Search results for " HPLC"
showing 10 items of 81 documents
Interpretive optimisation of organic solvent content and flow-rate in the separation of β-blockers with a Chromolith RP-18e column
2009
The chromatographic performance of a Chromolith RP-18e column was comprehensively examined for a group of basic drugs (beta-blockers), eluted with isocratic ACN-water mixtures at increasing flow-rate up to 6 mL/min. As the flow-rate increases at fixed mobile phase composition, peak distribution (selectivity) is maintained, but the relative peak widths increase. This reduces the resolution below satisfactory values for closely eluting compounds. With the monolithic column, flow-rate becomes thus an important factor to be optimised, in addition to the mobile phase composition. Since, theoretically, retention factors (k) are independent of the flow-rate, the classical quadratic model relating …
Impact of pore structural parameters on column performance and resolution of reversed-phase monolithic silica columns for peptides and proteins
2007
In this work, monolithic silica columns with the C4, C8, and C18 chemistry and having various macropore diameters and two different mesopore diameters are studied to access the differences in the column efficiency under isocratic elution conditions and the resolution of selected peptide pairs under reversed-phase gradient elution conditions for the separation of peptides and proteins. The columns with the pore structural characteristics that provided the most efficient separations are then employed to optimize the conditions of a gradient separation of a model mixture of peptides and proteins based on surface chemistry, gradient time, volumetric flow rate, and acetonitrile concentration. Bo…
Resolution of inherently chiral resorcarene derivatives by enantioselective HPLC
1999
Abstract The HPLC enantiomeric resolution of five inherently chiral tetrabenzoxazine derivatives of resorcarenes has been achieved by HPLC using Whelk-Ol and in one case Chiralpak AD as stationary phases. Enantiomeric separation was only observed in a very narrow range of mobile phase compositions. On-column enantiomeric interconversion of a racemic compound with a typical plateau-like elution profile was observed using a Chiralpak AD column
Separation, isolation and stereochemical assignment of imazalil enantiomers and their quantitation in an in vitro toxicity test
2016
A simple method for the separation of the enantiomers of the fungicide imazalil was developed. Racemic imazalil was separated into its enantiomers with an enantiomeric purity of 99% using HPLC-UV with an enantioselective column (permethylated cyclodextrin) operated in reversed phase mode (water with 0.2% trimethylamine and 0.08% acetic acid and methanol). The absolute configuration of the separated enantiomers was assigned and unequivocally confirmed by optical rotation as well as by vibrational circular dichroism (VCD) and electronic circular dichroism (ECD) combined with ab-initio calculations. The same enantioselective column was also used to develop an HPLC-MS/MS method for the quantifi…
Novel σ1 antagonists designed for tumor therapy: Structure – activity relationships of aminoethyl substituted cyclohexanes
2021
Abstract Depending on the substitution pattern and stereochemistry, 1,3-dioxanes 1 with an aminoethyl moiety in 4-position represent potent σ1 receptor antagonists. In order to increase the stability, a cyclohexane ring first replaced the acetalic 1, 3-dioxane ring of 1. A large set of aminoethyl substituted cyclohexane derivatives was prepared in a six-step synthesis. All enantiomers and diastereomers were separated by chiral HPLC at the stage of the primary alcohol 7, and their absolute configuration was determined by CD spectroscopy. Neither the relative nor the absolute configuration had a large impact on the σ1 affinity. The highest σ1 affinity was found for cis-configured benzylamines…
Advantages of monolithic over particulate columns for multiresidue analysis of organic pollutants by in-tube solid-phase microextraction coupled to c…
2011
Abstract The performance of a monolithic C 18 column (150 mm × 0.2 mm i.d.) for multiresidue organic pollutants analysis by in-tube solid-phase microextraction (IT-SPME)-capillary liquid chromatography has been studied, and the results have been compared with those obtained using a particulate C 18 column (150 mm × 0.5 mm i.d., 5 μm). Chromatographic separation has been carried out under isocratic elution conditions, and for detection and identification of the analytes a UV-diode array detector has been employed. Several compounds of different chemical structure and hydrophobicity have been used as model compounds: simazine, atrazine and terbutylazine (triazines), chlorfenvinphos and chlorp…
In-tube solid-phase microextraction and liquid chromatography using a monolithic column for the selective determination of residual ethylenediamine i…
2009
The selective determination of the diamine ethylenediamine (EDA) in the presence of a higher amount of residual dimethylamine in cationic polymers has been developed. The strategy uses both a solution derivatization with a selective agent of primary amines such as o-phthaldialdehyde-N-acetyl-L-cysteine (OPA-NAC) and an in-tube solid-phase microextraction (IT-SPME) coupled to liquid chromatography (LC). A 70 cm long, 0.32 mm internal diameter, and 3 microm thick commercially available capillary column coated with 95% polydimethylsiloxane and 5% polydiphenylsiloxane was employed to replace the injection loop of a Rheodyne injection valve. A volume of 1 mL of derivatized sample was passed thro…
Synthesis of 8-aminomorphans with high KOR affinity
2021
2-Azabicyclo[3.3.1]nonanes (morphans) with a (3,4-dichlorophenyl)acetyl group at 2-position and a pyrrolidino moiety at 8-position were designed as conformationally restricted analogs of piperidine-based KOR agonists. The synthesis started with 4-oxopiperidine-2-carboxylic acid comprising 13 reaction steps. At first the ketone 10 was transformed into diester 7 bearing a propionate side chain. Dieckmann condensation of diester 7 to afford bicyclic enolester 14 and subsequent Krapcho deethoxycarbonylation represent the key steps of the synthesis. The enantiomeric pyrrolidines (1S,5R,8R)-5a and (1R,5S,8S)-5a were separated by chiral HPLC. The eutomer (1S,5R,8R)-5a showed high KOR affinity (K-i…
Enantiomerization of an inherently chiral resorcarene derivative: determination of the interconversion barrier by computer simulation of the dynamic …
2001
Abstract The inherently chiral tetrabenzoxazine resorcarene derivative 1 shows characteristic plateau-formation during enantioselective HPLC separation on the chiral stationary phase Chiralpak AD. By computer assisted peak form analysis of the elution profiles, obtained from temperature dependent dynamic HPLC (DHPLC) experiments, with ChromWin, the enantiomerization barrier Δ G # (298 K)=92±2 kJ mol −1 and the activation parameters Δ H # =53.0±1.8 kJ mol −1 and Δ S # =−131±14 J (K mol) −1 were determined.
Sensitive determination of polycyclic aromatic hydrocarbons in water samples using monolithic capillary solid-phase extraction and on-line thermal de…
2011
A methacrylate-based monolithic capillary column has been evaluated for the preconcentration of polycyclic aromatic hydrocarbons (PAHs) from environmental water samples. For this purpose, the monolyte was in situ synthesized in a 6cm×0.32mm id fused-silica capillary. The microextraction unit was fitted to a micro-HPLC pump to pass 10mL of sample. The isolated pollutants were eluted by means of 10μL of methanol, the organic phase being directly collected in a specific interface that can be fitted to the injection port of the gas chromatograph without modification. The interface allows the on-line thermal desorption of the PAHs, avoiding the dilution and providing enough sensitivity to reach …