Search results for " CIRCUIT"
showing 10 items of 634 documents
Necessary and sufficient conditions for frequency entrainment of quasi-sinusoidal injection-synchonised oscillators
1986
A method is presented which permits the first-approximation exact analysis of the dynamical stability of fundamental-mode injectionsynchronized oscillators (FISO's) characterized by a quasi-sinusoidal quasi-static behavior. By combining small parameter and stroboscopic transformation techniques, the phase-lock stability investigation of an nth-order system is reduced to the simple Hurwitz test on an nth degree polynomial easily obtainable from steady state describing quantities. On this basis, equations for critical locking are also derived, which demonstrate the existence of a pair of limit curves (Locus and Boundary) already conjectured and looked for in the past, but only with partial su…
A Portable Readout System for Microstrip Silicon Sensors (ALIBAVA)
2009
A readout system for microstrip silicon sensors has been developed. This system is able to measure the collected charge in one or two microstrip silicon sensors by reading out all the channels of the sensor(s), up to 256. The system can operate either with non-irradiated and irradiated sensors as well as with n-type and p-type microstrip silicon sensors. Heavily irradiated sensors will be used at the Super Large Hadron Collider, so this system can be used to research the performance of microstrip silicon sensors in conditions as similar as possible to the Super Large Hadron Collider operating conditions. The system has two main parts: a hardware part and a software part. The hardware part a…
A high resolution TDC subsystem
1994
A high resolution TDC subsystem was developed at the Institute for Nuclear Physics in Mainz. The TDC chip offers a time resolution of less than 300 ps and a programmable measurement range from O to 16 /spl mu/sec. The time measurement is done with a new, purely digital counting method. The chip can be operated in common start or common stop mode. In common start mode the chip is able to store up to 4 multiple hits per channel. The chip is used to build a transputer controlled subsystem for the measurement of the drift times of a vertical drift chamber. The design of the subsystem will be described and the first results from the tests of the prototype system will be presented. >
Heavy-Ion Microbeam Studies of Single-Event Leakage Current Mechanism in SiC VD-MOSFETs
2020
Heavy-ion microbeams are employed for probing the radiation-sensitive regions in commercial silicon carbide (SiC) vertical double-diffused power (VD)-MOSFETs with micrometer accuracy. By scanning the beam spot over the die, a spatial periodicity was observed in the leakage current degradation, reflecting the striped structure of the power MOSFET investigated. Two different mechanisms were observed for degradation. At low drain bias (gate and source grounded), only the gate-oxide (at the JFET or neck region) is contributing in the ion-induced leakage current. For exposures at drain–source bias voltages higher than a specific threshold, additional higher drain leakage current is observed in t…
The Mu3e Data Acquisition
2020
The Mu3e experiment aims to find or exclude the lepton flavour violating decay $\mu^+\to e^+e^-e^+$ with a sensitivity of one in 10$^{16}$ muon decays. The first phase of the experiment is currently under construction at the Paul Scherrer Institute (PSI, Switzerland), where beams with up to 10$^8$ muons per second are available. The detector will consist of an ultra-thin pixel tracker made from High-Voltage Monolithic Active Pixel Sensors (HV-MAPS), complemented by scintillating tiles and fibres for precise timing measurements. The experiment produces about 100 Gbit/s of zero-suppressed data which are transported to a filter farm using a network of FPGAs and fast optical links. On the filte…
The MuPix System-on-Chip for the Mu3e Experiment
2016
Nuclear instruments & methods in physics research / A 845, 194 - 198 (2016). doi:10.1016/j.nima.2016.06.095
Performance of the front-end electronics of the ANTARES neutrino telescope
2010
ANTARES is a high-energy neutrino telescope installed in the Mediterranean Sea at a depth of 2475 m. It consists of a three-dimensional array of optical modules, each containing a large photomultiplier tube. A total of 2700 front-end ASICs named Analogue Ring Samplers (ARS) process the phototube signals, measure their arrival time, amplitude and shape as well as perform monitoring and calibration tasks. The ARS chip processes the analogue signals from the optical modules and converts information into digital data. All the information is transmitted to shore through further multiplexing electronics and an optical link. This paper describes the performance of the ARS chip; results from the fu…
Demonstration of background rejection using deep convolutional neural networks in the NEXT experiment
2021
[EN] Convolutional neural networks (CNNs) are widely used state-of-the-art computer vision tools that are becoming increasingly popular in high-energy physics. In this paper, we attempt to understand the potential of CNNs for event classification in the NEXT experiment, which will search for neutrinoless double-beta decay in Xe-136. To do so, we demonstrate the usage of CNNs for the identification of electron-positron pair production events, which exhibit a topology similar to that of a neutrinoless double-beta decay event. These events were produced in the NEXT-White high-pressure xenon TPC using 2.6 MeV gamma rays from a Th-228 calibration source. We train a network on Monte Carlo-simulat…
AGATA-Advanced GAmma Tracking Array
2012
WOS: 000300864200005
Detector characterization and first coincidence tests of a Compton telescope based on LaBr3 crystals and SiPMs
2011
International audience; A Compton telescope for dose monitoring in hadron therapy consisting of several layers of continuous LaBr3 crystals coupled to silicon photomultiplier (SiPM) arrays is under development within the ENVISION project. In order to test the possibility of employing such detectors for the telescope, a detector head consisting of a continuous 16 mm×18 mm×5 mm LaBr3 crystal coupled to a SiPM array has been assembled and characterized, employing the SPIROC1 ASIC as readout electronics. The best energy resolution obtained at 511 keV is 6.5% FWHM and the timing resolution is 3.1 ns FWHM. A position determination method for continuous crystals is being tested, with promising res…