0.48Tb/s (12x40Gb/s) WDM transmission and high-quality thermo-optic switching in dielectric loaded plasmonics
2012
We demonstrate Wavelength Division Multiplexed (WDM)-enabled transmission of 480Gb/s aggregate data traffic (12x40Gb/s) as well as high-quality 1x2 thermo-optic tuning in Dielectric-Loaded Surface Plasmon Polariton Waveguides (DLSPPWs). The WDM transmission characteristics have been verified through BER measurements by exploiting the heterointegration of a 60 mu m-long straight DLSPPW on a Silicon-on-Insulator waveguide platform, showing error-free performance for six out of the twelve channels. High-quality thermo-optic tuning has been achieved by utilizing Cycloaliphatic-Acrylate-Polymer as an efficient thermo-optic polymer loading employed in a dual-resonator DLSPPW switching structure, …
Subtractive imaging in confocal scanning microscopy using a CCD camera as a detector
2012
[EN] We report a scheme for the detector system of confocal microscopes in which the pinhole and a large-area detector are substituted by a CCD camera. The numerical integration of the intensities acquired by the active pixels emulates the signal passing through the pinhole. We demonstrate the imaging capability and the optical sectioning of the system. Subtractive-imaging confocal microscopy can be implemented in a simple manner, providing superresolution and improving optical sectioning. (C) 2012 Optical Society of America
A monte carlo study of dose rate distribution around the specially asymmetric CSM3-a 137Cs source.
2001
The CSM3 137Cs type stainless-steel encapsulated source is widely used in manually afterloaded low dose rate brachytherapy. A specially asymmetric source, CSM3-a, has been designed by CIS Bio International (France) substituting the eyelet side seed with an inactive material in the CSM3 source. This modification has been done in order to allow a uniform dose level over the upper vaginal surface when this `linear' source is inserted at the top of the dome vaginal applicators. In this study the Monte Carlo GEANT3 simulation code, incorporating the source geometry in detail, was used to investigate the dosimetric characteristics of this special CSM3-a 137Cs brachytherapy source. The absolute do…
Femtosecond digital lensless holographic microscopy to image biological samples
2013
The use of femtosecond laser radiation in digital lensless holographic microscopy (DLHM) to image biological samples is presented. A mode-locked Ti:Sa laser that emits ultrashort pulses of 12 fs intensity FWHM, with 800 nm mean wavelength, at 75 MHz repetition rate is used as a light source. For comparison purposes, the light from a light-emitting diode is also used. A section of the head of a drosophila melanogaster fly is studied with both light sources. The experimental results show very different effects of the pinhole size on the spatial resolution with DLHM. Unaware phenomena on the field of the DLHM are analyzed.
Transverse chemical interface detection with coherent anti-Stokes Raman scattering microscopy
2011
International audience; Transverse "chemical" interfaces are revealed with a conventional two beam narrowband coherent anti-Stokes Raman scattering microscopy setup in a collinear configuration. The exciting "pump" and "Stokes" beams are focused on the sample in two opposite directions. The subtraction of the two generated anti-Stokes signals gives rise to a signal that is directly proportional to the pure Raman spectrum of the resonant medium. This property is used to highlight an interface between glass and N,N-dimethylformamide (DMF) and recover the pure Raman spectrum of DMF around its 1408 cm−1 vibrational band.
Simulated one-pass list-mode: an approach to on-the-fly system matrix calculation.
2013
In the development of prototype systems for positron emission tomography a valid and robust image reconstruction algorithm is required. However, prototypes often employ novel detector and system geometries which may change rapidly under optimization. In addition, developing systems generally produce highly granular, or possibly continuous detection domains which require some level of on-the-fly calculation for retention of measurement precision. In this investigation a new method of on-the-fly system matrix calculation is proposed that provides advantages in application to such list-mode systems in terms of flexibility in system modeling. The new method is easily adaptable to complicated sy…
Estimation of the elastic parameters of human liver biomechanical models by means of medical images and evolutionary computation.
2013
This paper presents a method to computationally estimate the elastic parameters of two biomechanical models proposed for the human liver. The method is aimed at avoiding the invasive measurement of its mechanical response. The chosen models are a second order Mooney–Rivlin model and an Ogden model. A novel error function, the geometric similarity function (GSF), is formulated using similarity coefficients widely applied in the field of medical imaging (Jaccard coefficient and Hausdorff coefficient). This function is used to compare two 3D images. One of them corresponds to a reference deformation carried out over a finite element (FE) mesh of a human liver from a computer tomography image, …
Advantages of fitting contrast curves using logistic function: a technical note.
2013
Objective The aim of this article is to demonstrate how the contrast properties of an imaging system can be ideally fitted with the use of stripe patterns and the logistic function. Study Design Stripe patterns with defined amounts of line pairs (lp/mm) per mm (10-20 lp/mm) were recorded with the use of digital photostimulable storage phosphor. Scan data and normalized image data were analyzed with the use of ImageJ and MatLab to calculate different contrast curves. Results For original scan data, the goodness of fit was 0.0000019 (sum of squared error [SSE]). The R-square was 0.9998. For normalized data the goodness of fit was 0.0007 (SSE) and the R-square 0.998. An amount of 50% contrast …
New, fast, and accurate procedure to calibrate a 2-dimensional digital measurement method.
2005
Traditionally, dental casts have been measured by hand, with conventional calipers. Today, several digital methods are available for automatically measuring tooth size, but their accuracy depends on proper calibration. The purpose of this article is to introduce a fast and accurate procedure to calibrate a previously introduced 2-dimensional computerized system of measuring mesiodistal tooth size and calculating overall and anterior Bolton ratios. In this calibration method, the cast is digitized while sitting on a sheet of graph paper. The magnification of the paper in 2 axes can be easily calculated and hence the magnification of the dental cast digital image.
The decision support system for telemedicine based on multiple expertise
1998
This paper discusses the application of artificial intelligence in telemedicine and some of our research results in this area. The main goal of our research is to develop methods and systems to collect, analyse, distribute and use medical diagnostics knowledge from multiple knowledge sources and areas of expertise. Use of modern communication tools enable a physician to collect and analyse information obtained from experts worldwide with the help of a decision support medical system. In this paper we discuss a multilevel representation and processing of medical data using a system which evaluates and exploits knowledge about the behaviour of statistical diagnostics methods. The presented te…