Lead Reconstruction Using Artificial Neural Networks for Ambulatory ECG Acquisition
2021
One of the most powerful techniques to diagnose cardiovascular diseases is to analyze the electrocardiogram (ECG). To increase diagnostic sensitivity, the ECG might need to be acquired using an ambulatory system, as symptoms may occur during a patient’s daily life. In this paper, we propose using an ambulatory ECG (aECG) recording device with a low number of leads and then estimating the views that would have been obtained with a standard ECG location, reconstructing the complete Standard 12-Lead System, the most widely used system for diagnosis by cardiologists. Four approaches have been explored, including Linear Regression with ECG segmentation and Artificial Neural Networks (ANN). The b…
Morse Description and Geometric Encoding of Digital Elevation Maps
2004
Two complementary geometric structures for the topographic representation of an image are developed in this work. The first one computes a description of the Morse-topological structure of the image, while the second one computes a simplified version of its drainage structure. The topographic significance of the Morse and drainage structures of digital elevation maps (DEMs) suggests that they can been used as the basis of an efficient encoding scheme. As an application, we combine this geometric representation with an interpolation algorithm and lossless data compression schemes to develop a compression scheme for DEMs. This algorithm achieves high compression while controlling the maximum …
Automated detection of patient movement during a CBCT scan based on the projection data.
2015
Objectives To develop an automated procedure to detect patient motion on the projection images acquired during a cone beam computed tomography (CBCT) scan and to evaluate the method's feasibility on small real-world CBCT images in relation to visual assessment. Methods Based on optical flow theory, software was developed using the sequence of the projection images of a CBCT machine for automated detection of patient motion. Averaged acceleration vectors were used as measurement data and compared with visual assessment of the projection images displayed as video. Seventy-nine CBCT data sets (small field-of-view: 40 mm) from our patient database were selected in a sequential fashion and evalu…
Dental CBCT equipment and performance issues
2012
Dental cone beam computed tomography (CBCT), also known as digital volumetric tomography was developed in the late 1990s and is now increasingly available in clinical practice. It can provide high resolution cross-sectional images of teeth and the maxillofacial region with applications in all branches of dentistry. As a new imaging modality, there were no established suspension levels at a European level. A literature review, encompassing scientific, professional publications and existing national guidelines was performed in an attempt to develop a set of suspension levels for dental CBCT, using additional expert opinion from the members of the European Academy of dento-maxillo-facial radio…
Contrast perception in digitized panoramic radiographs compared with their film-based origin
2002
Abstract Objectives. We sought to compare the visual image quality of film-based and digitized panoramic radiographs through use of a hole-containing test wedge. Study Design. An aluminum wedge containing 100 cells, of which 90 were given shallow holes, was exposed in the film-based Orthophos CD panoramic unit. Two radiographs subjectively exhibiting optimum contrast were selected. Films were digitized with a charge-coupled device flatbed scanner at 300 dpi. Films and digitized images were rated cellwise by 2 similar groups of 50 observers each with respect to spot perception. Results. The mean sensitivity was 0.26 ± 0.09 for film and 0.20 ± 0.07 for digitized images (P =.000), with a prono…
Mammographic images segmentation based on chaotic map clustering algorithm
2013
Background: This work investigates the applicability of a novel clustering approach to the segmentation of mammographic digital images. The chaotic map clustering algorithm is used to group together similar subsets of image pixels resulting in a medically meaningful partition of the mammography. Methods: The image is divided into pixels subsets characterized by a set of conveniently chosen features and each of the corresponding points in the feature space is associated to a map. A mutual coupling strength between the maps depending on the associated distance between feature space points is subsequently introduced. On the system of maps, the simulated evolution through chaotic dynamics leads…
Granulometric analysis of corneal endothelium specular images by using a germ–grain model
2007
Specular microscopy is widely used to study the human corneal endothelium status in vivo. In this paper, the corneal endothelium is represented as a binary image composed of the cell inscribed circles. The granulometric distribution function of the complement of this image is used as a functional descriptor, which provides information about the shape, size and spatial arrangement of cells. Experimental evaluation using bootstrap techniques shows its ability to discriminate between controls and pathological cases. It represents a reliable and graphical alternative to the classical indices (cell density, hexagonality and coefficient of variation of cell areas), which behave poorly when detect…
Prevalence of anatomical variants and coronary anomalies in 543 consecutive patients studied with 64-slice CT coronary angiography
2008
The aim of our study was to assess the prevalence of variants and anomalies of the coronary artery tree in patients who underwent 64-slice computed tomography coronary angiography (CT-CA) for suspected or known coronary artery disease. A total of 543 patients (389 male, mean age 60.5 +/- 10.9) were reviewed for coronary artery variants and anomalies including post-processing tools. The majority of segments were identified according to the American Heart Association scheme. The coronary dominance pattern results were: right, 86.6%; left, 9.2%; balanced, 4.2%. The left main coronary artery had a mean length of 112 +/- 55 mm. The intermediate branch was present in the 21.9%. A variable number …
Rationale, design and methods of CTCA-PRORECAD (Computed Tomography Coronary Angiography Prognostic Registry for Coronary Artery Disease): a multicen…
2013
PURPOSE: This study was done to assess the prognostic value of computed tomography coronary angiography (CTCA) in a large multicentre population of patients with suspected coronary artery disease (CAD) and, in particular, its incremental value compared with traditional methods for risk stratification. MATERIALS AND METHODS: This is a retrospective observational study that began in January 2003 conducted on patients with suspected CAD assessed with CTCA on the basis of symptoms (chest pain, dyspnoea) and/or abnormal or equivocal stress test and/or a high cardiovascular risk profile. The participating centres will provide data obtained with CTCA performed with 16-slice or higher equipment. Ex…
Prognostic outcome of routine clinical noninvasive Multidetector row Computed Tomography Coronary Angiography in Patients with suspected coronary art…
2011
The aim of the study was to assess the prognostic value of multidetector-row CT coronary angiography (MDCT-CA) in patients with suspected coronary artery disease (CAD) in a routine clinical context.A total of 125 patients (82 men, age 57.4±10.3 years) with suspected CAD underwent MDCT-CA. All patients were assessed for cardiovascular risk factors, symptoms and coronary calcium score. A 2-year follow-up study for the occurrence of major adverse cardiac events was performed.According to the Morise pretest score, 76 patients (60.8%) were at intermediate risk. Patients with suspected CAD presented the following prognostic outcome (p0.0001): in 41 patients with normal coronary arteries at MDCT-C…