Proteolytic cleavage of soybean Bowman-Birk inhibitor monitored by means of high-performance capillary electrophoresis. Implications for the mechanis…

1996

The hydrolysis of the soybean Bowman-Birk inhibitor in the presence of catalytic amounts of bovine trypsin and the formation of the non-covalent enzyme-inhibitor complex with an equimolar amount of enzyme are monitored by means of high-performance capillary electrophoresis (HPCE). The inhibitor is cleaved in the trypsin-reactive and more slowly in the chymotrypsin-reactive subdomain. HPCE proves itself as the only reliable analytical tool to monitor these reactions in clear contrast to classical electrophoretic, chromatographic and enzymatic methods. The most efficient separation of the intact and the two active site cleaved forms of the inhibitor was achieved in borate buffer at pH 10.0. T…

chemistry.chemical_classificationBinding SitesChromatographybiologyChemistryHydrolysisMolecular Sequence DataBiophysicsElectrophoresis CapillaryActive siteCleavage (embryo)BiochemistryCatalysisProtein Structure TertiaryKineticsElectrophoresisHydrolysisReaction rate constantEnzymeCapillary electrophoresisBiochemistryEnzyme inhibitorbiology.proteinAmino Acid SequenceTrypsin Inhibitor Bowman-Birk SoybeanJournal of Biochemical and Biophysical Methods
researchProduct

Life-time studies with capillary electrochromatography columns operated under different conditions.

2000

A test system has been established to permit the monitoring of the life-time performance of several reversed- phase capillary electrochromatography (CEC) columns. The retention factors, k(cec), peak symmetry coefficients, lambda(sym), and column efficiencies, N, of three neutral n-alkylbenzene analytes, namely ethyl-, n-butyl- and n-pentylbenzenes, were determined for Hypersil 3 microm n-octylsilica and n-octadecylsilica packed into CEC capillary columns of 100 microm I.D., with a packed length of 250 mm, and a total length of 335 mm. The performances of these CEC capillary columns were examined for a variety of eluents with pH values ranging between pH 2.0 - 8.0, similar to those employed …

chemistry.chemical_classificationCapillary electrochromatographyChromatographyCapillary actionOrganic ChemistryAnalytical chemistryGeneral MedicineReversed-phase chromatographyHydrogen-Ion ConcentrationBiochemistryAnalytical Chemistrychemistry.chemical_compoundColumn chromatographyHydrocarbonchemistryElectrochromatographyAlkylbenzenesTheoretical plateChromatography Micellar Electrokinetic CapillaryJournal of chromatography. A
researchProduct

Capillary electrochromatography analysis of hormonal cyclic and linear peptides.

2001

The retention behavior of linear and cyclic peptides has been studied by capillary electrochromatography (CEC) with a variety of different n-alkyl silica reversed-phase sorbents and also with mixed-mode phases containing both strong cation-exchange (sulfonic acid) and n-alkyl groups bonded onto the silica surface, using eluents ranging from pH 2.0 to pH 5.0. Depending upon the amino acid sequence, electrochromatographic retention of the peptides was strongly affected by the composition of the eluent, its pH value, and the choice of sorbent packed into the capillaries. The dominant separation processes operating with these charged analytes could be modulated inter alia by the content of orga…

chemistry.chemical_classificationCapillary electrochromatographyChromatographySilicon dioxideSulfonic acidSilicon DioxidePeptides CyclicCyclic peptideHormonesAnalytical Chemistrychemistry.chemical_compoundColumn chromatographyCapillary electrophoresischemistryElectrochromatographyAcetonitrileOligopeptidesChromatography Micellar Electrokinetic CapillaryAnalytical chemistry
researchProduct

Discontinuous electrokinetic chromatography of parabens using different substituted resonances as pseudostationary phases

