Search results for " Infrared"
showing 10 items of 945 documents
Liquid chromatography-Fourier transform infrared spectrometric determination of cholesterol in animal greases
1997
Abstract Stearic acid, cholesterol and cholesteryl palmitate have been separated in less than 14 min by liquid chromatography on a column (3.9 mm i.d.×150 mm) of Nova-Pack C 18 (5 μm) using chloroform–acetonitrile (45 : 55) as mobile phase pumped at 0.5 ml min −1 ; Fourier transform infrared (FTIR) spectrometry was employed for both, general detection at 2868 or 2855 cm −1 and selective detection at 3285 cm −1 for stearic acid and 3526 cm −1 for cholesterol. In all cases a baseline established at 3900 cm −1 , 9-point smoothing and chromatographic peak height measurements were used. The method has been validated by application to the determination of cholesterol in animal greases and fish oi…
Comparison of two vibrational procedures for the direct determination of mancozeb in agrochemicals.
2007
The direct determination of mancozeb in agrochemicals has been made by diamond attenuated total reflectance (ATR) Fourier transform infrared spectroscopy in the middle range (DATR-MIR) and diffuse reflectance infrared Fourier transform spectroscopy in the near range (DR-NIR) methods using in both cases a previous identification of the samples using a dendrographic classification and an appropriate partial least squares (PLS) calibration established from a set of nine external standards and optimized for each type of sample. It was analyzed a heterogeneous population of 11 samples obtained from the Spanish market, containing different co-formulated products, such as fosetyl-Al, copper oxychl…
Filter-based infrared detectors for high temperature size exclusion chromatography analysis of polyolefins: calibration with a small number of standa…
2012
Infrared detection has been shown to be very appropriate for high temperature analysis of polyolefins. After some early reports in which dispersive or single-band filter-based detectors were applied, Fourier transform detectors have been described for this application, in order to improve the method sensitivity. Modern simple filter-based detectors prove, however, comparable sensitivity while providing a number of practical advantages when coupled to chromatographic systems: reduced cell volume, simplified hardware, continuous generation of absorbance chromatograms, as well as simpler data collection and processing. A practical method for calibration, using multiple-band signals obtained wi…
Miniature diamond-anvil cells for FTIR-microspectroscopy of small quantities of biosamples.
2018
Fourier transform infrared (FTIR) spectroscopy techniques and data analyses have become widely available, are easy to use, and are convenient for studies of various biosamples, especially in biomedical science. Yet, cultivation of cells and purification of cell components are costly, often methodically challenging, and time and labor consuming. Therefore, reduction of the sample amount is of high value. Here we propose a novel method for the analysis of small quantities of biosamples by FTIR-microscopy of dry films using a diamond-anvil cell (DAC). This approach allows us to decrease the sample volume at least a hundred times compared to that for a high-throughput screening device (HTS-XT, …
Essential oil counterfeit identification through middle infrared spectroscopy
2018
Abstract Infrared spectroscopy (FTIR) has been employed for a fast quality control of commercial essential oils from different plant species. 47 samples were obtained from Algerian and Spanish market and directly measured, without any previous treatment, by attenuated total reflectance Fourier transform Infrared spectroscopy (ATR-FTIR), in the wavenumber region between 4000 and 550 cm−1. Pure essential oils were obtained by hydro- and steam-distillation extraction methods and their ATR spectra obtained. Results found evidenced the presence of solvents in some commercial formulations and permitted a rapid authentication of pure essential oils correctly extracted from those diluted. The propo…
Infrared biospectroscopy for a fast qualitative evaluation of sample preparation in metabolomics.
2014
Liquid chromatography-mass spectrometry (LC-MS) has been increasingly used in biomedicine to study the dynamic metabolomic responses of biological systems under different physiological or pathological conditions. To obtain an integrated snapshot of the system, metabolomic methods in biomedicine typically analyze biofluids (e.g. plasma) that require clean-up before being injected into LC-MS systems. However, high resolution LC-MS is costly in terms of resources required for sample and data analysis and care must be taken to prevent chemical (e.g. ion suppression) or statistical artifacts. Because of that, the effect of sample preparation on the metabolomic profile during metabolomic method d…
Stopped-flow Fourier-transform infra-red spectrometric speciation of glycolic and lactic acids in cosmetic formulations
2001
The dermatological activity of cosmetic formulations containing alpha-hydroxyacids depends on their different chemical forms, and it is therefore useful to determine these species in the finished products. In the present report a new procedure for studying the protonation equilibria of glycolic and lactic acids by stopped-flow Fourier-transform infra-red (FTIR) spectrometry is described. The procedure was validated for use in the speciation of glycolic and lactic acids in cosmetic formulations, with preferential attention given to glycolic acid, which is the most widely used. Species of these alpha-hydroxyacids can be approximately determined at different pHs and the total content of each a…
Spectrophotometric Determination of Hydralazine with 2-Hydroxy-1-naphthaldehyde in Pharmaceuticals
1991
Abstract A new extraction-spectrophotometric method for the determination of hydralazine, based on its reaction with 2-hydroxy-1-naphthaldehyde at 25 °C, is described. The calibration curve was linear between 0.4 and 6 mg/mL of hydralazine. The molar absorbtivity of the product at 408 nm is 40 900 L · mol − 1 · cm − 1 . The method described was applied to the analysis of hydralazine in pharmaceutical preparations containing reserpine, hydrochlorothiazide, bendrofluorthiazine, propranolol, and other substances. The agreement with the U.S.P. XXI method was satisfactory for tablets and injections, but not for pellets.
Determination of lecithin and soybean oil in dietary supplements using partial least squares-Fourier transform infrared spectroscopy.
2008
Lecithin and soybean oil in dietary supplements were determined by Fourier transform infrared spectrometry transmission measurements in dichloromethane in combination with a partial least squares (PLS) regression. Two different PLS models were developed, using 16 synthetic mixtures of analytes in dichloromethane, making measurements in the spectral range from 931.8 to 1252.3 cm(-1) for lecithin and from 911.4 to 1246.9 cm(-1) and 1695.3 to 1774.5 cm(-1) for soybean oil. Seven products from the Spanish market with lecithin concentrations between 21.1% and 99.1% and soybean oil concentrations between 0% and 37.2% were analyzed by the proposed method and the data was compared to a chromatograp…
The chemistry of Cr(VI) adsorption on to poly(p-phenylenediamine) adsorbent
2019
Abstract Water pollution due to industrial processes has necessitated and spurred robust research into the development of adsorbent materials for remediation. Polyphenylenediamines (PPD) have attracted significant attention because of their dual cationic and redox properties. They are able to reduce Cr(VI) to Cr(III) in solution. Interrogation of the chemical processes involved in the Cr(VI) adsorption on para-PPD was primarily by X-ray photoelectron spectroscopy (XPS) and Fourier transform infrared (FT-IR) spectroscopy. It was confirmed that the underlying oxidation of the amino groups to imines during the reduction of Cr(VI) to Cr(III) was irreversible. This process occurred at both acidi…