Search results for " Detectors"

showing 10 items of 2027 documents

Planar Technology for NDT-Ge X-Ray Microcalorimeters: Absorber Fabrication

2009

We have investigated the electroplating process to deposit thick uniform films of tin on a Ge wafer coated with Spin‐On Glass, in order to fabricate the absorbers for Ge microcalorimeter arrays. Here we discuss some technological details and propose two alternative metal bilayer to be used as seed for the electroplating.

Materials scienceFabricationX-ray detectors planar technologybusiness.industryBilayerAnalytical chemistrychemistry.chemical_elementSettore ING-INF/01 - ElettronicaIon implantationPlanarSettore FIS/05 - Astronomia E AstrofisicachemistryNondestructive testingOptoelectronicsWaferTinbusinessElectroplating
researchProduct

Polarized neutron reflectivity from monolayers of self-assembled magnetic nanoparticles

2015

We prepared monolayers of iron oxide nanoparticles via self-assembly on a bare silicon wafer and on a vanadium film sputter deposited onto a plane sapphire substrate. The magnetic configuration of nanoparticles in such a dense assembly was investigated by polarized neutron reflectivity. A theoretical model fit shows that the magnetic moments of nanoparticles form quasi domain-like configurations at remanence. This is attributed to the dipolar coupling amongst the nanoparticles.

Materials scienceMagnetic momentPhysics::Instrumentation and DetectorsPhysics::OpticsNanoparticleCondensed Matter PhysicsMolecular physicsCondensed Matter::Materials ScienceCrystallographychemistry.chemical_compoundchemistryRemanenceMonolayerMagnetic nanoparticlesGeneral Materials ScienceWaferIron oxide nanoparticlesMagnetic dipole–dipole interactionJournal of Physics: Condensed Matter
researchProduct

Electrogeneration of Diiodoaurate in Dimethylsulfoxide on Gold Substrate and Localized Patterning

2016

International audience; A localized etching of gold surface by scanning electrochemical microscope technique is presented where a dimethylsulfoxide-based electrolyte charged with iodine is used. The electrogenerated triiodide ion at the platinum ultramicroelectrode tip (feedback mode) acts as an oxidant for gold surface. The effects of electrode diameter and the bias time have been investigated. The approach curve method was used to hold the electrode tip close to the gold surface. A scanning electron microscope is used to observe the etched gold surfaces where disk-shaped dots are generated. The diameter of these holes depends directly on the Pt electrode diameter and the bias time.

Materials scienceMicroscopeutramicroelectrodePhysics::Instrumentation and DetectorsScanning electron microscope020209 energyAnalytical chemistrychemistry.chemical_elementUltramicroelectrode02 engineering and technologyDFT[ CHIM ] Chemical Scienceslaw.invention[SPI.MAT]Engineering Sciences [physics]/MaterialsScanning electrochemical microscopyEtching (microfabrication)law0202 electrical engineering electronic engineering information engineeringElectrochemistry[CHIM]Chemical Sciencessilver[SPI.NANO]Engineering Sciences [physics]/Micro and nanotechnologies/Microelectronicsionic liquid[SPI.ACOU]Engineering Sciences [physics]/Acoustics [physics.class-ph]electron-beam lithographyself-assembled monolayersscanning electrochemical microscopyiodine-iodidegold etchingEQCMchemistryElectrodebis(trifluoromethanesulfonyl)imidefilmsfeedback modePlatinumSECMElectron-beam lithographydissolution kinetics
researchProduct

Wide range local resistance imaging on fragile materials by conducting probe atomic force microscopy in intermittent contact mode

2016

International audience; An imaging technique associating a slowly intermittent contact mode of atomic force microscopy (AFM) with a home-made multi-purpose resistance sensing device is presented. It aims at extending the widespread resistance measurements classically operated in contact mode AFM to broaden their application fields to soft materials (molecular electronics, biology) and fragile or weakly anchored nano-objects, for which nanoscale electrical characterization is highly demanded and often proves to be a challenging task in contact mode. Compared with the state of the art concerning less aggressive solutions for AFM electrical imaging, our technique brings a significantly wider r…

