Search results for " Capillary"

showing 10 items of 161 documents

Reliability of automated optical determination of capillary refill time

2021

The present study is devoted to assessment of automated optical capillary refill time determination by custom developed optoelectronic device prototype. Study comprised fifteen healthy volunteers; To induce capillary refill time changes the hand position challenge was utilized. During rest conditions slight inter-subject variation was observed: T90 (0.75±0.27 s), TSTB (2.20±0.58 s) and temperature at the measurement site (32.21±1.87 Co), however during hand position challenge results were more consistent. Rising hand substantially increased, while lowering slightly decreased capillary refill time. We conclude that automated determination of refill time have high clinical potential, however …

Hand positionTime changesLight intensitymedicine.diagnostic_testComputer scienceDecreased capillary refill timeHealthy volunteersmedicineCapillary refillMeasurement siteReliability (statistics)Biomedical engineeringBiophotonics Congress 2021
researchProduct

Evaluation of enantioselective binding of basic drugs to plasma by ACE.

2007

The present paper deals with the evaluation of the stereoselective binding of antihistamines (brompheniramine, chlorpheniramine, hydroxyzine, orphenadrine and phenindamine), phenothiazines (promethazine and trimeprazine) and a local anesthetic (bupivacaine) to human plasma proteins. Since all of them are drugs highly bound to proteins, a methodology to determine the bound fraction of each drug enantiomer was proposed. This methodology includes the incubation of samples containing plasma and racemic drug, ultrafiltration of the mixture and the chiral separation of enantiomers in the bound drug fraction using affinity EKC (AEKC)-partial filling technique and HSA as chiral selector. The result…

HydroxyzinePhenindamineChromatographyChemistryClinical BiochemistryTrimeprazineElectrophoresis CapillaryUltrafiltrationStereoisomerismBlood ProteinsBrompheniramineBiochemistryBlood proteinsBupivacaineAnalytical ChemistryPromethazineEvaluation Studies as TopicmedicineOrphenadrineHistamine H1 AntagonistsHumansEnantiomermedicine.drugElectrophoresis
researchProduct

High-performance liquid chromatographic, capillary electrophoretic and capillary electrophoretic–electrospray ionisation mass spectrometric analysis …

2002

Systems for efficient separation of selected alkaloid groups by high performance liquid chromatography (HPLC), capillary electrophoresis (CE) and capillary electrophoresis coupled with electrospray ionisation mass spectrometry (CE-ESI-MS) are described. The optimized HPLC system was applied for the separation of 23 standard indole alkaloids as well as for qualitative and quantitative analyses of crude alkaloid extracts of Rauvolfia serpentina X Rhazya stricta hybrid cell cultures. The developed conditions for CE analysis proved to be efficient for separation of mixtures of standard indole and beta-carboline alkaloids. The described buffer system is also applicable in the combination of CE w…

Indole testSpectrometry Mass Electrospray IonizationElectrosprayChromatographyMolecular StructurebiologyIndole alkaloidChemistryOrganic ChemistryElectrophoresis CapillaryGeneral Medicinebiology.organism_classificationMass spectrometryBiochemistryHigh-performance liquid chromatographyAnalytical ChemistryAlkaloidsCapillary electrophoresisRauvolfia serpentinaQuantitative analysis (chemistry)Chromatography High Pressure LiquidJournal of Chromatography A
researchProduct

Determination of urea-derived pesticides in fruits and vegetables by solid-phase preconcentration and capillary electrophoresis

2001

A multiresidue analytical method based on solid-phase extraction (SPE) enrichment combined with capillary electrophoresis (CE), using micellar electrokinetic capillary chromatography (MEKC), was developed to determine ten substituted urea pesticides in orange and tomato samples. Several factors such as pH, composition and concentration of the buffer, concentration of surfactant, addition of organic solvent, and working voltage were optimized to obtain the best compound separation in the shortest time. Separation can be achieved in 7 min using a micellar aqueous pH 9 buffer composed of 4 mM borate and 35 mM sodium dodecyl sulfate. After an SPE procedure, which provided a 10-fold enrichment, …

InsecticidesClinical BiochemistryFood ContaminationBiochemistryMicellar electrokinetic chromatographyAnalytical Chemistrychemistry.chemical_compoundCapillary electrophoresisVegetablesUreamedia_common.cataloged_instanceSolid phase extractionPesticidesSodium dodecyl sulfateEuropean unionMicellesmedia_commonDetection limitChromatographyAqueous solutionHerbicidesMethanolElectrophoresis CapillarySodium Dodecyl SulfatechemistryFruitEnrichment factorELECTROPHORESIS
researchProduct

