Visual acuity tolerance to residual refractive errors in patients with an apodized diffractive intraocular lens.

2007

To assess visual acuity tolerance to defocus caused by residual refractive errors after clear lens extraction (CLE) with apodized diffractive intraocular lens (IOL) implantation.Fernández-Vega Ophthalmological Institute, Oviedo, Spain.In this prospective study, 150 eyes of 75 consecutive patients who had bilateral CLE with implantation of an AcrySof ReSTOR Natural IOL (Alcon) were evaluated. The eyes were divided into 2 groups: myopia and hyperopia. Residual refractive errors were analyzed using vector analysis. Monocular and binocular uncorrected distance visual acuity, best corrected distance visual acuity, uncorrected distance near visual acuity, and best distance-corrected near visual a…

MaleRefractive errormedicine.medical_specialtyVisual acuitygenetic structuresPseudophakiaEye diseasemedicine.medical_treatmentAcrylic ResinsVisual AcuityIntraocular lensResidualVision disorderPostoperative ComplicationsApodizationLens Implantation IntraocularOphthalmologyLens CrystallinemedicineHumansProspective StudiesAgedLenses IntraocularMonocularbusiness.industryMiddle Agedmedicine.diseaseRefractive Errorseye diseasesSensory SystemsOphthalmologyOptometrySurgeryFemalesense organsmedicine.symptombusinessJournal of cataract and refractive surgery
researchProduct

Foldable toric intraocular lens for astigmatism correction in cataract patients.

2007

PURPOSE: To evaluate the results of AcrySof toric intraocular lens (IOL) (Alcon) implantation to correct preexisting astigmatism in patients having cataract surgery. SETTING: Ophthalmology Service, Donostia Hospital, San Sebastian, Spain. METHODS: This prospective observational study included 30 eyes of 15 consecutive patients with more than 1.00 diopter (D) of preexisting corneal astigmatism having cataract surgery. Bilateral implantation of the AcrySof toric IOL was performed after phacoemulsification. The uncorrected visual acuity (UCVA), best corrected visual acuity (BCVA), residual refractive sphere, residual keratometric and refractive cylinders, and toric IOL axis were measured. RESU…

MaleRefractive errormedicine.medical_specialtygenetic structuresmedicine.medical_treatmentAcrylic ResinsVisual AcuityIntraocular lensAstigmatismRefraction OcularVision disorderLens Implantation IntraocularOphthalmologymedicineHumansProspective StudiesDioptreAgedAged 80 and overLenses IntraocularPhacoemulsificationbusiness.industryAstigmatismPhacoemulsificationCataract surgeryMiddle Agedmedicine.diseaseeye diseasesSensory SystemsToric lensOphthalmologyOptometrySurgeryFemalesense organsmedicine.symptombusinessJournal of cataract and refractive surgery
researchProduct

Outcomes of cataract surgery in diabetic patients: results of the Pan American Collaborative Retina Study Group.

2014

Purpose: This study was designed to evaluate the visual and anatomical outcomes after cataract surgery in diabetic patients with different intraoperative therapeutic strategies. Methods: The research design comprised of a multicentric, retrospective, interventional study conducted at 6 centers in Argentina, Brazil, Costa Rica, Puerto Rico, Spain, and Venezuela. We included 138 diabetic patients with at least 6-month follow-up following phacoemulsification and intraocular lens implantation. Best-corrected visual acuity (BCVA) and central subfield thickness were collected at baseline and at 1-, 2-, 3-, and 6-month follow-up. Of these, 42 cases were not treated with any intraoperative coadjuva…

MaleVascular Endothelial Growth Factor ATriamcinolone acetonideVisual acuitygenetic structuresmedicine.medical_treatmentExtração de catarataVisual AcuityIntraocular lensCuidados intraoperatóriosAngiogenesis InhibitorsTriamcinolonelcsh:OphthalmologyLens Implantation IntraocularDiabetic retinopathyAntibodies monoclonalAged 80 and overGeneral MedicineDiabetic retinopathyMiddle AgedMulticenter studyBevacizumabTreatment OutcomeCataract extractionChemotherapy AdjuvantEstudo multicêntricoIntravitreal InjectionsFemalemedicine.symptommedicine.drugAdultmedicine.medical_specialtyBevacizumabAntibodies Monoclonal HumanizedCataractMacular EdemaIntraoperative careOphthalmologyEdema macularmedicineAnticorpos monoclonaisHumansMacular edemaGlucocorticoidsAgedRetrospective StudiesMacular edemaDiabetic RetinopathyIntraoperative CarePhacoemulsificationbusiness.industryRetinopatia diabéticaPhacoemulsificationCataract surgeryFacoemulsificaçãomedicine.diseaseSurgeryImplante de lente intraocularOphthalmologyLens implantation intraocularlcsh:RE1-994businessFollow-Up StudiesArquivos brasileiros de oftalmologia
researchProduct

