Search results for " CT"
showing 10 items of 306 documents
Efficacy of single-source rapid kV-switching dual-energy CT for characterization of non-uric acid renal stones: a prospective ex vivo study using ant…
2019
Purpose To investigate the accuracy of rapid kV-switching single-source dual-energy computed tomography (rsDECT) for prediction of classes of non-uric-acid stones. Materials and methods Non-uric-acid renal stones retrieved via percutaneous nephrolithotomy were prospectively collected between January 2017 and February 2018 in a single institution. Only stones >= 5 mm and with pure composition (i.e., >= 80% composed of one component) were included. Stone composition was determined using Fourier Transform Infrared Spectroscopy. The stones were scanned in 32-cm-wide anthropomorphic whole-body phantom using rsDECT. The effective atomic number (Zeff), the attenuation at 40 keV (HU40), 70 ke…
Characterization of Small Incidental Indeterminate Hypoattenuating Hepatic Lesions: Added Value of Single-Phase Contrast-Enhanced Dual-Energy CT Mate…
2018
OBJECTIVE. The objective of this study is to determine whether single-phase contrast-enhanced dual-energy CT (DECT) material attenuation analysis improves the characterization of small (< 2.0 cm) incidental indeterminate hypoattenuating hepatic lesions, compared with conventional single-energy CT evaluation. MATERIALS AND METHODS. This retrospective study involved 55 patients (24 men and 31 women; mean [± SD] age, 63.9 ± 15.3 years) with 77 incidental hypoattenuating hepatic lesions (59 benign and 18 malignant lesions) measuring 0.5–2.0 cm who underwent single-phase contrast-enhanced DECT of the abdomen for pain. For each lesion, attenuation measurements were obtained using blended 120-k…
Bowel wall thickening: inquire or not inquire? Our guidelines
2018
Introduction Bowel wall thickening is not an uncommon finding among patient undergoing abdomen CT scan. It may be caused by neoplastic, inflammatory, infectious or ischaemic conditions but also be a normal variant. Although specific radiologic patterns may direct to a precise diagnosis, occasionally misidentification may occur. Thus, in the absence of guidelines, further and not always needed diagnostic procedures (colonoscopy, esophagogastroduodenoscopy or capsule endoscopy) are performed. Patients and methods We conducted a retrospective study on data collected from May 2016 to June 2017. We selected 40 adult patients, admitted in Emergency Department with "abdominal pain" and undergone a…
Cerebellar Contribution to Mental Rotation: a cTBS Study
2013
A cerebellar role in spatial information processing has been advanced even in the absence of physical manipulation, as occurring in mental rotation. The present study was aimed at investigating the specific involvement of left and right cerebellar hemispheres in two tasks of mental rotation. We used continuous theta burst stimulation to downregulate cerebellar hemisphere excitability in healthy adult subjects performing two mental rotation tasks: an Embodied Mental Rotation (EMR) task, entailing an egocentric strategy, and an Abstract Mental Rotation (AMR) task entailing an allocentric strategy. Following downregulation of left cerebellar hemisphere, reaction times were slower in comparison…
Thromboembolic complications of COVID-19: the combined effect of a pro-coagulant pattern and an endothelial thrombo-inflammatory syndrome.
2020
Coronavirus disease 2019 (COVID-19) is a newly emerging human infectious disease that has quickly become a worldwide threat to health, mainly causing severe acute respiratory syndrome. In addition to the widely described respiratory syndrome, COVID-19 may cause life-treating complications directly or indirectly related to this infection. Among these, thrombotic complications have emerged as an important issue in patients with COVID-19 infection, particularly in patients in intensive care units. Thrombotic complications due to COVID-19 are likely to occur due to a pro-coagulant pattern encountered in some of these patients or to a progressive endothelial thrombo-inflammatory syndrome causing…
Value of contrast-enhanced MR angiography and helical CT angiography in chronic thromboembolic pulmonary hypertension.
2003
The aim of this study was to evaluate the diagnostic value of contrast-enhanced MR angiography (ce MRA) and helical CT angiography (CTA) of the pulmonary arteries in the preoperative workup of patients with chronic thromboembolic pulmonary hypertension (CTEPH). The ce MRA and CTA studies of 32 patients were included in this retrospective evaluation. Image quality was scored by two independent blinded observers. Data sets were assessed for number of patent segmental, subsegmental arteries, and number of vascular segments with thrombotic wall thickening, intraluminal webs, and abnormal proximal to distal tapering. Image quality for MRA/CTA was scored excellent in 16 of 16, good in 11 of 14, m…
Bolus-enhanced renal spiral CT: technique, diagnostic value and drawbacks
1994
Abstract In addition to pre- and postcontrast renal CT scans, early bolus-enhanced spiral scans during demarcation of the corticomedullary junction were acquired in 85 patients. The diagnostic value and drawbacks of the three imaging series in the evaluation of renal disease were assessed. Renal calcifications and calculus disease detected at precontrast scans (18%) were obscured after contrast administration and excretion in most cases. In the detection of renal lesions bolus-enhanced spiral CT and delayed postcontrast scans had an identical diagnostic yield (94%). Bolus-enhanced spiral CT was superior in the assessment of lesion vascularity and vascular anatomy as well as opacification of…
Diagnostic performance of reformatted isotropic thin-section helical CT images in the detection of superior semicircular canal dehiscence
2017
Purpose The purpose of this article is to assess the diagnostic performance of computed tomography (CT) reformatted images for detection of superior semicircular canal (SSC) dehiscence. Material and methods Forty-two patients, with sound- and/or pressure-induced vestibular symptoms, and 42 control participants underwent helical CT examination with a highly collimated beam (0.5 mm). Reformatted images of the vestibular labyrinth were obtained in the standard axial and coronal planes (group A images), and in a plane parallel and perpendicular to the SSC (group B images). Diagnostic performance obtained by evaluating the group A images alone and the group B images alone was analyzed by using t…
Forty-slice MDCT enteroclysis: evaluation after oral administration of isotonic solution in Crohn's disease.
2007
Objective. The aim of this study was to evaluate the accuracy of multidetector computed tomography (MDCT) enteroclysis after oral hyperhydration with isotonic solution in detecting bowel wall alterations in patients with Crohn’s disease. Materials and methods. Twenty-eight patients with a diagnosis of Crohn’s disease established by ileocolonoscopy and histology were enrolled in the study; 15 patients with negative ileocolonoscopy served as controls. In all cases, MDCT enteroclysis was performed after oral administration of 2,000 ml of isotonic solution and intravenous administration of N-butylscopolamine. Axial, isotropic multiplanar and volume-rendered reconstructions were used to evaluate…
Liver "Compliance": A previously unrecognized preoperative predictor of small-for-size syndrome in adult living donor liver transplantation
2008
The purpose of this study was to investigate the effect of liver compliance on computed tomography (CT) volumetry and to determine its association with postoperative small-for-size syndrome (SFSS).Unenhanced, arterial, and venous phase CT images of 83 consecutive living liver donors who underwent graft hepatectomy for adult-to-adult living donor liver transplantation (ALDLT) were prospectively subjected to three-dimensional (3-D) CT liver volume calculations and virtual 3-D liver partitioning. Graft volume estimates based on 3-D volumetry, which subtracted intrahepatic vascular volume from the "smallest" (native) unenhanced and the "largest" (venous) CT phases, were subsequently compared wi…