Comparison between sodium dodecylsulphate and cetyltrimethylammonium bromide as mobile phases in the micellar liquid chromatography determination of …

2004

The retention behaviour of non-steroidal anti-inflammatory drugs (NSAIDs) using micellar mobile phases of sodium dodecylsulphate (SDS) is studied and compared with that observed with micellar mobile phases of cetyltrimethylammonium bromide (CTAB). A liquid chromatographic procedure for the determination of acemetacin, diclofenac, indomethacin, ketoprofen, naproxen and tolmetin in pharmaceutical preparations is described. The proposed system uses a Kromasil C18 analytical column and a solution of 0.15 M SDS at pH 3 with 10% 1-propanol as mobile phase. Under these conditions, the studied NSAIDs elute between 6 and 10 min at a 1 mL min(-1) flow rate. Limits of detection (LOD) are lower than 0.…

KetoprofenNaproxenSodiumClinical BiochemistryAcemetacinPharmaceutical Sciencechemistry.chemical_elementAnalytical Chemistrychemistry.chemical_compoundBromideDrug DiscoverymedicineSpectroscopyChromatography Micellar Electrokinetic CapillaryDetection limitChromatographyElutionCetrimoniumAnti-Inflammatory Agents Non-SteroidalSodium Dodecyl SulfateReference StandardsSolutionschemistryMicellar liquid chromatographyCalibrationCetrimonium CompoundsIndicators and ReagentsSpectrophotometry Ultravioletmedicine.drugJournal of pharmaceutical and biomedical analysis
researchProduct

O2Transport in Skeletal Muscle: Development of Concepts and Current State

1994

When comparing oxygen consumption rates(V O2) of various organs — as shown in Fig. 1 —skeletal muscle is exceptional in two respects: Its consumption rate attains the second largest absolute value of all organs and may vary between rest (0.2 mlO 2.100g-1’• min -1 ) and maximum performance (16 m1O 2.100g-1 • min -1 for electrical stimulation) by a factor of 80, thus covering a range that is by far larger than in any other tissue. In order to understand muscle O 2 transport one has to identify transport mechanisms and evaluate their importance towards bringing about the observed high O 2 fluxes and allowing for their enormous variability.

Longitudinal diffusionmedicine.anatomical_structureChemistryStimulation ratemedicineBiophysicsSkeletal muscleFunctional capillary densityCurrent (fluid)
researchProduct

Polymeric monolithic microcartridges with gold nanoparticles for the analysis of protein biomarkers by on-line solid-phase extraction capillary elect…

2020

In this study, polymeric monoliths with gold nanoparticles (AuNP@monolith) were investigated as microcartridges for the analysis of protein biomarkers by on-line solid-phase extraction capillary electrophoresis-mass spectrometry (SPE-CE-MS). “Plug-and-play” microcartridges (7 mm) were prepared from a glycidyl methacrylate (GMA)-based monolithic capillary column (5 cm x 250 µm i.d.), which was modified with ammonia and subsequently functionalized with gold nanoparticles (AuNPs). The performance of these novel microcartridges was evaluated with human transthyretin (TTR), which is a protein related to different types of familial amyloidotic polyneuropathies (FAP). Protein retention depended on…

MASS SPECTROMETRYPolymersMetal NanoparticlesOr010402 general chemistryMass spectrometry01 natural sciencesBiochemistryCapillary electrophoresis–mass spectrometryMass SpectrometryAnalytical Chemistry//purl.org/becyt/ford/1 [https]Capillary electrophoresisCAPILLARY ELECTROPHORESISLimit of DetectionElectroforesi capil·lar//purl.org/becyt/ford/1.4 [https]HumansPrealbuminSolid phase extractionChromatographyNanopartículesChemistryElutionSolid Phase Extraction010401 analytical chemistryOrganic ChemistryON-LINE SOLID-PHASE EXTRACTIONElectrophoresis CapillaryReproducibility of ResultsGeneral MedicineMONOLITHIC MICROCARTRIDGETRANSTHYRETIN0104 chemical sciencesEspectrometria de massesIsoelectric pointColloidal goldGOLD NANOPARTICLESEpoxy CompoundsMethacrylatesNanoparticlesGoldIon trapBiomarkers
researchProduct

