Search results for " Ion"
showing 10 items of 2482 documents
Fluence effect on ion-implanted As diffusion in relaxed SiGe
2005
A systematic study on the fluence (5 × 108 − 4 × 1014 cm−2) dependence of ion-implanted As diffusion in relaxed Si1 − xGex alloys (with x = 0.2, 0.35 and 0.5) and silicon has been performed by the modified radiotracer and secondary ion mass spectrometry techniques. With fluences above 4 × 1011 cm−2 a clear fluence-dependent enhancement in arsenic diffusion was noted for Si1 − xGex. In case of arsenic-implanted silicon such fluence dependency was not observed. This can be assigned to enhanced implantation-induced damage formation and more deficient radiation damage recovery of SiGe.
Crystalline phase detection in glass ceramics by EPR spectroscopy
2018
The advances of EPR spectroscopy for the detection of activators as well as determining their local structure in the crystalline phase of glass ceramics is considered. The feasibility of d-element (Mn2+, Cu2+) and f-element (Gd3+, Eu2+) ion probes for the investigation of glass ceramics is discussed. In the case of Mn2+, the information is obtained from the EPR spectrum superhyperfine structure, for Gd3+ and Eu2+ probes – from the EPR spectrum fine structure, whereas for Cu2+ ions the changes in the EPR spectrum shape could be useful. The examples of EPR spectra of the above-mentioned probes in oxyfluoride glass ceramics are illustrated. ----/ / /---- This is the preprint version of the fol…
The effect of cavity tuning on oxygen beam currents of an A-ECR type 14 GHz electron cyclotron resonance ion source.
2016
The efficiency of the microwave-plasma coupling plays a significant role in the production of highly charged ion beams with electron cyclotron resonance ion sources (ECRISs). The coupling properties are affected by the mechanical design of the ion source plasma chamber and microwave launching system, as well as damping of the microwave electric field by the plasma. Several experiments attempting to optimize the microwave-plasma coupling characteristics by fine-tuning the frequency of the injected microwaves have been conducted with varying degrees of success. The inherent difficulty in interpretation of the frequency tuning results is that the effects of microwave coupling system and the ca…
Kinetic instabilities in pulsed operation mode of a 14 GHz electron cyclotron resonance ion source
2016
The occurrence of kinetic plasma instabilities is studied in pulsed operation mode of a 14 GHz Aelectron cyclotron resonance type electron cyclotron resonance ion source. It is shown that the temporal delay between the plasma breakdown and the appearance of the instabilities is on the order of 10- 100 ms. The most important parameters affecting the delay are magnetic field strength and neutral gas pressure. It is demonstrated that kinetic instabilities limit the high charge state ion beam production in the unstable operating regime. peerReviewed
Photoelectron Emission from Metal Surfaces Induced by Radiation Emitted by a 14 GHz Electron Cyclotron Resonance Ion Source
2015
Photoelectron emission measurements have been performed using a room-temperature 14 GHz ECR ion source. It is shown that the photoelectron emission from Al, Cu, and stainless steel (SAE 304) surfaces, which are common plasma chamber materials, is predominantly caused by radiation emitted from plasma with energies between 8 eV and 1 keV. Characteristic X-ray emission and bremsstrahlung from plasma have a negligible contribution to the photoelectron emission. It is estimated from the measured data that the maximum conceivable photoelectron flux from plasma chamber walls is on the order of 10% of the estimated total electron losses from the plasma. peerReviewed
New progress of high current gasdynamic ion source (invited).
2016
The experimental and theoretical research carried out at the Institute of Applied Physics resulted in development of a new type of electron cyclotron resonance ion sources (ECRISs)—the gasdynamic ECRIS. The gasdynamic ECRIS features a confinement mechanism in a magnetic trap that is different from Geller’s ECRIS confinement, i.e., the quasi-gasdynamic one similar to that in fusion mirror traps. Experimental studies of gasdynamic ECRIS were performed at Simple Mirror Ion Source (SMIS) 37 facility. The plasma was created by 37.5 and 75 GHz gyrotron radiation with power up to 100 kW. High frequency microwaves allowed to create and sustain plasma with significant density (up to 8 × 1013 cm−3 ) …
Annealing behaviour of aluminium-implanted InP
2000
The annealing behaviour of aluminium has been studied in single-crystal InP implanted with 40 and 120 keV 27Al+ ions. The implantation doses were 1 x 1015 and 1 x 1016 cm-2. The aluminium concentration profiles were determined by two techniques, Secondary ion mass spectrometry (SIMS) and the nuclear resonance broadening technique (NRB) which was used for checking purposes. The usability of the SIMS technique for profiling Al rich layers was studied. Significant inconsistencies were observed in the SIMS profiles with the high dose implanted samples. The 120 keV, 1 x 1016 cm-2 implanted samples were subject to annealing in argon atmosphere in the temperature range 380–600°C. Redistribution an…
Accumulation of radiation defects and modification of micromechanical properties under MgO crystal irradiation with swift 132Xe ions
2020
This work has been carried out within the framework of the EUROfusion Consortium and has received funding from the Euratom research and training programme 2014-2018 and 2019-2020 under grant agreement No. 633053. The views and opinions expressed herein do not necessarily reflect those of the European Commission. A.A. also acknowledges support via the project GF AP05134257 of Ministry of Education and Science of the Republic of Kazakhstan .
Thermal annealing of radiation damage produced by swift 132Xe ions in MgO single crystals
2020
Abstract The annealing kinetics of the electron-type F+ and F color centers in highly pure MgO single crystals irradiated by 0.23-GeV 132Xe ions with fluences covering three orders of magnitude (Φ = 5 × 1011 –3.3 × 1014 ions/cm2) are studied experimentally via dependence of the optical absorption on preheating temperature. The annealing data are analyzed in terms of the diffusion-controlled bimolecular reactions between F-type centers and complementary interstitial oxygen ions. The behavior of the main kinetic parameters – the migration energies and pre-exponential factors – for different irradiation fluences is discussed and compared with that for other wide-gap binary materials from previ…
Depth profiles of damage creation and hardening in MgO irradiated with GeV heavy ions
2019
This work has been performed within the framework of the EUROfusion Enabling Research project: ENR-MFE19.ISSP-UL-02 “Advanced experimental and theoretical analysis of defect evolution and structural disordering in optical and dielectric materials for fusion applications”. The views and opinions expressed herein do not necessarily reflect those of the European Commission.