Search results for " CIRCUIT"
showing 10 items of 634 documents
Operational experience with a large detector system using silicon strip detectors with double sided readout
1992
Abstract A large system of silicon strip detectors with double sided readout has been successfully commissioned over the course of the last year at the e + e − collider LEP. The readout of this 73 728 channel system is performed with custom designed VLSI charge sensitive amplifier chips (CAMEX64A). An overall point resolution of 12 μm on both sides has been acheived for the complete system. The most important difficulties during the run were beam losses into the detector, and a chemical agent deposited onto the electronics; however, the damage from these sources was understood and brought under control. This and other results of the 1991 data-taking run are described with special emphasis o…
First Compton telescope prototype based on continuous LaBr3-SiPM detectors
2013
Abstract A first prototype of a Compton camera based on continuous scintillator crystals coupled to silicon photomultiplier (SiPM) arrays has been successfully developed and operated. The prototype is made of two detector planes. The first detector is made of a continuous 16×18×5 mm 3 LaBr 3 crystal coupled to a 16-elements SiPM array. The elements have a size of 3×3 mm 3 in a 4.5×4.05 mm 2 pitch. The second detector, selected by availability, consists of a continuous 16×18×5 mm 3 LYSO crystal coupled to a similar SiPM array. The SPIROC1 ASIC is employed in the readout electronics. Data have been taken with a 22 Na source placed at different positions and images have been reconstructed with…
Preliminary design of the top cap of DEMO Water-Cooled Lithium Lead breeding blanket segments
2020
Abstract Within the framework of EUROfusion R&D activity, a research campaign has been carried out at the University of Palermo, in close cooperation with ENEA labs, in order to preliminary design the top cap foreseen for the DEMO Water-Cooled Lithium Lead (WCLL) breeding blanket segments. Due to the high heat and pressure loads acting on such component, its design results particularly demanding and a specific multi-physics approach is needed, covering several aspects from thermal-hydraulics to structural assessments. Preliminary detailed CAD model of the cap integrated into the upper region of the WCLL breeding blanket outboard central segment has been set-up, equipped with proper cooling …
Transient analysis of "2 inch Direct Vessel Injection line break" in SPES-2 facility by using TRACE code
2015
In the past few decades a lot of theoretical and experimental researches have been done to understand the physical phenomena characterizing nuclear accidents. In particular, after the Three Miles Island accident, several reactors have been designed to handle successfully LOCA events. This paper presents a comparison between experimental and numerical results obtained for the “2 inch Direct Vessel Injection line break” in SPES-2. This facility is an integral test facility built in Piacenza at the SIET laboratories and simulating the primary circuit, the relevant parts of the secondary circuits and the passive safety systems typical of the AP600 nuclear power plant. The numerical analysis her…
A dynamic load-balancing algorithm for molecular dynamics simulation on multi-processor systems
1991
Abstract A new algorithm for dynamic load-balancing on multi-processor systems and its application to the molecular dynamics simulation of the spinodal phase separation are presented. The load-balancer is distributed among the processors and embedded in the application itself. Tests performed on a transputer network show that the load-balancer behaves almost ideally in this application. The same approach can be easily extended to different multi-processor topologies or applications.
Concatenated logic functions using nanofluidic diodes with all-electrical inputs and outputs
2018
[EN] Nanopore-based logical schemes in ionic solutions typically involve single gates and chemical inputs. The design of computer-like functions requires the consecutive concatenation of several gates and the use of electrical potentials and currents to facilitate the downstream transfer of electrochemical information. We have demonstrated the robust operation of concatenated logic functions using biomimetic nanofluidic diodes based on single pore membranes. To this end, we have implemented first the logic functions AND and OR with combinations of single nanopores using all-electrical input and output signals. The concatenation of these gates allows the output of the OR gate to act as one o…
PSA Depletion Induces the Differentiation of Immature Neurons in the Piriform Cortex of Adult Mice
2021
Immature neurons are maintained in cortical regions of the adult mammalian brain. In rodents, many of these immature neurons can be identified in the piriform cortex based on their high expression of early neuronal markers, such as doublecortin (DCX) and the polysialylated form of the neural cell adhesion molecule (PSA-NCAM). This molecule plays critical roles in different neurodevelopmental events. Taking advantage of a DCX-CreERT2/Flox-EGFP reporter mice, we investigated the impact of targeted PSA enzymatic depletion in the piriform cortex on the fate of immature neurons. We report here that the removal of PSA accelerated the final development of immature neurons. This was revealed by a h…
Light absorption and conversion in solar cell based on Si:O alloy
2013
Thin film Si:O alloys have been grown by plasma enhanced chemical vapor deposition, as intrinsic or highly doped (1 to 5 at. % of B or P dopant) layers. UV-visible/near-infrared spectroscopy revealed a great dependence of the absorption coefficient and of the optical gap (Eg) on the dopant type and concentration, as Eg decreases from 2.1 to 1.9 eV, for the intrinsic or highly p-doped sample, respectively. Thermal annealing up to 400 °C induces a huge H out-diffusion which causes a dramatic absorption increase and a reduction of Eg, down to less than 1.8 eV. A prototypal solar cell has been fabricated using a 400 nm thick, p-i-n structure made of Si:O alloy embedded within flat transparent c…
<title>Optical sensing for early cardiovascular diagnostics</title>
2000
A sensor device for noninvasive detection and analysis of the pulsating blood flow waveforms by means of the reflective single-period photoplethysmorgraphy (SPPPG) technique has been designed and clinically tested. The sensor is operated jointly with any standard PC, by connecting the sensor head to the AD-card and using a separate hard disc with the signal processing software; all circuits are fed by the PC power supply. After processing, normalized shape of the mean SPPPG signal and its parameters are calculated and displayed; the measurement/processing time does not exceed 2 minutes. The clinically detected SPPPG signal shapes and corresponding parameters are presented and discussed. The…
Halide perovskite amplifiers integrated in polymer waveguides
2016
Semiconductor organometallic halide perovskites (CH 3 NH 3 PbX 3 , X=Cl, Br, I) (HPVK) have emerged as a new promising material able to improve the optoelectronic technology performance. Although this material has mostly been applied to improve the efficiency of photovoltaic devices, it also shows amazing properties for photonic applications. In particular, HPVK exhibits high photoluminescence (PL) quantum yield (up to 70%) at room temperature together with a tunable band-gap controlled by its chemical composition. In addition, since HPVKs is deposited in solution at room conditions, it can be easily incorporated in different photonic structures to efficiently exploit its emission propertie…