Search results for " Computer-Assisted"
showing 10 items of 1033 documents
Volumetry of Ventilated Airspaces by 3He MRI
2001
To develop a validated post-processing routine for volumetry of the ventilated airspaces by 3He MRI.3Helium MRI and pulmonary function tests were performed in seven healthy volunteers. After segmentation of ventilated airspaces, their volumes were calculated. Functional residual capacity (FRC) was used as a reference. For comparison of absolute volumes, correction factors were evaluated.Mean lung volume (+/- standard deviation) calculated from 3He MRI was 4,082 +/- 908 mL and mean FRC was 3,696 +/- 1166 mL, with a mean difference of 386 mL (r = 0.88). After correction for the relative pulmonary air content (factor 0.82), posture (0.72), and the individual tidal volume, 3He MRI volume was 3,…
Three-dimensional (3D) versus two-dimensional (2D) laparoscopic adrenalectomy: A case-control study
2016
Abstract Introduction Laparoscopic adrenalectomy is today considered the gold standard of treatment for adrenal tumors. The development of high definition cameras does not eliminate the major limitation of two-dimensional (2D) laparoscopy: lack of depth perception and loss of spatial orientation. Tree-dimensional (3D) HD laparoscopy was developed as an alternative to conventional 2D laparoscopy. Methods We report our experience with use of 3D vision system for laparoscopic adrenalectomy. Between January 2009 and March 2015 we performed a total of 52 laparoscopic adrenalectomies. In this case-control study we considered 13 laparoscopic adrenalectomies performed with three-dimensional (3D) vi…
Effects of a 21 days space flight on the mechanical performance and the EMG power spectrum of the leg muscles
2002
Objective measurement of intraocular forward light scatter using Hartmann-Shack spot patterns from clinical aberrometers. Model-eye and human-eye stu…
2007
Purpose To apply software-based image-analysis tools to objectively determine intraocular scatter determined from clinically derived Hartmann-Shack patterns. Setting Aston Academy of Life Sciences, Aston University, Birmingham, United Kingdom, and Department of Optics, University of Valencia, Valencia, Spain. Methods Purpose-designed image-analysis software was used to quantify scatter from centroid patterns obtained using a clinical Hartmann-Shack analyzer (WASCA, Zeiss/Meditec). Three scatter values, as the maximum standard deviation within a lenslet for all lenslets in the pattern, were obtained in 6 model eyes and 10 human eyes. In the model-eye sample, patterns were obtained in 4 sessi…
(De-)Accentuation and the Processing of Information Status: Evidence from Event-Related Brain Potentials
2012
The paper reports on a perception experiment in German that investigated the neuro-cognitive processing of information structural concepts and their prosodic marking using event-related brain potentials (ERPs). Experimental conditions controlled the information status (given vs. new) of referring and non-referring target expressions (nouns vs. adjectives) and were elicited via context sentences, which did not – unlike most previous ERP studies in the field – trigger an explicit focus expectation. Target utterances displayed prosodic realizations of the critical words which differed in accent position and accent type. Electrophysiological results showed an effect of information status, maxi…
High-Speed Imaging Analysis of Register Transitions in Classically and Jazz-Trained Male Voices
2014
<b><i>Background:</i></b> Little data are available concerning register functions in different styles of singing such as classically or jazz-trained voices. Differences between registers seem to be much more audible in jazz singing than classical singing, and so we hypothesized that classically trained singers exhibit a smoother register transition, stemming from more regular vocal fold oscillation patterns. <b><i>Methods:</i></b> High-speed digital imaging (HSDI) was used for 19 male singers (10 jazz-trained singers, 9 classically trained) who performed a glissando from modal to falsetto register across the register transition. Vocal fold osc…
Word order and Broca’s region: Evidence for a supra-syntactic perspective
2008
It has often been suggested that the role of Broca's region in sentence comprehension can be explained with reference to general cognitive mechanisms (e.g. working memory, cognitive control). However, the (language-related) basis for such proposals is often restricted to findings on English. Here, we argue that an extension of the database to other languages can shed new light on the types of mechanisms that an adequate account of Broca's region should be equipped to deal with. This becomes most readily apparent in the domain of word order variations, which we examined in German verb-final sentences using event-related fMRI. Our results showed that activation in the pars opercularis--a core…
Multislice multiecho T2* cardiovascular magnetic resonance for detection of the heterogeneous distribution of myocardial iron overload.
2006
Purpose To assess the tissue iron concentration of the left ventricle (LV) using a multislice, multiecho T2* MR technique and a segmental analysis. Materials and Methods T2* multiecho MRI was performed in 53 thalassemia major patients. Three short-axis views of the LV were obtained and analyzed with custom-written software. The myocardium was automatically segmented into 12 segments. The T2* value on each segment as well as the global T2* value were calculated. Cine dynamic images were also obtained to evaluate biventricular function parameters by quantitative analysis. Results For the T2* global value, the coefficient of variation (CoV) for intra-/interobserver and interstudy reproducibili…
Muscle kinematics during isometric contraction: Development of phase contrast and spin tag techniques to study healthy and atrophied muscles
2004
Purpose To develop and compare phase-contrast (PC) and spin-tag (ST) MR imaging techniques for accurate quantification of velocity and displacement distribution in the muscle tendon complex of the lower leg during isometric contractions under in vivo conditions, in healthy subjects and subjects with atrophy. Materials and Methods Techniques were developed to acquire PC and ST dynamic images, gated to the force exerted by a subject during isometric contraction. Algorithms were optimized for correction of phase shading errors. Flow velocity quantification was validated in phantoms and ex vivo rabbit muscles. Trajectories of pixels calculated from PC images were compared with those in ST image…
Usefulness of quantitative peritumoural perfusion and proton spectroscopic magnetic resonance imaging evaluation in differentiating brain gliomas fro…
2016
Objectives The purpose of our study was to evaluate whether peritumoural perfusion weighted and proton spectroscopic magnetic resonance imaging can be used in differentiating between primary gliomas and solitary metastases. Methods Ten low-grade gliomas, eight high-grade gliomas and 10 metastases were prospectively evaluated with magnetic resonance imaging, dynamic susceptibility contrast enhanced perfusion imaging and single-voxel proton magnetic resonance spectroscopy before surgical resection or stereotactic biopsy. Maximal relative cerebral blood volume values were calculated drawing three regions of interest of 2 cm2 in the non-enhancing peritumoural areas. Maximal relative cerebral bl…