Visual function comparison of 2 aspheric multifocal intraocular lenses

2011

To compare visual function after bilateral implantation of the multifocal Lentis Mplus LS-312 with a nonrotational symmetrical design (copolymer aspheric) or the Acrysof Restor SN6AD1 +3.0 D (hybrid aspheric) intraocular lens (IOL).Fernández-Vega Ophthalmological Institute, Oviedo, Spain.Comparative case series.Six months postoperatively, corrected distance visual acuity (CDVA), distance-corrected near visual acuity (DCNVA), the defocus curve, and photopic and mesopic contrast sensitivity with and without glare were measured.The mean CDVA was 0.02 ± 0.06 (SD) with the copolymer aspheric IOL and -0.06 ± 0.05 logMAR with the hybrid aspheric IOL (P=.07) and the mean DCNVA, 0.10 ± 0.06 and -0.0…

MaleVisual acuityPseudophakiagenetic structuresMesopic visionmedicine.medical_treatmentmedia_common.quotation_subjectVisual AcuityIntraocular lensGlareContrast SensitivityLens Implantation IntraocularmedicineHumansContrast (vision)Prospective StudiesMathematicsmedia_commonLenses IntraocularPhacoemulsificationGlare (vision)Middle AgedMultifocal intraocular lenseye diseasesSensory SystemsOphthalmologyVisual functionOptometryFemaleSurgerysense organsmedicine.symptomPhotopic visionJournal of Cataract and Refractive Surgery
researchProduct

Refractive lens exchange with a multifocal diffractive aspheric intraocular lens

2012

PURPOSE: To evaluate the safety, efficacy and predictability after refractive lens exchange with multifocal diffractive aspheric intraocular lens implantation. METHODS: Sixty eyes of 30 patients underwent bilateral implantation with AcrySof® ReSTOR® SN6AD3 intraocular lens with +4.00 D near addition. Patients were divided into myopic and hyperopic groups. Monocular best corrected visual acuity at distance and near and monocular uncorrected visual acuity at distance and near were measured before and 6 months postoperatively. RESULTS: After surgery, uncorrected visual acuity was 0.08 ± 0.15 and 0.11 ± 0.14 logMAR for the myopic and hyperopic groups, respectively (50% and 46.67% of patients ha…

MaleVisual acuitygenetic structuresDesenho de prótesesmedicine.medical_treatmentVisual AcuityEmmetropiaIntraocular lensProsthesis designMyopia/surgerylaw.inventionNear visionLens Implantation Intraocularlcsh:OphthalmologylawTonometry ocularMyopiaProspective StudiesLenses IntraocularLens crystalline/surgeryAcuidade visualGeneral MedicineMiddle AgedLens (optics)HyperopiaTreatment OutcomeFemalemedicine.symptomLens crystallinemedicine.medical_specialtyVisual acuityMiopiaRefractive lens exchangeProsthesis DesignStatistics NonparametricOphthalmologyLens CrystallinemedicineHumansHyperopia/physiopathologyHipermetropiaCristalinoAgedPhacoemulsificationbusiness.industryReproducibility of ResultsPhacoemulsificationPresbyopiamedicine.diseaseeye diseasesOphthalmologyLens implantation intraocularlcsh:RE1-994OptometryImplantação de lentes intraocularessense organsbusinessArquivos Brasileiros de Oftalmologia
researchProduct

Correlation of pupil size with visual acuity and contrast sensitivity after implantation of an apodized diffractive intraocular lens

2007

To determine whether pupil size is correlated with visual acuity and contrast sensitivity at all distances in eyes with an apodized diffractive intraocular lens (IOL).Private Clinic, Oviedo, Spain.Six months after surgery, the best corrected distance visual acuity, best distance-corrected near visual acuity, intermediate visual acuity, and distance contrast sensitivity under photopic (85 cd/m2) and mesopic (5 cd/m2) conditions were measured in 670 eyes of 335 consecutive patients who had implantation of the AcrySof ReSTOR Natural IOL (SN60D3, Alcon). Pupil diameters in distance vision were measured using a pupillometer.The logMAR best corrected distance acuity was significantly better with …

