Search results for " Computer-Assisted"
showing 10 items of 1033 documents
Wavelength-compensated time-sequential multiplexed color joint transform correlator
2010
We report a wavelength-compensated three-channel (RGB) joint transform correlator (JTC) for color pattern recognition using a ferroelectric liquid-crystal spatial light modulator (SLM) operating in binary pure phase modulation. We apply a previously reported time-multiplexing technique useful in creating wavelength-compensated diffraction patterns, based on the synchronization of properly scaled diffraction masks with the input wavelength selection obtained by applying a rotating RGB color-filter wheel to an Ar-Kr laser. The application of this technique to a JTC architecture permits real-time color object detection. In order to achieve a high light efficiency for the correlation process, w…
Fast and robust phase-shift estimation in two-dimensional structured illumination microscopy.
2019
A method of determining unknown phase-shifts between elementary images in two-dimensional Structured Illumination Microscopy (2D-SIM) is presented. The proposed method is based on the comparison of the peak intensity of spectral components. These components correspond to the inherent structured illumination spectral content and the residual compo- nent that appears from wrongly estimated phase-shifts. The estimation of the phase-shifts is carried out by finding the absolute maximum of a function defined as the normalized peak intensity difference in the Fourier domain. This task is performed by an optimization method providing a fast estimation of the phase-shift. The algorithm stability an…
Physics, Techniques and Review of Neuroradiological Applications of Diffusion Kurtosis Imaging (DKI)
2016
In recent years many papers about diagnostic applications of diffusion tensor imaging (DTI) have been published. This is because DTI allows to evaluate in vivo and in a non-invasive way the process of diffusion of water molecules in biological tissues. However, the simplified description of the diffusion process assumed in DTI does not permit to completely map the complex underlying cellular components and structures, which hinder and restrict the diffusion of water molecules. These limitations can be partially overcome by means of diffusion kurtosis imaging (DKI). The aim of this paper is the description of the theory of DKI, a new topic of growing interest in radiology. DKI is a higher or…
Time-resolved fluorescence and fourier transform infrared spectroscopic investigations of lateral packing defects and superlattice domains in composi…
2003
Time-resolved fluorescence and Fourier transform infrared spectroscopies were used to investigate the lateral organization of lipids in compositionally uniform and fully equilibrated 1-palmitoyl-2-oleoyl-phosphatidylcholine/cholesterol (POPC/CHOL) liposomes prepared by a recently devised low-temperature trapping method. Independent fluorescence decay lifetime and rotational dynamics parameters of diphenylhexatriene (DPH) chain-labeled phosphatidylcholine (DPH-PC) in these liposomes were recovered from the time-resolved fluorescence measurements as a function of cholesterol molar fraction (X(CHOL)) at 23 degrees C. The results indicate significantly greater lifetime heterogeneity, shorter av…
Automated detection and localization system of myocardial infarction in single-beat ECG using Dual-Q TQWT and wavelet packet tensor decomposition.
2019
Abstract Background and objective It is challenging to conduct real-time identification of myocardial infarction (MI) due to artifact corruption and high dimensionality of multi-lead electrocardiogram (ECG). In the present study, we proposed an automated single-beat MI detection and localization system using dual-Q tunable Q-factor wavelet transformation (Dual-Q TQWT) denoising algorithm. Methods After denoising and segmentation of ECG, a fourth-order wavelet tensor (leads × subbands × samples × beats) was constructed based on the discrete wavelet packet transform (DWPT), to represent the features considering the information of inter-beat, intra-beat, inter-frequency, and inter-lead. To red…
Drug delivery from the oral cavity: focus on a novel mechatronic delivery device
2007
Dental drug delivery systems have been used for a long time, in particular for the local therapy of diseases affecting the oral cavity. Research today concentrates on the design of formulations to increase their retention time. Even today, however, prosthetic devices incorporating drug delivery are rarely used. Mainly, they are focused on prophylaxis and the release of antibacterial agents. However, as buccal delivery, because of its undeniable advantages, has become popular for systemic drug delivery, and prolonged well-controlled release has been identified as beneficial, especially for chronic diseases, a new class of delivery systems is evolving: highly miniaturized computerized deliver…
Early alterations of the behavioural structure of mice affected by Duchenne muscular dystrophy and tested in open-field
2020
Present study has been carried out to assess whether early alterations of the behavioural structure may be detected in mice affected by Duchenne muscular dystrophy (DMD). To this purpose, both quantitative and T-pattern analysis (TPA) were used to analyse the behaviour of two groups of male, two months old mice, 18 MDX and 18 normal as control, tested in an open-field apparatus. T-pattern analysis is a multivariate technique able to reveal hidden structural features of behaviour and, in particular, its temporal characteristics. As to quantitative analyses, mean durations evidenced a significant increase of Walking, Modified Climbing and Rearing and a significant reduction of Immobile-Sniffi…
E-learning in radiology: an Italian multicentre experience.
2012
Objective: The aim of this study was to design, deliver and evaluate an e-learning teaching programme for post-graduate radiodiagnostics training that would involve various post-graduate schools throughout Italy. Materials and methods: All of the Directors of Italian post-graduate schools of radiodiagnostics were sent an e-mail on 27 September 2010 informing them of our willingness to set up an e-learning project for the academic year 2010-2011 in the form of single-subject teaching seminars. The proposed subjects were the semeiotics of the various organs and apparatuses in the context of "Urgent/Emergency Pathology". After having received registrations, a calendar of lessons was planned to…
A concept for a magnetic particle imaging scanner with Halbach arrays
2020
Magnetic particle imaging (MPI) is a new medical imaging technique visualizing the concentration distribution of superparamagnetic nanoparticles used as tracer material. MPI is not yet in clinical routine, since one of the challenges is the upscaling of scanners. Typically, the magnetic fields of MPI scanners are generated electromagnetically, resulting in an immense power consumption but providing high flexibility in terms of adjusting the field strengths and very fast image acquisition rates. Permanent magnets provide high flux densities and do not need any power supply. However, the flux density is not adjustable, and a mechanical movement is slow compared to electromagnetically varying …
Compensation of missing wedge effects with sequential statistical reconstruction in electron tomography.
2014
Electron tomography (ET) of biological samples is used to study the organization and the structure of the whole cell and subcellular complexes in great detail. However, projections cannot be acquired over full tilt angle range with biological samples in electron microscopy. ET image reconstruction can be considered an ill-posed problem because of this missing information. This results in artifacts, seen as the loss of three-dimensional (3D) resolution in the reconstructed images. The goal of this study was to achieve isotropic resolution with a statistical reconstruction method, sequential maximum a posteriori expectation maximization (sMAP-EM), using no prior morphological knowledge about …