Search results for " Limit"

showing 10 items of 1716 documents

Isotope selective ultratrace analysis of plutonium by resonance ionisation mass spectrometry

2006

Abstract Resonance ionisation mass spectrometry (RIMS) is a sensitive and selective method for isotopically resolved ultratrace analysis of long-lived radionuclides. For the routine analysis of plutonium three titanium–sapphire lasers pumped by a pulsed Nd:YAG laser in combination with a time-of-flight mass spectrometer are used. The detection limit of this system is as low as 106–107 atoms for the plutonium isotopes 238Pu to 244Pu. The RIMS technique was applied to investigate the isotopic composition and the content of plutonium in a depleted uranium penetrator as used during the Balkan conflict delivering important information on the origin of the depleted uranium in this type of ammunit…

Detection limitRadionuclideIsotopeRadiochemistryAnalytical chemistryResonancechemistry.chemical_elementMass spectrometryPlutoniumIsotope separationlaw.inventionchemistrylawDepleted uranium
researchProduct

Oxidation of adrenaline and noradrenaline by solved molecular oxygen in a FIA assembly.

2002

A simple and effective procedure is proposed for the study and simultaneous determination of adrenaline and noradrenaline. The fluorimetric determination of both substances is performed in a flow injection assembly and by oxidation of both drugs with the solved molecular oxygen. The influence of different parameters is empirically studied and the interpretation of the reaction mechanism is also added. The determination of adrenaline is monitored at 450 nm and the outputs at 520 nm correspond to the adrenaline and noradrenaline global amount; for both lectures lambda(exc) 329 nm. The influence of temperature is relevant and analytical determination occurred at 55 degrees C by immersing the s…

Detection limitReaction mechanismChromatographyEpinephrineChemistryClinical BiochemistryAnalytical chemistryFluorescence spectrometryPharmaceutical ScienceFluorescence spectroscopyAnalytical ChemistryOxygenNorepinephrineLinear rangeDrug DiscoveryFlow Injection AnalysisFluorometryMolecular oxygenQuantitative analysis (chemistry)Oxidation-ReductionSpectroscopyAnalysis methodJournal of pharmaceutical and biomedical analysis
researchProduct

FI automatic method for the determination of copper(II) based on coproporphyrin I-Cu(II)/TCPO/H(2)O(2) chemiluminescence reaction for the screening o…

2004

Abstract In this paper, an automatic method for the screening of water samples containing Cu(II) was proposed, based on peryoxalate chemiluminescence reaction using coproporphyrin I as fluorophor compound to provide selectivity and a simple flow injection (FI) chemiluminescence detector (CLD). FI system conditions were chosen in order to distinguish samples over or under legislation limit established (50 μg l−1) with high reliability. The detection limit found was 9 μg l−1 and the linear dynamic range was 15–125 μg l−1 of Cu(II). Repeatibility and reproducibility studies gave good precision and accuracy with recovery near 100%. Under these conditions, the method resulted selective and only …

Detection limitReproducibilityAccuracy and precisionChemistryAnalytical chemistrychemistry.chemical_elementCopperAnalytical Chemistrylaw.inventionchemistry.chemical_compoundlawTCPOSelectivityHydrogen peroxideChemiluminescenceTalanta
researchProduct

Selective and sentivive method based on capillary liquid chromatography with in-tube solid phase microextraction for determination of monochloramine …

2015

Abstract Due to the difficulties of working with chloramines, a critical examination of monochloramine standard preparation has been performed in order to select the best synthesis conditions. The analyte has been determined by in-tube solid phase extraction coupled to capillary liquid chromatography with UV detection (IT-SPME Capillary LC DAD). Potential factors affecting the response of monochloramine such as the pH of mobile phase and the volume of sample processed by IT-SPME Capillary LC DAD have been investigated and optimized. According to the results of the study, 0.1 mL or 4.0 mL of sample at neutral pH were loaded in the chromatographic system. A sensitive and selective method has …

Detection limitReproducibilityAnalyteChloramineChromatographyCapillary actionChloraminesOrganic ChemistryAnalytical chemistryElectrophoresis CapillaryWaterGeneral MedicineSolid-phase microextractionBiochemistryAnalytical Chemistrychemistry.chemical_compoundLinear rangechemistryLimit of DetectionSolid phase extractionSolid Phase MicroextractionWater Pollutants ChemicalChromatography LiquidJournal of Chromatography A
researchProduct

Sensitive determination of methylenedioxylated amphetamines by liquid chromatography.

2001

Different strategies for the liquid chromatographic determination of methylenedioxylated amphetamines were evaluated: separation and detection of underivatized analytes by (i) UV or (ii) fluorescence, (iii) derivatization with 3,5-dinitrobenzoyl chloride followed by separation and UV detection of the derivatives formed and (iv) derivatization with 9-fluorenylmethyl chloroformate (FMOC) and subsequent separation and fluorimetric detection of the derivatives. The compounds tested were 3,4-methylenedioxyamphetamine (MDA), 3,4-methylenedioxymethamphetamine (MDMA) and 3,4-methylenedioxyethylamphetamine (MDE). On the basis of these studies, a new procedure for the chromatographic determination of…

