Static meters for the reactive energy in the presence of harmonics: an experimental metrological characterization

2009

Electricity metering plays a crucial role for all the commercial transactions on the energy market. Thus, an accurate evaluation of the performance of the electricity metering equipment is required not only in the reference operating conditions but also in the presence of disturbances affecting the power systems. As regards this matter, this paper analyzes the main aspects related to the metrological characterization of the static meters for the reactive energy in the presence of harmonic distortion. Attention is focused not only to the meters covered by the current standards but also to the meters of better accuracy and to the reference standard meters. The analysis is supported by several…

EngineeringTotal harmonic distortionbusiness.industryComputingMethodologies_MISCELLANEOUSElectrical engineeringenergy measurements reactive power static meters reference standard meters power systems harmonicsAC powerAutomotive engineeringElectric power systemHardware_GENERALHarmonicsEnergy marketMetering modeElectricityElectrical and Electronic EngineeringbusinessInstrumentationSettore ING-INF/07 - Misure Elettriche E ElettronicheVoltage
researchProduct

A New Measurement Method for the Detection of Harmonic Sources in Power Systems Based on the Approach of the IEEE Std. 1459–2000

2010

In this paper, a novel single-point strategy is proposed for the detection of the harmonic sources in power systems. The method is an improvement of a strategy previously proposed by the authors; it is developed from the IEEE Std 1459-2000 approach and it can be entirely implemented in the time domain, thus simplifying the measurement system. The effectiveness of the proposed method is evaluated by introducing simple decision-making rules and by taking the presence of the measurement transducers into account. Several simulations and experimental tests are presented, showing that the enhanced strategy is able to give an useful information on the detection of the dominant harmonic source upst…

EngineeringTotal harmonic distortionbusiness.industrySystem of measurementEnergy Engineering and Power TechnologyAC powerlaw.inventionElectric power systemlawElectrical networkHarmonicElectronic engineeringUpstream (networking)Time domainElectrical and Electronic EngineeringbusinessSettore ING-INF/07 - Misure Elettriche E ElettronicheDetection of harmonic sources harmonic distortion IEEE Std. 1459–2000 power definitions power measurement power quality (PQ)IEEE Transactions on Power Delivery
researchProduct

A PC-based wattmeter for accurate measurements in sinusoidal and distorted conditions: Setup and experimental characterization

2012

This paper presents the development of a high-accuracy sampling wattmeter, which can be employed with both sinusoidal and distorted input signals. The proposed personal computer (PC)-based system is a simple, portable, and low-cost solution because it is based on two commercial data acquisition boards connected to a common PC. Owing to this solution, the voltage is sensed directly, avoiding expensive voltage dividers, while the current is sensed by means of a noninductive current shunt. Commercial software is also used for data processing and implementation of the virtual instrument. The setup of the PC-based wattmeter is described, with a detailed description of the correction strategy of …

EngineeringVirtual instrumentExperimental evaluationMeasurement uncertaintyNon-inductive currentsInput signalHarmonic distortionElectric power measurementlaw.inventionPC-basedData acquisitionlawExperimental testElectronic engineeringData acquisition harmonic distortion personal computer (PC) -based instrument power measurement power system measurements wattmetersElectrical and Electronic EngineeringSignal samplingInstrumentationVoltage dividersTotal harmonic distortionLow-cost solutionVirtual instrumentationbusiness.industryAnalog to digital convertersData acquisition boardExperimental characterizationVoltage dividerElectrical engineeringData acquisitionMetrological performanceWattmeterAccurate measurementCommercial softwareElectric powerPersonal computersPower qualityPersonal computerPower system measurementMeasurement uncertaintyUncertainty analysisbusinessHigh-accuracySettore ING-INF/07 - Misure Elettriche E ElettronicheWattmetersVoltage
researchProduct

Phase Margin Degradation of a Peak Current Controlled Converter at Reduced Duty Cycle