MaleVisual acuitygenetic structuresMesopic visionmedia_common.quotation_subjectmedicine.medical_treatmentAcrylic ResinsVisual AcuityIntraocular lensProsthesis DesignPupilContrast SensitivityCorrelationLens Implantation IntraocularHumansMedicineContrast (vision)Prospective Studiesmedia_commonLenses Intraocularbusiness.industryPupilMiddle Agedeye diseasesSensory SystemsOphthalmologyOptometryFemaleSurgerysense organsSpatial frequencymedicine.symptombusinessPhotopic visionJournal of Cataract and Refractive Surgery
researchProduct

Bilateral implantation of the Acri.LISA bifocal intraocular lens in myopic eyes.

2009

Purpose To asses visual quality after bilateral implantation of the Acri.LISA 366D intraocular lens (IOL) (Carl Zeiss Meditec) in patients with high and low–moderate myopia. Methods A total of 304 eyes of 152 patients had bilateral implantation of the Acri.LISA 366D IOL. The patients were divided into 2 groups: low–moderate myopia (IOL power from 15 to 20.5 D) and high myopia (IOL power from 0 to 14.5 D). Monocular and binocular best-corrected distance visual acuity (BCVA) and best distance-corrected near visual acuity (BCNVA), binocular best distance-corrected intermediate visual acuity (BCIVA), and distance contrast sensitivity (OS) under photopic (85 cd/m2) and mesopic (5 cd/m2) conditio…

MaleVisual acuitygenetic structuresMesopic visionmedicine.medical_treatmentVisual AcuityIntraocular lensExtractionFunctional LateralityTratamiento médico0302 clinical medicineLens Implantation IntraocularMyopiaContrast (vision)MedicineRetinal-Detachmentmedia_commonVistaLenses IntraocularVision BinocularDistanceHigh myopiaRetinal detachmentGeneral MedicineMiddle AgedQualityTreatment OutcomeOftalmologíaFemalemedicine.symptomPhotopic visionRiskmedia_common.quotation_subjectProsthesis DesignContrast Sensitivity03 medical and health sciencesHumansMonocularPhacoemulsificationbusiness.industryMultifocal Iolmedicine.diseaseeye diseasesVisual PerformanceOphthalmology030221 ophthalmology & optometryOptometrysense organsbusiness030217 neurology & neurosurgeryEuropean journal of ophthalmology
researchProduct

Direct costs of glaucoma and severity of the disease: a multinational long term study of resource utilisation in Europe

2005

International audience; Background: Resource utilisation and direct costs associated with glaucoma progression in Europe are unknown. As population progressively ages, the economic impact of the disease will increase. Methods: From a total of 1655 consecutive cases, the records of 194 patients were selected and stratified by disease severity. Record selection was based on diagnoses of primary open angle glaucoma, glaucoma suspect, ocular hypertension, or normal tension glaucoma; 5 years minimum follow up were required. Glaucoma severity was assessed using a six stage glaucoma staging system based on static threshold visual field parameters. Resource utilisation data were abstracted from the…

