Search results for " MIR"

showing 10 items of 304 documents

Dicer and drosha expression and response to bevacizumab-based therapy in advanced colorectal cancer patients.

2013

PURPOSE: The miRNA-regulating enzymes Dicer and Drosha exhibit aberrant expression in several cancer types. Dicer and Drosha play a crucial role during the angiogenetic process in vitro and, for Dicer, in vivo. We aimed to investigate the potential role of Dicer and Drosha in predicting response to Bevacizumab-based therapy in advanced colorectal cancer (CRC) patients. METHODS: Dicer and Drosha mRNA levels were analysed in formalin-fixed paraffin-embedded specimens from patients affected by advanced CRC treated with or without Bevacizumab-containing regimens (n=116 and n=50, respectively) and from patients with diverticulosis as control group (n=20). The experimental data were obtained usin…

MaleRibonuclease IIICancer ResearchSettore MED/06 - Oncologia Medicagenetic processesAngiogenesis InhibitorsKaplan-Meier EstimateDEAD-box RNA HelicasesangiogenesisIntestinal MucosaOligonucleotide Array Sequence AnalysisAged 80 and overReverse Transcriptase Polymerase Chain Reactionfood and beveragesMiddle AgedPrognosisImmunohistochemistryCRCBevacizumabGene Expression Regulation NeoplasticqPCRTreatment OutcomeOncologyMonoclonalImmunohistochemistryFemaleColorectal Neoplasmsmedicine.drugAdultBevacizumabBiologyAntibodies Monoclonal HumanizedDroshaYoung AdultSDG 3 - Good Health and Well-beingmicroRNAmedicineHumansDroshamiRNAAgedGene Expression ProfilingfungiCancermedicine.diseaseGene expression profilingenzymes and coenzymes (carbohydrates)miRNA; angiogenesisMultivariate AnalysisCancer researchbiology.proteinBevacizumab; CRC; Dicer; Drosha; miRNAs; qPCRDicerDicer
researchProduct

Deregulation of dicer and mir-155 expression in liposarcoma

2015

Liposarcoma (LPS) is the most common soft tissue sarcoma. It has been demonstrated that mir-155 was the most overexpressed miRNA in well-differentiated LPS(WDLPS)/dedifferentiated LPS (DDLPS). The aim of this study is to evaluate the involvement of Dicer, Drosha and mir-155 in development of LPS and their possible role in stratification of different histological subtypes. Dicer, Drosha and mir-155 mRNA levels were analyzed in formalin-fixed paraffin-embedded specimens from patients diagnosed with 62 LPS and compared with samples of adipose tissues of healthy donors. The experimental data were obtained using qRT-PCR comparing Dicer, Drosha and mir-155 expression levels in tumor samples versu…

MaleRibonuclease IIIPathologymedicine.medical_specialtyDEAD-box RNA Helicases -- biosynthesis -- genetics -- metabolismSettore MED/06 - Oncologia MedicaMicroRNAs -- biosynthesis -- geneticsAdipose tissueLiposarcomaRibonuclease III -- biosynthesis -- genetics -- metabolismDroshamiR-155DEAD-box RNA Helicasemir-155DEAD-box RNA HelicasesRetrospective StudiemicroRNAmedicineHumansMicroarray AnalysiDroshaRetrospective StudiesbiologySoft tissue sarcomaAnatomical pathologyMicroRNALiposarcomaSciences bio-médicales et agricolesmedicine.diseaseMicroarray AnalysisLiposarcoma -- genetics -- metabolism -- pathologyDicer; Drosha; liposarcoma; mir-155; DEAD-box RNA Helicases; Female; Humans; Liposarcoma; Male; MicroRNAs; Microarray Analysis; Retrospective Studies; Ribonuclease IIIMicroRNAsOncologyliposarcomabiology.proteinlipids (amino acids peptides and proteins)FemaleClinical Research PaperDicerDicer; Drosha; Liposarcoma; Mir-155; DEAD-box RNA Helicases; Female; Humans; Liposarcoma; Male; MicroRNAs; Microarray Analysis; Retrospective Studies; Ribonuclease III; OncologyHumanDicer
researchProduct

Micro-RNA in pancreatic adenocarcinoma: Predictive/prognostic biomarkers or therapeutic targets?

