Search results for " Circuits"
showing 10 items of 187 documents
Automated Calculation Method to Determine the Output Power Based on the Frequency for Induction Heating IGBT Parallel Inverter
2007
The fact that some inverter topologies used in induction heating applications allow the soft switching working operation lets the progressive replacement of the MOSFET with the IGBT in high power inverters. This is due to two main reasons, the former is the IGBT reliability and the latter is the ratio defined as the price of the component per output power. In this article an automated method to determine the output power based on the frequency of an inverter build with different IGBT is described. To carry out this method is necessary to define the power cycle and to develop the calculation process which determines the energy losses in the working conditions of the resonant parallel inverte…
Soft switched interleaved boost converters used as high-power battery discharge regulator for space power systems
2004
In the following years the telecommunication satellites will have a much greater power demand than nowadays. One reason for this is that the geostationary orbit required by this kind of satellites is becoming too crowded. Probably power levels of l0 kW to l00 kW will be the standard and with life duration of 25 years. It is not possible to keep 0.5 kW modules with more than 100 in parallel and therefore higher power modules (5 kW) must be used. A higher bus voltage seems also necessary and keeping a safety limit of 150 V, any voltage below it and above 100 V could meet the needs. In this paper we will propose a topology that fits the application: two soft switched interleaved boost converte…
Finite Element Simulation of Multilayer Metal Cylinder Head Gaskets
2006
ABAQUS gasket elements are an efficient and flexible tool to study gasket applications. Nevertheless the usage of the ABAQUS gasket elements is not limited to gasket analysis, but it provides an effective improvement in structural analysis. The results point out that both the predicted contact pressure and the predicted stress distribution depend on the mesh topology. Several combinations of mesh dimension and topology are investigated. The purpose is the definition of a calculation methodology and the demonstration of the application potentiality. Complex models analysis highlights that the set methodology constitutes a very effective tool for the design and optimization of gasket, cylinde…
DC link voltage swinging and load current unbalance in fault tolerant VSI. overview and compensation strategies
2015
The topic of this paper is the discussion on the performance of a three-phase fault tolerant inverter with particular attention to the underrated aspect of current unbalances occurring due to the DC link voltage fluctuates after the inverter reconfiguration. Capacitor voltage unbalance affects not only the average output voltage of the inverter, but also its performance. In fact, the inverter performance depends on the fluctuating DC-link voltage components rather than on the average DC-link voltage. After a brief analysis of the voltage fluctuation phenomena resulting from fault tolerant configuration and their effect on load current unbalance, the Authors consider different compensating p…
Magnetic Tunnel Junction (MTJ) Sensors for Integrated Circuits (IC) Electric Current Measurement
2013
We report on MgO Magnetic Tunnel Junction (MTJ) devices focusing on their potential application in the measurement of electrical current at the integrated circuit level. Single devices and full bridges have been specifically developed for this purpose. A sort of different designs regarding their geometry arrangement as well as the number of constitutive elements have been tested. Experimental characterization has been performed and results including impedance and sensitivity measurements are given.
Phasor total unbalance power: Formulation and some properties
2007
Unbalance power has been used to quantify unbalance phenomenon effects in the electric power systems for a long time. Expressions of this power developed by some different theories only give the value of its module. Therefore, total unbalance power values in electric power systems cannot be obtained by the unbalance power values of each of their loads. For that, it is necessary to express the unbalance power as a complex number. In this paper the unbalance power is expressed in phasor notation and some of their properties are described, applied to electric systems with balanced voltages. Results are verified by simulation and also practical comparative experiences are realized in actual ins…
A suitable control technique for fault-tolerant converters in Distributed Generation
2011
The penetration of Distributed Generation (DG) in power systems is deeply changing the existing distribution networks which is becoming a very sophisticated and complex systems incorporating both active (generators) and passive systems (distribution systems, converters and loads). The necessary simplification can be obtained dealing with small networks, namely Micro-Grids, reproducing, in a smaller scale, the structure and the problems of large networks including production, transmission and distribution of the electrical energy. In order to achieve an adequate level of reliability, fault-tolerant operations of micro-grids become very important. This result can be achieved only using power …
Novel Fault-Tolerant Routing Technique for ZMesh Topology based Network-on-Chip Design
2020
This paper proposes a novel fault-tolerant routing technique for ZMesh topology based Network-on-Chip (NoC) design. The proposed algorithm caters the link faults and routes the data packets seamlessly to the destination. This algorithm has been compared with the existing techniques proposed for mesh topology counterparts. The experimentations have been carried out by increasing ZMesh network size and percentage of link faults. The results show that in the event of link failures the proposed algorithm routes the data from source to destination flawlessly.
Hardware and firmware developments for the upgrade of the ATLAS Level-1 Central Trigger Processor
2014
The Central Trigger Processor (CTP) is the final stage of the ATLAS first level trigger system which reduces the collision rate of 40 MHz to a Level-1 event rate of 100 kHz. An upgrade of the CTP is currently underway to significantly increase the number of trigger inputs and trigger combinations, allowing additional flexibility for the trigger menu. We present the hardware and FPGA firmware of the newly designed core module (CTPCORE+) module of the CTP, as well as results from a system used for early firmware and software prototyping based on commercial FPGA evaluation boards. First test result from the CTPCORE+ module will also be shown.
Human experts vs. machines in taxa recognition
2020
The step of expert taxa recognition currently slows down the response time of many bioassessments. Shifting to quicker and cheaper state-of-the-art machine learning approaches is still met with expert scepticism towards the ability and logic of machines. In our study, we investigate both the differences in accuracy and in the identification logic of taxonomic experts and machines. We propose a systematic approach utilizing deep Convolutional Neural Nets with the transfer learning paradigm and extensively evaluate it over a multi-pose taxonomic dataset with hierarchical labels specifically created for this comparison. We also study the prediction accuracy on different ranks of taxonomic hier…