Search results for " Emission"
showing 10 items of 1496 documents
Sustainable Development and Energy Policy: Actual CO2 Emissions in the European Union in the Years 1997–2017, Considering Trade with China and the USA
2020
One of the ways of implementing the concept of sustainable development by the European Union is their energy policy. Among the three main objectives in its energy policy is a reduction in greenhouse gases (mainly CO2) emissions to at least 20% below 1990 levels by 2020. This study aims to assess the impact of international trade on actual CO2 emission in the EU, China and the USA for the period 1997–2017. For this aim, the Actual-Open CO2 emissions were calculated, taking into account the transfer of CO2 in exported products and services from China and the USA to the EU and vice versa. It is concluded that the actual CO2 emissions in China, the USA, and the EU differed from the traditionall…
Upward and downward solar-induced chlorophyll fluorescence yield indices of four tree species as indicators of traffic pollution in Valencia
2013
Abstract: Passive steady-state chlorophyll fluorescence (Fs) provides a direct diagnosis of the functional status of vegetation photosynthesis. With the prospect of mapping Fs using remote sensing techniques, field measurements are mandatory to understand to which extent Fs allows detecting plant stress in different environments. Trees of four common species in Valencia were classified in either a low or a high local traffic exposure class based on their leaf magnetic value. Upward and downward hyperspectral fluorescence yield (FY) and indices based on the two Fs peaks (at 687 and 741 nm) were calculated. FY indices of P. canariensis and P. x acerifolia were significantly different between …
Literature survey of the on-line preconcentration in flow-injection atomic spectrometric analysis
1992
The literature on the use of “on-line” preconcentration in flow injection atomic spectrometric analysis is reviewed, taking into account its application both in flame and electrothermal atomic absorption methods as well as in plasma emission spectrometry. The basis of the different preconcentration approaches, such as liquid-liquid extraction, column preconcentration and “on-line” precipitation are discussed. The literature survey reveals the analytical performance of the developed methodologies.
Chromium speciation in liquid matrices: a survey of the literature
2000
A thorough review of the literature published (1983 - March 1999) on chromium speciation in liquid samples is presented, and analytical techniques used in the 404 articles are summarized. The discussion focuses on atomic spectrometric techniques, which are mainly employed for chromium speciation in liquid matrices (134 articles). Details on the type of pretreatment, species, samples, techniques and analytical features of the methodologies proposed are given.
Determination of chromium in foods by flame atomic absorption and inductively coupled plasma spectrometry
1989
Critical single proximal left arterial descending coronary artery stenosis to mimic chronic myocardial ischemia: a new model induced by minimal invas…
2008
<i>Background/Aims:</i> The present report examines a new pig model for progressive induction of high-grade stenosis, for the study of chronic myocardial ischemia and the dynamics of collateral vessel growth. <i>Methods:</i> Thirty-nine Landrace pigs were instrumented with a novel experimental stent (GVD stent) in the left anterior descending coronary artery. Eight animals underwent transthoracic echocardiography at rest and under low-dose dobutamine. Seven animals were examined by nuclear PET and SPECT analysis. Epi-, mid- and endocardial fibrosis and the numbers of arterial vessels were examined by histology. <i>Results:</i> Functional analysis showed a…
Antennas for the detection of radio emission pulses from cosmic-ray induced air showers at the Pierre Auger Observatory.
2012
The Pierre Auger Observatory is exploring the potential of the radio detection technique to study extensive air showers induced by ultra-high energy cosmic rays. The Auger Engineering Radio Array (AERA) addresses both technological and scientific aspects of the radio technique. A first phase of AERA has been operating since September 2010 with detector stations observing radio signals at frequencies between 30 and 80 MHz. In this paper we present comparative studies to identify and optimize the antenna design for the final configuration of AERA consisting of 160 individual radio detector stations. The transient nature of the air shower signal requires a detailed description of the antenna s…
Measurement of the radiation energy in the radio signal of extensive air showers as a universal estimator of cosmic-ray energy
2016
We measure the energy emitted by extensive air showers in the form of radio emission in the frequency range from 30 to 80 MHz. Exploiting the accurate energy scale of the Pierre Auger Observatory, we obtain a radiation energy of 15.8±0.7(stat)±6.7(syst) MeV for cosmic rays with an energy of 1 EeV arriving perpendicularly to a geomagnetic field of 0.24 G, scaling quadratically with the cosmic-ray energy. A comparison with predictions from state-of-the-art first-principles calculations shows agreement with our measurement. The radiation energy provides direct access to the calorimetric energy in the electromagnetic cascade of extensive air showers. Comparison with our result thus allows the d…
Role of positron emission tomography (PET) in advanced stage non-small cell lung cancer patients treated with cisplatin-based doublets
2008
Effect of inter-crystal scatter on estimation methods for random coincidences and subsequent correction.
2008
Random coincidences can contribute substantially to the background in positron emission tomography (PET). Several estimation methods are being used for correcting them. The goal of this study was to investigate the validity of techniques for random coincidence estimation, with various low-energy thresholds (LETs). Simulated singles list-mode data of the MADPET-II small animal PET scanner were used as input. The simulations have been performed using the GATE simulation toolkit. Several sources with different geometries have been employed. We evaluated the number of random events using three methods: delayed window (DW), singles rate (SR) and time histogram fitting (TH). Since the GATE simula…