Materials scienceNanostructurePhysics and Astronomy (miscellaneous)optimisationNanotechnology02 engineering and technologyPhotovoltaic effectCarbon nanotube010402 general chemistry7. Clean energy01 natural scienceselectric resistance measurementlaw.inventioninfrared detectorslawMicroscopyThin filmNanoscopic scalethin film sensorsatomic force microscopycarbon nanotubesMolecular electronicsself-assembly[CHIM.MATE]Chemical Sciences/Material chemistry021001 nanoscience & nanotechnology0104 chemical sciencesCharacterization (materials science)monolayersphotodetectors0210 nano-technology
researchProduct

A Design of Scintillator Tiles Read Out by Surface-Mounted SiPMs for a Future Hadron Calorimeter

2015

Precision calorimetry using highly granular sampling calorimeters is being developed based on the particle flow concept within the CALICE collaboration. One design option of a hadron calorimeter is based on silicon photomultipliers (SiPMs) to detect photons generated in plastic scintillator tiles. Driven by the need of automated mass assembly of around ten million channels stringently required by the high granularity, we developed a design of scintillator tiles directly coupled with surface-mounted SiPMs. A cavity is created in the center of the bottom surface of each tile to provide enough room for the whole SiPM package and to improve collection of the light produced by incident particles…

Materials sciencePhotonPhysics - Instrumentation and Detectorsbusiness.industryDynamic rangePhysics::Instrumentation and DetectorsFOS: Physical sciencesCosmic rayInstrumentation and Detectors (physics.ins-det)ScintillatorOpticsSilicon photomultiplierSampling (signal processing)visual_artvisual_art.visual_art_mediumTilePhotonicsDetectors and Experimental Techniquesbusinessphysics.ins-det
researchProduct

SiPMs coated with TPB: coating protocol and characterization for NEXT

2012

[EN] Silicon photomultipliers (SiPM) are the photon detectors chosen for the tracking readout in NEXT, a neutrinoless \bb decay experiment which uses a high pressure gaseous xenon time projection chamber (TPC). The reconstruction of event track and topology in this gaseous detector is a key handle for background rejection. Among the commercially available sensors that can be used for tracking, SiPMs offer important advantages, mainly high gain, ruggedness, cost-effectiveness and radio-purity. Their main drawback, however, is their non sensitivity in the emission spectrum of the xenon scintillation (peak at 175 nm). This is overcome by coating these sensors with the organic wavelength shifte…

Materials sciencePhysics - Instrumentation and DetectorsFOS: Physical scienceschemistry.chemical_elementengineering.materialWavelength shifterTracking (particle physics)7. Clean energy01 natural sciencesHigh Energy Physics - ExperimentTECNOLOGIA ELECTRONICAHigh Energy Physics - Experiment (hep-ex)XenonSilicon photomultiplierCoating0103 physical sciencesSensitivity (control systems)Visible and IR photons (solid-state)010306 general physicsInstrumentationPhoton detectors for UVMathematical PhysicsScintillationTime projection chamber010308 nuclear & particles physicsbusiness.industryTime projection Chambers (TPC)FísicaDetectorsInstrumentation and Detectors (physics.ins-det)Gas detectorsScintillators scintillation and light emission processes (solid gas and liquid scintillators)Detectors de gasoschemistryParticle tracking detectors (Solid-state detectors)engineeringOptoelectronicsbusiness
researchProduct

Extending the applicability of an open-ring trap to perform experiments with a single laser-cooled ion.

2015

An open-ring ion trap, also referred to as transparent trap was initially built up to perform $\beta$-$\nu$ correlation experiments with radioactive ions. This trap geometry is also well suited to perform experiments with laser-cooled ions, serving for the development of a new type of Penning trap, in the framework of the project TRAPSENSOR at the University of Granada. The goal of this project is to use a single $^{40}$Ca$^+$ ion as detector for single-ion mass spectrometry. Within this project and without any modification to the initial electrode configuration, it was possible to perform Doppler cooling on $^{40}$Ca$^+$ ions, starting from large clouds and reaching single ion sensitivity.…

Materials sciencePhysics - Instrumentation and DetectorsIon beam[PHYS.PHYS.PHYS-ATOM-PH]Physics [physics]/Physics [physics]/Atomic Physics [physics.atom-ph]010308 nuclear & particles physicsAtomic Physics (physics.atom-ph)FOS: Physical sciencesInstrumentation and Detectors (physics.ins-det)Penning trapMass spectrometry01 natural sciencesIonPhysics - Atomic PhysicsTrap (computing)Physics::Plasma PhysicsLaser cooling0103 physical sciencesIon trapPhysics::Atomic PhysicsAtomic physicsNuclear Experiment (nucl-ex)010306 general physicsInstrumentationNuclear ExperimentDoppler coolingThe Review of scientific instruments
researchProduct