2010

An inner current loop is frequently used in many switching power supplies to achieve higher stability and a good current sharing. Nevertheless, some problems derived from its practical implementation can be encountered. One problem is related to the need of filtering of the sensed current and was discovered by the authors in the implementation of a 500 W converter, when peak current control was applied by sensing the switch current. This paper will demonstrate mathematically that an RC filter not only filters out the noise but also can cause a degradation of the phase margin, especially, if the needed duty cycle is close to zero. The main reason for it is the severe distortion of the curren…

Engineeringbusiness.industryLow-pass filterPhase distortionElectrical engineeringPhase (waves)Phase marginControl theoryDuty cycleElectrical and Electronic EngineeringbusinessRC circuitActive filterElectronic filterIEEE Transactions on Power Electronics
researchProduct

Impact of integrating photovoltaic based DG on distribution network harmonics

2017

The process of integrating various distributed generation (DG) technologies in power system networks is increasing rapidly in the recent years. One major concern about the integration of DGs is their impact on network harmonics. The aim of this paper is to investigate the effects caused by the integration of photovoltaic DG in distribution networks on system harmonics. The penetration level, number of DG units, and their location are used as parameters in order to verify the effects of DG on system harmonics. Moreover, a study of single and double tuned filters is conducted as harmonics mitigation techniques. Detailed simulations using Matlab/Simulink are inserted in order to explain and ve…

Engineeringdistributed generationDistribution networksbusiness.industry020209 energyPhotovoltaic systemElectrical engineeringProcess (computing)02 engineering and technologyphotovoltaicSettore ING-IND/33 - Sistemi Elettrici Per L'EnergiaElectric power systemDG integrationHarmonicsDistributed generation0202 electrical engineering electronic engineering information engineeringElectronic engineeringtotal harmonic distortionbusinessMATLABcomputercomputer.programming_language
researchProduct

Improvement of Hall Effect Current Transducer Metrological Performances in the Presence of Harmonic Distortion

2010

The performance of Hall effect current transducers (HECTs), under distorted waveform conditions, is usually characterized by means of a frequency response test. In this paper, it was investigated if frequency response is able to correctly evaluate the ratio and the phase errors under distorted conditions. Two HECTs, with the accuracy class level of 1% and 0.5%, respectively, were experimentally characterized under two conditions: 1) sinusoidal excitation with frequencies ranging from 50 to 750 Hz, which is the well-known frequency response test, and 2) nonsinusoidal excitation using fundamental frequency and one harmonic with adjusted amplitude and phase shift. It was found that ratio and p…

Frequency responseElectric current measurementCurrent measurement current transducer frequency response hall effect devices harmonic distortion power system harmonics.AcousticsTransducersPhase (waves)GyratorsNon-sinusoidal excitationHarmonic distortionAccuracy levelFundamental frequenciesHarmonic analysisPhase errorElectric currentsError compensationFrequency responseFrequency response testsWaveformSinusoidal excitationsPhase shiftElectrical and Electronic EngineeringInstrumentationPhysicsTotal harmonic distortionElectric power distributionHall effectCurrent measurementsMetrological performanceCurrent transducerFundamental frequencyLight measurementAmplitudeAccuracy classHarmonicsMagnetic field effectsHarmonicHarmonic amplitudeSettore ING-INF/07 - Misure Elettriche E ElettronicheDistorted waveformsHarmonic componentsHall effect devicesIEEE Transactions on Instrumentation and Measurement
researchProduct

Frequency response of Measurement Current Transformers

2008

In this paper the frequency response of two CTs is experimentally evaluated in the range of 30-600 Hz. A theoretical analysis of CTs behavior has been developed by means of the equivalent circuit. It was shown, by an experimental test, that, for the frequency range analyzed, the transformer equivalent circuit is a valid tool for the evaluation of CT performances.