1999

Resorcarene derivatives, negatively charged even at moderate pH, were synthesized and employed as pseudostationary phases to achieve mobilities exceeding that of the electroosmotic flow. Under these conditions, a discontinuous electrolyte system was developed which allows the separation of four uncharged homologous 4-hydroxybenzoic esters (parabens) within a zone of resorcarene electrolyte, and the detection of these UV active compounds in a resorcarene-free zone, free from the high UV background absorbance of the resorcarenes. Resorcarenes, with differently charged functionalities (carboxylate and phosphate groups) to provide the electrophoretic mobility and with alkyl residues of differen…

chemistry.chemical_classificationChromatographyClinical BiochemistryParabensElectrolyteResorcinareneBiochemistryAnalytical ChemistryAbsorbanceElectrophoresischemistry.chemical_compoundElectrokinetic phenomenachemistryCarboxylateSelectivityAlkylChromatography Micellar Electrokinetic CapillaryElectrophoresis
researchProduct

Determination of cationic surfactants by capillary zone electrophoresis and micellar electrokinetic chromatography with deoxycholate micelles in the …

2000

Mixtures of the cationic surfactants benzalkonium chloride (BKC) and cetylpyridinium chloride (CPC) were quickly resolved and reproducibly and reliably determined by using background electrolytes (BGEs) containing 80 mM borate, pH 8.5, bile salts and large concentrations of an organic solvent. When the bile salt is present, the separation mechanism changes from capillary zone electrophoresis (CZE) to a mixed micellar electrokinetic chromatography (MEKC)-CZE, with predominant MEKC interactions, which lead to an excellent resolution of all the solutes, including the C12-C18 homologues of BKC and CPC. A BGE containing 50 mM sodium deoxycholate and 30% ethanol for an extreme resolution, or 20% …

chemistry.chemical_classificationChromatographyResolution (mass spectrometry)Organic ChemistryCationic polymerizationSalt (chemistry)General MedicineCetylpyridinium chlorideBiochemistryMicelleMicellar electrokinetic chromatographyAnalytical Chemistrychemistry.chemical_compoundBenzalkonium chlorideSurface-Active AgentsCapillary electrophoresischemistryCationsmedicineSolventsMicellesmedicine.drugChromatography Micellar Electrokinetic CapillaryDeoxycholic AcidJournal of chromatography. A
researchProduct

Determination of optical purity of phosphonic acid analogues of aromatic amino acids by capillary electrophoresis with alpha-cyclodextrin.

2000

A simple and efficient method for the determination of enantiomeric purity of structurally diverse phosphonic and phosphinic acid analogues of phenylalanine and phenylglycine using capillary electrophoresis is presented. These preliminary studies indicated that the enantiomer separation is strongly dependent on the structure of the aminophosphonic acid.

chemistry.chemical_classificationCyclodextrinsalpha-CyclodextrinsChromatographyCyclodextrinOrganic ChemistryOrganophosphonatesElectrophoresis CapillaryPhenylalanineGeneral MedicineBiochemistryAnalytical ChemistryAmino acidchemistry.chemical_compoundCapillary electrophoresischemistryBenzene derivativesAromatic amino acidsphosphonic acidsEnantiomerenantiomer separationAmino AcidsEnantiomeric excessJournal of chromatography. A
researchProduct

Fast determination of prominent carotenoids in tomato fruits by CEC using methacrylate ester-based monolithic columns.

2007

In this study, the major carotenoids (beta-carotene and lycopene) present in tomato fruits were analyzed by CEC with a methacrylate ester-based monolithic column. The effects of the porogenic solvent ratio, and the hydrophobicity of bulk monomer employed were examined on carotenoids separations. A fast separation of these analytes was achieved in less than 5.0 min in a mobile phase containing 35% THF, 30% ACN, 30% methanol, and 5% of a 5 mM Tris aqueous buffer, pH 8, with lauryl methacrylate-based monoliths. The CEC method was evaluated in terms of detection limit and reproducibility (retention time, area, and column preparation) with values below 1.6 microg/mL and 7.2%, respectively. The p…

chemistry.chemical_classificationDetection limitAnalyteMonolithic HPLC columnChromatographyTime FactorsChemistryClinical BiochemistryBreedingMethacrylatebeta CaroteneBiochemistryCarotenoidsLycopeneAnalytical ChemistrySolventchemistry.chemical_compoundLycopeneSolanum lycopersicumFruitMethacrylatesMethanolCarotenoidChromatography Micellar Electrokinetic CapillaryElectrophoresis
researchProduct

Determination of major carotenoids in vegetables by capillary electrochromatography.