Limits on the release of Rb isotopes from a zeolite based 83mKr calibration source for the XENON project

2011

The isomer 83mKr with its half-life of 1.83 h is an ideal calibration source for a liquid noble gas dark matter experiment like the XENON project. However, the risk of contamination of the detector with traces of the much longer lived mother isotop 83Rb (86.2 d half-life) has to be ruled out. In this work the release of 83Rb atoms from a 1.8 MBq 83Rb source embedded in zeolite beads has been investigated. To do so, a cryogenic trap has been connected to the source for about 10 days, after which it was removed and probed for the strongest 83Rb gamma-rays with an ultra-sensitive Germanium detector. No signal has been found. The corresponding upper limit on the released 83Rb activity means tha…

Materials sciencePhysics - Instrumentation and DetectorsIsotope530 Physics3105 InstrumentationDark matterDetectorRadiochemistryCyclotronchemistry.chemical_elementNoble gasFOS: Physical sciences10192 Physics InstituteInstrumentation and Detectors (physics.ins-det)Semiconductor detectorlaw.inventionGenerator (circuit theory)Xenonchemistrylaw2610 Mathematical PhysicsAstrophysics - Instrumentation and Methods for AstrophysicsInstrumentationInstrumentation and Methods for Astrophysics (astro-ph.IM)Mathematical Physics
researchProduct

Diamond magnetometer enhanced by ferrite flux concentrators

2020

Magnetometers based on nitrogen-vacancy (NV) centers in diamond are promising room-temperature, solid-state sensors. However, their reported sensitivity to magnetic fields at low frequencies (<1 kHz) is presently >10 pT s^{1/2}, precluding potential applications in medical imaging, geoscience, and navigation. Here we show that high-permeability magnetic flux concentrators, which collect magnetic flux from a larger area and concentrate it into the diamond sensor, can be used to improve the sensitivity of diamond magnetometers. By inserting an NV-doped diamond membrane between two ferrite cones in a bowtie configuration, we realize a ~250-fold increase of the magnetic field amplitude wi…

Materials sciencePhysics - Instrumentation and DetectorsMagnetometerFOS: Physical sciences02 engineering and technologyApplied Physics (physics.app-ph)engineering.material01 natural sciencesArticlelaw.inventionlaw0103 physical sciencesThermalMesoscale and Nanoscale Physics (cond-mat.mes-hall)Laser power scaling010306 general physicsCondensed Matter - Mesoscale and Nanoscale Physicsbusiness.industryMicrowave powerDiamondInstrumentation and Detectors (physics.ins-det)Physics - Applied Physics021001 nanoscience & nanotechnologyMagnetic fluxMagnetic fieldengineeringFerrite (magnet)Optoelectronics0210 nano-technologybusinessOptics (physics.optics)Physics - Optics
researchProduct

Noncovalent force spectroscopy using wide-field optical and diamond-based magnetic imaging

2019

A realization of the force-induced remnant magnetization spectroscopy (FIRMS) technique of specific biomolecular binding is presented where detection is accomplished with wide-field optical and diamond-based magnetometry using an ensemble of nitrogen-vacancy (NV) color centers. The technique may be adapted for massively parallel screening of arrays of nanoscale samples.

Materials sciencePhysics - Instrumentation and DetectorsMagnetometerFOS: Physical sciencesGeneral Physics and AstronomyApplied Physics (physics.app-ph)02 engineering and technologyengineering.material01 natural scienceslaw.inventionMagnetizationlaw0103 physical sciencesPhysics - Biological PhysicsSpectroscopyMassively parallelNanoscopic scale010302 applied physicsQuantum Physicsbusiness.industryForce spectroscopyDiamondInstrumentation and Detectors (physics.ins-det)Physics - Applied Physics021001 nanoscience & nanotechnology3. Good healthBiological Physics (physics.bio-ph)engineeringOptoelectronicsQuantum Physics (quant-ph)0210 nano-technologybusinessRealization (systems)
researchProduct