Sudden death in adolescence caused by cardiac haemangioma

2009

Primary tumors of the heart in infants and children are rare. The types of heart tumors in pediatric age groups are generally different from those in adults. Cardiac myxoma is by far the most common tumor in adults, but in infants and adolescents the prevalent tumor of the heart is rhabdomyoma. Among benign cardiac tumors, cardiac hemangiomas are rare and often diagnosed post-mortem due to the lack of specific clinical symptoms and signs. We report a case of sudden death due to cardiac hemangioma in an apparently healthy 15-year-old adolescent. The autopsy revealed a cardiac hemangioma located at the apex of the heart; the histopathological examination showed the tumor was a mixed capillary…

MalePathologymedicine.medical_specialtyPrimary tumors of the heartAdolescentAutopsyRhabdomyomaSettore MED/08 - Anatomia PatologicaSudden death cardiac haemangiomaSudden deathPathology and Forensic MedicineHemangiomaHeart NeoplasmsDeath SuddenSettore MED/43 - Medicina LegalemedicineHumanscardiovascular diseasesHemangioma CapillaryForensic Pathologybusiness.industryMyocardiumCardiac hemangiomaMyxomaGeneral Medicinemedicine.diseasePrimary tumorcardiovascular systembusinessLaw
researchProduct

Optical coherence tomography angiography evaluation of peripapillary microvascular changes after rhegmatogenous retinal detachment repair

2021

PURPOSE To evaluate the radial peripapillary capillary plexus (RPCP) vessel density (VD) and the retinal nerve fiber layer (RNFL) thickness in eyes successfully treated with pars plana vitrectomy for primary rhegmatogenous retinal detachment. METHODS In this cross-sectional multicenter clinical study, eyes with a minimum 12-month follow-up were reexamined. The RPCP VD and RNFL thickness in the rhegmatogenous retinal detachment subfields of the affected eye (study group) were compared with the corresponding areas of the healthy fellow eyes (control group). RESULTS Fifty-three eyes were included in the study. A significantly lower RPCP VD and RNFL thickness were observed in those subfields af…

MaleRetinal Ganglion Cellsgenetic structuresComputed Tomography Angiographymedicine.medical_treatmentNerve fiber layerVisual AcuityVitrectomyEyeradial peripapillary capillary plexuschemistry.chemical_compoundNerve FibersVitrectomyTomographyRetinal detachment repairRetinal detachmentGeneral MedicineMiddle AgedAxial Length Eyemedicine.anatomical_structureFemaleTomography Optical CoherencePars planamedicine.medical_specialtyBiometryOptic DiskEndotamponaderetinal detachmentOCT-angiography; Radial peripapillary capillary plexus; Retinal detachment; Retinal nerve fiber layer; Aged; Axial Length Eye; Biometry; Cross-Sectional Studies; Endotamponade; Female; Humans; Male; Middle Aged; Nerve Fibers; Optic Disk; Retinal Detachment; Retinal Ganglion Cells; Retinal Vessels; Retrospective Studies; Visual Acuity; Computed Tomography Angiography; Tomography Optical Coherence; VitrectomyOphthalmologymedicineHumansAxial LengthAgedRetrospective StudiesRetinabusiness.industryradial peripapillary capillary plexus; OCT-angiography; retinal nerve fiber layer; retinal detachmentRetinal Vesselsretinal nerve fiber layerRetinalOptical coherence tomography angiographymedicine.diseaseeye diseasesOphthalmologyCross-Sectional StudieschemistryOptical Coherencesense organsOCT-angiographybusiness
researchProduct

Preliminary communication: imiquimod in mixed capillary/lymphatic malformation.

2008

:  The present authors reported a 14-year-old white boy who visited the present authors’ dermatology department in January 2004. Physical examination revealed multiple translucent and hemorrhagic vesicles and skin-colored nodules on the chin. The lesion had grown slowly in size over the previous 7 years. The objective of this study is to estimate the exact mechanism of action of topical imiquimod on mixed capillary/lymphatic malformation. After 4 weeks of therapy the lesions were less protuberant. At the follow-up examination after a further 2 months of therapy, there was partial clinical regression of the capillary component with a return to normal skin color. One month after termination o…

Malemedicine.medical_specialtyChinAdolescentPhysical examinationImiquimodDermatologyLesionAdjuvants ImmunologicmedicineSettore MED/35 - Malattie Cutanee E VenereeHumansLymphatic VesselsImiquimodLymphatic Abnormalitiesmedicine.diagnostic_testbusiness.industryDermatology departmentGeneral MedicineDermatologyChinSurgeryCapillariesLymphatic systemmedicine.anatomical_structureimiquimod mixed capillary/lymphatic malformationAminoquinolinesmedicine.symptomTopical imiquimodFacial NeoplasmsNormal skinbusinessHemangiomamedicine.drugDermatologic therapy
researchProduct