2006

A simple and rapid method for the isocratic separation and determination of carotenoids (carotenes and xanthophylls) in vegetables by CEC is described. The capillary column (100 microm ID, 25 cm effective length) was packed with 3 microm Hypersil ODS particles. The optimized mobile phase contained 60% ACN, 35% THF and 5% of a 5 mM Tris aqueous buffer of pH 8. beta-Carotene, lycopene and lutein were separated with efficiencies of 66 000-128 000 plates/m within a short time (less than 12 min for the last peak eluted, 13/13'-cis-beta-carotene). An excellent resolution of the three carotenoids, as well as partial resolution of their geometrical isomers, was achieved. Application to the determin…

chemistry.chemical_classificationLuteinCapillary electrochromatographyChromatographyResolution (mass spectrometry)Molecular StructureElutionReproducibility of ResultsFiltration and SeparationStereoisomerismCarotenoidsLycopeneAnalytical Chemistrychemistry.chemical_compoundElectrochromatographychemistryXanthophyllVegetablesCarotenoidChromatography Micellar Electrokinetic CapillaryJournal of separation science
researchProduct

Determining sulfur-containing amino acids by capillary electrophoresis: A fast novel method for total homocyst(e)ine human plasma

1999

A high-performance capillary electrophoresis (HPCE) method based on laser-induced fluorescence detection is presented here. It enables the determination of sulfur-containing amino acids within 15 min. Fluorescence of sulfur-containing amino acids in plasma is linear over a range of 50-150 micromol/L for L-methionine, 5-100 micromol/L for L-homocysteine, and 50-200 micromol/L for L-cysteine. For homocysteine, we were able to detect 1 fmol injected, equivalent to a plasma concentration of 10 nmol/L. A similar sensitivity is present for cysteine, an even lower one being found for methionine. The intra- and interassay relative standard deviations are < 1%. High-performance liquid chromatography…

chemistry.chemical_classificationMethionineChromatographyMolecular StructureHomocysteineClinical BiochemistryElectrophoresis Capillarychemistry.chemical_elementBiochemistrySulfurFluorescenceHigh-performance liquid chromatographyAnalytical ChemistryAmino acidchemistry.chemical_compoundCapillary electrophoresischemistryHumansAmino AcidsHomocysteineChromatography High Pressure LiquidSulfurCysteineElectrophoresis
researchProduct

Novel acrylamido monomers with higher hydrophilicity and improved hydrolytic stability: III. DNA separations by capillary electrophoresis in poly(N-a…

1996

Separation of DNA fragments in a novel polymer network, consisting of N-acryloylaminopropanol (AAP) is reported. The performance of this novel monomer, as a sieving liquid polymer in capillary zone electrophoresis, was evaluated. In 50 microns ID capillaries, an 8% solution of poly (AAP) can afford apex-resolution of the 123/124 bp adjacent pair of DNA fragments in marker V, typically unresolved in any poly (acrylamide) formulation. It is proposed that the distal-OH group in the AAP molecule can form transient H-bonds with the DNA double helix. Molecular modeling shows a meandering structure for poly (AAP), lacing the walls of half a cylinder, with kinks protruding at regular intervals, pot…

chemistry.chemical_classificationModels MolecularMolecular massClinical BiochemistryAcrylic ResinsElectrophoresis CapillaryPolymerDNABiochemistryAnalytical Chemistrychemistry.chemical_compoundElectrophoresisMonomerCapillary electrophoresischemistryAcrylamidePolymer chemistryMoleculeGelsDNA
researchProduct