Frequency responseTotal harmonic distortionMaterials scienceTransducerlawPower system harmonicsElectronic engineeringEquivalent circuitIec standardsTransformerCurrent transformerHardware_LOGICDESIGNlaw.invention2008 IEEE Instrumentation and Measurement Technology Conference
researchProduct

Analysis of Fresnel Zone Plates Focusing Dependence on Operating Frequency

2017

[EN] The focusing properties of Fresnel Zone Plates (FZPs) against frequency are analyzed in this work. It is shown that the FZP focal length depends almost linearly on the operating frequency. Focal depth and focal distortion are also considered, establishing a limit on the frequency span at which the operating frequency can be shifted. An underwater FZP ultrasound focusing system is demonstrated, and experimental results agree with the theoretical analysis and simulations.

Fresnel lensFresnel zoneOperating frequency02 engineering and technologySpan (engineering)lcsh:Chemical technology01 natural sciencesBiochemistryArticleAnalytical Chemistrylaw.inventionOpticsoperating frequencylawDistortion0103 physical sciencesLimit (music)TEORIA DE LA SEÑAL Y COMUNICACIONESFocal lengthlcsh:TP1-1185Electrical and Electronic EngineeringUnderwaterInstrumentationultrasonic lens010302 applied physicsPhysicsbusiness.industryFresnel lensultrasonic lens; Fresnel lens; focal depth; focal distortion; operating frequency021001 nanoscience & nanotechnologyfocal distortionAtomic and Molecular Physics and OpticsFISICA APLICADA0210 nano-technologybusinessfocal depthMATEMATICA APLICADASensors; Volume 17; Issue 12; Pages: 2809
researchProduct

Dead-time impact on the harmonic distortion and conversion efficiency in a three-phase five-level Cascaded H-Bridge inverter: mathematical formulatio…

2023

To avoid leg short-circuit in inverters, dead time must be introduced on leg gate signals. Dead time affects the inverter output voltage fundamental harmonic amplitude, voltage harmonic distortion and inverter efficiency by introducing additional voltage drops. In this regard, dead time effects have been widely investigated for traditional two-level three-phase voltage source inverters in the literature but not extensively for multilevel topology structures. This paper provides a detailed analysis of dead time impact on the harmonic distortion and efficiency of Cascaded H-Bridges Multilevel Inverters (CHBMIs). For this purpose, a general mathematical formulation to determine voltage drop du…

General Computer ScienceDead Time Efficiency Harmonic analysis Harmonic Distortion Inverters Modulation Multi Carrier PWM Multilevel Inverter Power harmonic filters Pulse width modulation Switching frequency VoltageGeneral EngineeringGeneral Materials ScienceElectrical and Electronic EngineeringSettore ING-IND/32 - Convertitori Macchine E Azionamenti Elettrici
researchProduct

Detection of Signals in MC–CDMA Using a Novel Iterative Block Decision Feedback Equalizer

2022

This paper presents a technique to mitigate multiple access interference (MAI) in multicarrier code division multiple access (MC-CDMA) wireless communications systems. Although under normal circumstances the MC-CDMA system can achieve high spectral efficiency and resistance towards inter symbol interference (ISI) however when exposed to substantial nonlinear distortion the issue of MAI manifests. Such distortion results when the power amplifiers are driven into saturation or when the transmit signal experiences extreme adverse channel conditions. The proposed technique uses a modified iterative block decision feedback equalizer (IB-DFE) that uses a minimal mean square error (MMSE) receiver …

General Computer ScienceIterative methodsMultiaccess communicationReceiversMMSENonlinear distortionCodesFeedbackCDMA[SPI]Engineering Sciences [physics]CDMA OFDM MAI MMSE IB-DFE Maximum Likelihood (ML)General Materials ScienceSpectral efficiencyMaximum likelihood (Ml)Electrical and Electronic EngineeringOFDMDecision feedback equalizers[PHYS]Physics [physics]TelecomunicacionesPower amplifiersGeneral EngineeringMAIMaximum Likelihood (ML)Multicarrier code division multiple accessAI and TechnologiesBit error rateIB-DFESignal detectionEngineering Research GroupIEEE Access
researchProduct