Search results for " Fourier Transform Infrared"
showing 10 items of 255 documents
Making Broad Proteome Protein Measurements in 1−5 min Using High-Speed RPLC Separations and High-Accuracy Mass Measurements
2005
The throughput of proteomics measurements that provide broad protein coverage is limited by the quality and speed of both the separations as well as the subsequent mass spectrometric analysis; at present, analysis times can range anywhere from hours (high throughput) to days or longer (low throughput). We have explored the basis for proteomics analyses conducted on the order of minutes using high-speed capillary RPLC combined through on-line electrospray ionization interface with high-accuracy mass spectrometry (MS) measurements. Short 0.8-microm porous C18 particle-packed 50-microm-i.d. capillaries were used to speed the RPLC separations while still providing high-quality separations. Both…
Clean method for the simultaneous determination of propyphenazone and caffeine in pharmaceuticals by flow injection Fourier transform infrared spectr…
1997
A procedure is proposed for the simultaneous FTIR determination of propyphenazone (PFZ) and caffeine (CAF) in pharmaceuticals. The method involves the dissolution of the active principles in CHCl 3 , followed by filtration of sample solutions to remove the excipients. PFZ is then determined by absorbance measurements at 1595 cm - 1 , using a baseline established between 2000 and 890 cm - 1 , and CAF by using the first-derivative values at 1712 cm - 1 , using solutions of PFZ and CAF for external calibration. The method was applied in both the stopped-flow and flow-injection modes, providing precise and accurate results for the analysis of real samples. The incorporation of a distillation un…
Using ATR-FTIR Spectroscopy To Design Active Antimicrobial Food Packaging Structures Based on High Molecular Weight Chitosan Polysaccharide
2007
ATR-FTIR spectroscopy has been used in this study to characterize the molecular mechanisms and kinetic processes that take place when a chitosonium acetate thin coating is put in contact with water solutions, Staphylococcus aureus solutions, microbial nutrient solutions, and with a high water activity TSA hydrogel medium to simulate the effect of direct contact with high moisture foods such as fresh meats, fish, and seafood products or beverages. The results of this work suggest that the biocide carboxylate groups that form when chitosan is cast from acetic acid solutions are being continuously evaporated from the formed film in the form of acetic acid (mechanism I) in the presence of envir…
Biogenic synthesis of palladium nanoparticles using Pulicaria glutinosa extract and their catalytic activity towards the Suzuki coupling reaction.
2014
Green synthesis of nanomaterials finds the edge over chemical methods due to its environmental compatibility. Herein, we report a facile and eco-friendly method for the synthesis of palladium (Pd) nanoparticles (NPs) using an aqueous solution of Pulicaria glutinosa, a plant widely found in a large region of Saudi Arabia, as a bioreductant. The as-prepared Pd NPs were characterized using ultraviolet-visible (UV-vis) spectroscopy, powder X-ray diffraction (XRD), transmission electron microscopy (TEM), energy-dispersive X-ray spectroscopy (EDX), and Fourier transform-infrared spectroscopy (FT-IR). The hydroxyl groups of the plant extract (PE) molecules were found mainly responsible for the red…
Application of point-to-point matching algorithms for background correction in on-line liquid chromatography–Fourier transform infrared spectrometry …
2009
A new background correction method for the on-line coupling of gradient liquid chromatography and Fourier transform infrared spectrometry has been developed. It is based on the use of a point-to-point matching algorithm that compares the absorption spectra of the sample data set with those of a previously recorded reference data set in order to select an appropriate reference spectrum. The spectral range used for the point-to-point comparison is selected with minimal user-interaction, thus facilitating considerably the application of the whole method. The background correction method has been successfully tested on a chromatographic separation of four nitrophenols running acetonitrile (0.08…
Partial least squares attenuated total reflectance IR spectroscopy versus chromatography: the greener method
2012
Method election is a complex task that must be done carefully in order to ensure the capability of analytical methodologies to provide appropriate data for problem solving. This is a real challenge in all fields, but especially with bioanalysis, which in many cases involves the need to do a large number of determinations in complex
Univariate method for background correction in liquid chromatography–Fourier transform infrared spectrometry
2007
An univariate method is proposed for background correction in on-line gradient liquid chromatography-Fourier transform infrared (LC-FTIR) spectrometry using acetonitrile:water as mobile phase components. The method is based on the calculation of the ratio of absorbances (AR) at two characteristic wavenumbers for each spectrum. This parameter is subsequently used to locate the most appropriated eluent spectrum within a reference spectra matrix (RSM) to be subtracted from each spectrum included in the sample chromatogram. To correct minor changes in eluent spectra intensity during the elution of analytes, a correction factor (Kf), defined as the ratio of the absorbance of the sample and the s…
Infrared biospectroscopy for a fast qualitative evaluation of sample preparation in metabolomics.
2014
Liquid chromatography-mass spectrometry (LC-MS) has been increasingly used in biomedicine to study the dynamic metabolomic responses of biological systems under different physiological or pathological conditions. To obtain an integrated snapshot of the system, metabolomic methods in biomedicine typically analyze biofluids (e.g. plasma) that require clean-up before being injected into LC-MS systems. However, high resolution LC-MS is costly in terms of resources required for sample and data analysis and care must be taken to prevent chemical (e.g. ion suppression) or statistical artifacts. Because of that, the effect of sample preparation on the metabolomic profile during metabolomic method d…
Determination of lecithin and soybean oil in dietary supplements using partial least squares-Fourier transform infrared spectroscopy.
2008
Lecithin and soybean oil in dietary supplements were determined by Fourier transform infrared spectrometry transmission measurements in dichloromethane in combination with a partial least squares (PLS) regression. Two different PLS models were developed, using 16 synthetic mixtures of analytes in dichloromethane, making measurements in the spectral range from 931.8 to 1252.3 cm(-1) for lecithin and from 911.4 to 1246.9 cm(-1) and 1695.3 to 1774.5 cm(-1) for soybean oil. Seven products from the Spanish market with lecithin concentrations between 21.1% and 99.1% and soybean oil concentrations between 0% and 37.2% were analyzed by the proposed method and the data was compared to a chromatograp…
The chemistry of Cr(VI) adsorption on to poly(p-phenylenediamine) adsorbent
2019
Abstract Water pollution due to industrial processes has necessitated and spurred robust research into the development of adsorbent materials for remediation. Polyphenylenediamines (PPD) have attracted significant attention because of their dual cationic and redox properties. They are able to reduce Cr(VI) to Cr(III) in solution. Interrogation of the chemical processes involved in the Cr(VI) adsorption on para-PPD was primarily by X-ray photoelectron spectroscopy (XPS) and Fourier transform infrared (FT-IR) spectroscopy. It was confirmed that the underlying oxidation of the amino groups to imines during the reduction of Cr(VI) to Cr(III) was irreversible. This process occurred at both acidi…