Maleage distributionOrganes des sensgenetic structuresOffice VisitsOcular hypertensionGlaucomaDiseaseintraocular hypertensionSeverity of Illness IndexIndirect costs0302 clinical medicineambulatory careNormal tension glaucomamiddle agedopen angle glaucoma80 and overMedicine030212 general & internal medicinepathophysiologystatistical significanceAged 80 and overeducation.field_of_studyadultdisease coursearticlehealth care costclinical trialHealth Care Costshealth care planningSensory Systems3. Good healthEuropeagedfemalepriority journalstatisticsHealth Resourcesdisease severityadult; aged; article; disease course; disease severity; Europe; female; follow up; general practitioner; glaucoma; health care cost; health care utilization; human; intraocular hypertension; major clinical study; male; medical record; open angle glaucoma; priority journal; statistical significance; visual field; age distribution; ambulatory care; clinical trial; drug cost; economics; health care planning; hospitalization; middle aged; multicenter study; pathophysiology; sex ratio; statistics; utilization review; Adult; Age Distribution; Aged; Aged 80 and over; Drug Costs; Europe; Female; Follow-Up Studies; Glaucoma; Health Care Costs; Health Resources; Humans; Male; Middle Aged; Office Visits; Severity of Illness Index; Sex Distribution; Visual Fieldshospitalizationvisual fieldWorld Viewsmedicine.medical_specialtyOpen angle glaucomadrug costPopulationSensory OrgansMédecine humaine et pathologiemedical recordDrug Costs03 medical and health sciencesCellular and Molecular Neurosciencehealth care utilizationSeverity of illnessfollow upHumanshumanSex Distribution[SDV.MHEP.OS]Life Sciences [q-bio]/Human health and pathology/Sensory Organseducationutilization reviewSettore MED/30 - Malattie Apparato Visivobusiness.industryGlaucomaeconomicssex ratiomedicine.diseasemajor clinical studyeye diseasesOphthalmologymulticenter studygeneral practitionerEmergency medicine030221 ophthalmology & optometryOptometryHuman health and pathologyVisual Fieldsbusiness[SDV.MHEP]Life Sciences [q-bio]/Human health and pathologyFollow-Up Studies
researchProduct

Contrast sensitivity after refractive lens exchange with a multifocal diffractive aspheric intraocular lens

2013

Purpose: To evaluate distance and near contrast sensitivity (CS) under photopic and mesopic conditions before and after refractive lens exchange (RLE) and implantation of the aspheric AcrySof ReSTOR (SN6AD3 model) intraocular lens (IOL) Methods: Sixty eyes of 30 consecutive patients after RLE underwent bilateral implantation with the aspheric AcrySof ReSTOR IOL. The patients sample was divided into myopic [n=15, mean spherical equivalent (SE) -6.87± 2.03 diopters (D)] and hyperopic (n=15, mean SE +4.52±1.14 D) groups. Monocular uncorrected visual acuity at distance and near (UCVA and UCNVA, respectively) and monocular best corrected visual acuity at distance and near (BCVA and BCNVA, respec…

Malegenetic structuresMesopic visionmedicine.medical_treatmentVisual AcuityIntraocular lensMyopia/surgerylaw.inventionLens Implantation Intraocularlcsh:OphthalmologylawMyopiaContrast (vision)Prospective StudiesDioptreMathematicsmedia_commonLenses Intraoculareducation.field_of_studyGeneral MedicineMiddle AgedFacoemulsificaciónLens (optics)HiperopiaHyperopiaFemalePhotopic visionmedicine.medical_specialtyMiopíaVisual acuitymedia_common.quotation_subjectPopulationCataract ExtractionContrast SensitivityVision MonocularOphthalmologyImplantación de lentes intraocularesmedicineHumansHyperopia/physiopathologyAgudeza visualeducationCristalinoAgedMonocularPhacoemulsificationDistance PerceptionLens cristalline/surgeryeye diseasesOphthalmologyLens implantation intraocularlcsh:RE1-994Optometrysense organs
researchProduct

Series of fibrinous inflammation after implantation of capsular tension rings

2014

Purpose To analyze the cause of fibrinous inflammation in eyes with capsular tension rings (CTRs) after cataract surgery. Setting Department of Ophthalmology, University Medical Center, Johannes Gutenberg-University Mainz, Mainz, Germany. Design Retrospective case series. Methods High-performance liquid chromatography was implemented to eliminate impurities. One CTR was explanted for microbiologic examination. The pH values of the CTR and the storage solution were analyzed, Seldi and Maldi tests were performed, as well as toxicity tests with immortal cell lines. Material batches were analyzed. The organic carbon content of CTRs, detergents, and storage solutions was checked. The presence of…

Malemedicine.medical_specialtyAfter cataractTopical treatmentMethylmethacrylatemedicine.disease_causeProsthesis ImplantationPostoperative ComplicationsLens Implantation IntraocularOphthalmologymedicineHumansUniversity medicalDevice RemovalAgedRetrospective StudiesAged 80 and overEndophthalmitisFibrinPhacoemulsificationAmoebocyte lysatebusiness.industrySmear testsFibrinous inflammationProstheses and ImplantsMiddle AgedSensory SystemsSurgeryOphthalmologyMethacrylatesFemaleSurgeryIrritationbusinessJournal of Cataract and Refractive Surgery
researchProduct