Search results for " Informatica"
showing 10 items of 978 documents
Path Following in Non-Visual Conditions.
2018
Path-following tasks have been investigated mostly under visual conditions, that is when subjects are able to see both the path and the tool, or limb, used for navigation. Moreover, only basic path shapes are usually adopted. In the present experiment, participants must rely exclusively on continuous, non-speech, and ecological auditory and vibrotactile cues to follow a path on a flat surface. Two different, asymmetric path shapes were tested. Participants navigated by moving their index finger over a surface sensing position and force. Results show that the different non-visual feedback modes did not affect the task's accuracy, yet they affected its speed, with vibrotactile feedback causin…
k-Nearest neighbour local linear prediction of scalp EEG activity during intermittent photic stimulation
2011
The characterization of the EEG response to photic stimulation (PS) is an important issue with significant clinical relevance. This study aims to quantify and map the complexity of the EEG during PS, where complexity is measured as the degree of unpredictability resulting from local linear prediction. EEG activity was recorded with eyes closed (EC) and eyes open (EO) during resting and PS at 5, 10, and 15. Hz in a group of 30 healthy subjects and in a case-report of a patient suffering from cerebral ischemia. The mean squared prediction error (MSPE) resulting from k-nearest neighbour local linear prediction was calculated in each condition as an index of EEG unpredictability. The linear or …
Comparison of Methods for the Assessment of Nonlinearity in Short-Term Heart Rate Variability under different Physiopathological States
2019
Despite the widespread diffusion of nonlinear methods for heart rate variability (HRV) analysis, the presence and the extent to which nonlinear dynamics contribute to short-term HRV are still controversial. This work aims at testing the hypothesis that different types of nonlinearity can be observed in HRV depending on the method adopted and on the physiopathological state. Two entropy-based measures of time series complexity (normalized complexity index, NCI) and regularity (information storage, IS), and a measure quantifying deviations from linear correlations in a time series (Gaussian linear contrast, GLC), are applied to short HRV recordings obtained in young (Y) and old (O) healthy su…
Cardiovascular control and time domain granger causality: Insights from selective autonomic blockade
2013
We studied causal relations among heart period (HP), systolic arterial pressure (SAP) and respiration (R) according to the definition of Granger causality in the time domain. Autonomic pharmacological challenges were used to alter the complexity of cardiovascular control. Atropine (AT), propranolol and clonidine (CL) were administered to block muscarinic receptors, β-adrenergic receptors and centrally sympathetic outflow, respectively. We found that: (i) at baseline, HP and SAP interacted in a closed loop with a dominant causal direction from HP to SAP; (ii) pharmacological blockades did not alter the bidirectional closed-loop interactions between HP and SAP, but AT reduced the dominance of…
Redundant and synergistic information transfer in cardiovascular and cardiorespiratory variability
2015
In the framework of information dynamics, new tools are emerging which allow one to quantify how the information provided by two source processes about a target process results from the contribution of each source and from the interaction between the sources. We present the first implementation of these tools in the assessment of short-term cardiovascular and cardiorespiratory variability, by introducing two strategies for the decomposition of the information transferred to heart period (HP) variability from systolic arterial pressure (SAP) and respiration flow (RF) variability. Several measures based on the notion of transfer entropy (TE) are defined to quantify joint, individual and redun…
Instantaneous transfer entropy for the study of cardio-respiratory dynamics
2015
Measures of transfer entropy have been proposed to quantify the directional coupling and strength between two complex physiological variables. Particular attention has been given to nonlinear interactions within cardiovascular and respiratory dynamics as influenced by the autonomic nervous system. However, standard transfer entropy estimates have shown major limitations in dealing with issues concerning stochastic system modeling, limited observations in time, and the assumption of stationarity of the considered physiological variables. Moreover, standard estimates are unable to track time-varying changes in nonlinear coupling with high resolution in time. Here, we propose a novel definitio…
An Information-Theoretic Framework to Map the Spatiotemporal Dynamics of the Scalp Electroencephalogram
2016
We present the first application of the emerging framework of information dynamics to the characterization of the electroencephalography (EEG) activity. The framework provides entropy-based measures of information storage (self entropy, SE) and information transfer (joint transfer entropy (TE) and partial TE), which are applied here to detect complex dynamics of individual EEG sensors and causal interactions between different sensors. The measures are implemented according to a model-free and fully multivariate formulation of the framework, allowing the detection of nonlinear dynamics and direct links. Moreover, to deal with the issue of volume conduction, a compensation for instantaneous e…
Instantaneous Transfer Entropy for the Study of Cardiovascular and Cardio-Respiratory Nonstationary Dynamics
2017
Objective: Measures of transfer entropy (TE) quantify the direction and strength of coupling between two complex systems. Standard approaches assume stationarity of the observations, and therefore are unable to track time-varying changes in nonlinear information transfer with high temporal resolution. In this study, we aim to define and validate novel instantaneous measures of TE to provide an improved assessment of complex nonstationary cardiorespiratory interactions. Methods: We here propose a novel instantaneous point-process TE (ipTE) and validate its assessment as applied to cardiovascular and cardiorespiratory dynamics. In particular, heartbeat and respiratory dynamics are characteriz…
Lag-specific transfer entropy as a tool to assess cardiovascular and cardiorespiratory information transfer
2014
In the study of interacting physiological systems, model-free tools for time series analysis are fundamental to provide a proper description of how the coupling among systems arises from the multiple involved regulatory mechanisms. This study presents an approach which evaluates direction, magnitude, and exact timing of the information transfer between two time series belonging to a multivariate dataset. The approach performs a decomposition of the well-known transfer entropy (TE) which achieves 1) identifying, according to a lag-specific information-theoretic formulation of the concept of Granger causality, the set of time lags associated with significant information transfer, and 2) assig…
Quantifying Net Synergy/Redundancy of Spontaneous Variability Regulation via Predictability and Transfer Entropy Decomposition Frameworks.
2017
Objective: Indexes assessing the balance between redundancy and synergy were hypothesized to be helpful in characterizing cardiovascular control from spontaneous beat-to-beat variations of heart period (HP), systolic arterial pressure (SAP), and respiration (R). Methods: Net redundancy/synergy indexes were derived according to predictability and transfer entropy decomposition strategies via a multivariate linear regression approach. Indexes were tested in two protocols inducing modifications of the cardiovascular regulation via baroreflex loading/unloading (i.e., head-down tilt at −25° and graded head-up tilt at 15°, 30°, 45°, 60°, 75°, and 90°, respectively). The net redundancy/synergy of …