Detection limitReproducibilityAnalyteChromatographyChemistryN-Methyl-34-methylenedioxyamphetamineAmphetaminesChloroformateBiochemistryFluorescence spectroscopyAnalytical Chemistrychemistry.chemical_compoundElectrochemistryHallucinogensEnvironmental ChemistryHumansUv detectionDerivatizationQuantitative analysis (chemistry)Spectroscopy34-MethylenedioxyamphetamineChromatography LiquidThe Analyst
researchProduct

Derivatization techniques for automated chromatographic analysis of amphetamine usingo-phthaldialdehyde: A comparative study

2000

The potential of different chromatographic systems for automated, on-line analysis of amphetamine in biological fluids is illustrated. The various systems integrate analyte purification and enrichment, separation, derivatization in different derivatization modes witho-phthaldialdehyde (OPA) and N-acetyl-L-cysteine (NAC), and fluorimetric detection. The reliability of the systems has been tested by analysing urine and plasma samples containing amphetamine in the 0.1–20.0 μg mL−1 range. Pre, on and post-column derivatization strategies are compared in terms of their instrumental requirements, selectivity, sensitivity, linearity and reproducibility.

Detection limitReproducibilityAnalyteChromatographyOrganic ChemistryClinical BiochemistryBiochemistryHigh-performance liquid chromatographyAnalytical Chemistrychemistry.chemical_compoundchemistrymedicineSample preparationAmphetamineDerivatizationQuantitative analysis (chemistry)medicine.drugChromatographia
researchProduct

Automated trace enrichment for screening and/or determination of primary, secondary and tertiary amphetamines in biological samples by liquid chromat…

1999

A rapid and simple liquid chromatographic method for the automated determination of amphetamines in biological fluids was developed. The proposed procedure is based on the injection of 250 microL of sample into a 20 x 2.1 mm id precolumn (packed with a 30 microns Hypersil C18 stationary phase) for enrichment and purification of the analytes. Next, the analytes are transferred to a 5 microns LiChrospher 100 RP18, 125 x 4 mm id analytical column for their separation under reversed-phase conditions. Water was used to eliminate the matrix components from the precolumn and a 0.2 M phosphate buffer (pH 3) containing 2% triethylamine was the mobile phase for the resolution of the amphetamines. The…

Detection limitReproducibilityAnalyteChromatographyResolution (mass spectrometry)AmphetaminesReproducibility of ResultsPseudoephedrineBiochemistrySensitivity and SpecificityAnalytical ChemistryMatrix (chemical analysis)chemistry.chemical_compoundchemistryElectrochemistrymedicineEnvironmental ChemistryHumansEphedrineTriethylamineSpectroscopymedicine.drugChromatography LiquidThe Analyst
researchProduct

Photo-induced chemiluminescence determination of the pesticide Buminafos by a Multicommutation flow-analysis assembly

2008

Abstract The preliminary experiments in this paper deal with the photo-induced chemiluminescent behaviour of Buminafos family, after the experimental screening tests and several of them resulted positive, the herbicide Buminafos was selected to develop a new analytical method. The determination of Buminafos was performed with the aid of a Multicommutation (a solenoid valve set) assembly. The method involves the on-line photo-degradation of the analyte (stopped flow, 5 s) with the selected suitable medium (0.05% hydrogen peroxide) and its subsequent chemiluminescent oxidation by the potassium permanganate. Sample solution alternated segments with the photo-degradation medium; and, after the …

Detection limitReproducibilityAnalyteChromatographyScreening testAnalytical chemistryPesticideAnalytical Chemistrylaw.inventionchemistry.chemical_compoundPotassium permanganatechemistrylawHydrogen peroxideChemiluminescenceTalanta
researchProduct

Spectrophotometric determination of mercury(II) and silver(I) with copper(II) and diethyldithiocarbamate in the presence of triton X-100

1986

Abstract Procedures for the determination of mercury and silver by displacement of diethyldithiocarbamate (DDTC) from its copper complex in the presence of 1% Triton X-100, and measurement of the decrease in the Cu(DDTC) 2 absorbance, are described. The use of the surfactant avoids the need for an extraction step. Reproducibility within 1% and detection limits of 0.25 ppm Hg(II) and 0.45 ppm Ag(I) have been obtained, and linear calibration ranges up to 13 ppm Hg(II) and 15 ppm Ag(I). In the presence of 0.1 M EDTA very good selectivity is achieved.

Detection limitReproducibilityAnalytical chemistrychemistry.chemical_elementCopperAnalytical ChemistryMercury (element)Absorbancechemistry.chemical_compoundPulmonary surfactantchemistryTriton X-100SelectivityNuclear chemistryTalanta
researchProduct

Photo-induced chemiluminescence-based determination of diphenamid by using a multicommuted flow system

2007

This manuscript deals with the application of molecular connectivity calculations to predict the photo-induced chemiluminescent behaviour of the family of herbicides grouped as amides. Several compounds of this group were theoretically studied by means of a general discriminant equation formerly obtained, being 18 of them (plus eight from the chloroacetanilide sub-group) predicted with a high probability as photo-induced chemiluminescent. Empirical confirmation of the chemiluminometric behaviour was performed with some few commercially available amide herbicides. On the basis of these results, a new multicommutation-photo-chemiluminescent method is proposed for the determination of the diph…

Detection limitReproducibilityChromatographyChemistryAnalytical chemistryRepeatabilityAnalytical Chemistrylaw.inventionchemistry.chemical_compoundSodium hydroxidelawAmideCalibrationPhotodegradationChemiluminescenceTalanta
researchProduct