
Time-Gated Raman Spectroscopy for Quantitative Determination of Solid-State Forms of Fluorescent Pharmaceuticals
2018
Raman spectroscopy is widely used for quantitative pharmaceutical analysis, but a common obstacle to its use is sample fluorescence masking the Raman signal. Time-gating provides an instrument-based method for rejecting fluorescence through temporal resolution of the spectral signal and allows Raman spectra of fluorescent materials to be obtained. An additional practical advantage is that analysis is possible in ambient lighting. This study assesses the efficacy of time-gated Raman spectroscopy for the quantitative measurement of fluorescent pharmaceuticals. Time-gated Raman spectroscopy with a 128 X (2) X 4 CMOS SPAD detector was applied for quantitative analysis of ternary mixtures of sol…
In-situ high spatial resolution LA-MC-ICPMS 230Th/U dating enables detection of small-scale age inversions in speleothems
2017
Abstract We present an in-situ method for Th and U isotope measurements by laser ablation multi-collector inductively coupled plasma mass spectrometry (LA-MC-ICPMS) to determine possible age inversions of stalagmites, using a 213 nm Nd:YAG laser connected to an MC-ICPMS. Due to the low ion beam intensity of 230 Th (20–120 counts per second, cps), we carefully optimized the operating parameters to get highest possible ion beam intensities, i.e., laser fluence (25 J cm −2 ), spot size (110 μm), pulse repetition rate (20 Hz), scan speed (4 μm s −1 ), integration time (1000 s), and He and Ar gas flow (∼0.9 L min −1 and ∼0.6 L min −1 respectively). A precision (2 relative standard error, 2RSE) o…