2015

Pancreatic ductal adenocarcinoma (PDAC) is a tumor with a poor prognosis, short overall survival and few chemotherapeutic choices. MicroRNAs (miRNAs) are non-coding, single-stranded RNAs of around 22 nucleotides involved in the pathogenic mechanisms of carcinogenesis and metastasis. They have been studied in many tumors in order to identify potential diagnostic, prognostic or therapeutic targets. In the current literature, many studies have analyzed the role of miRNAs in PDAC. In fact, the absence of appropriate biomarkers, the difficultly of early detection of this tumor, and the lack of effective chemotherapy in patients with unresectable disease have focused attention on miRNAs as new, i…

Maleendocrine system diseasesPrognosiSettore MED/06 - Oncologia MedicaMice NudeReviewDiseaseAdenocarcinomaMalignancymedicine.disease_causeMetastasisMicemicroRNABiomarkers TumorCarcinomamedicineAnimalsHumansmiRNAbiomarkers; miRNAs; pancreatic adenocarcinoma; prognosis; therapyAnimalbusiness.industryPancreatic NeoplasmbiomarkersMicroRNABiomarkerPrognosismedicine.diseasePhenotypedigestive system diseasesPancreatic NeoplasmsGene Expression Regulation NeoplasticMicroRNAsPhenotypeBiomarkers; miRNAs; Pancreatic adenocarcinoma; Prognosis; Therapy; Adenocarcinoma; Animals; Biomarkers Tumor; Carcinoma Pancreatic Ductal; Female; Gene Expression Regulation Neoplastic; Humans; Male; Mice; Mice Nude; MicroRNAs; Pancreatic Neoplasms; Phenotype; Prognosis; OncologyOncologymiRNAsImmunologyCancer researchAdenocarcinomaFemaleTherapybusinessCarcinogenesisPancreatic adenocarcinomaCarcinoma Pancreatic DuctalHuman
researchProduct

A High Throughput, Minimally Invasive, Ultrasound Guided Model for the Study of Catheter Associated Urinary Tract Infections and Device Encrustation …

2014

Purpose Catheter associated urinary tract infections are one of the most common health care associated infections. The condition is frequently complicated by encrustation, which blocks the catheter lumen. Preclinical research is limited by the lack of relevant high throughput and cost-effective animal models. Current models are restricted to female mice, associated with major transurethral loss of catheter materials during micturition, highly invasive and complex. We present an ultrasound guided, minimally invasive model that enables catheter associated urinary tract infection and catheter encrustation studies in each mouse gender. Materials and Methods Catheter segments (4 mm) were implant…

Malemedicine.medical_specialtyPercutaneousUrologyUrinary systemmedia_common.quotation_subjectLumen (anatomy)UrinationMiceAnimalsMedicineSeldinger techniqueProteus mirabilisUltrasonographymedia_commonUrinary bladderbusiness.industryUltrasoundSurgeryDisease Models AnimalCathetermedicine.anatomical_structureCatheter-Related InfectionsUrinary Tract InfectionsFemaleProteus InfectionsUrinary CatheterizationbusinessJournal of Urology
researchProduct

Robot passes the mirror test by inner speech

2021

Abstract The mirror test is a well-known task in Robotics. The existing strategies are based on kinesthetic-visual matching techniques and manipulate perceptual and motion data. The proposed work attempts to demonstrate that it is possible to implement a robust robotic self-recognition method by the inner speech, i.e. the self-dialogue that enables reasoning on symbolic information. The robot self-talks and conceptually reasons on the symbolic forms of signals, and infers if the robot it sees in the mirror is itself or not. The idea is supported by the existing literature in psychology, where the importance of inner speech in self-reflection and self-concept emergence for solving the mirror…

Matching (statistics)business.industryComputer scienceGeneral Mathematicsmedia_common.quotation_subjectRoboticsCognitive architectureInner speech Cognitive architecture Robot mirror test Conceptual reasoningMotion (physics)Computer Science ApplicationsTask (project management)Control and Systems EngineeringPerceptionRobotComputer visionArtificial intelligencebusinessMirror testSoftwaremedia_common
researchProduct

Microcavity Light Emitting Diodes Based on GaN membranes Grown by Molecular Beam Epitaxy on Silicon

2003

Resonant-cavity InGaN/GaN quantum well light emitting diodes have been fabricated. Nitride layers were grown by molecular beam epitaxy on Si (111). We fabricated the structures using a combination of Si substrate etching, GaN etching and dielectric (Ta2O5/SiO2) mirror deposition. The electroluminescence spectra show that the emission within the distributed Bragg reflector stop band is enhanced in the membrane microcavity. The cavity modes are broadened by some cavity length non-uniformity that is introduced when the GaN is back etched to adjust the cavity length. This process does not need any transfer on an intermediate host substrate and is fully compatible with large area semiconductor p…

Materials sciencePhysics and Astronomy (miscellaneous)Physics::Instrumentation and DetectorsGeneral Physics and AstronomyPhysics::OpticsGallium nitrideSubstrate (electronics)Light emitting diodeFILMSSettore ING-INF/01 - Elettronicalaw.inventionchemistry.chemical_compoundCondensed Matter::Materials ScienceOpticsEtching (microfabrication)lawDielectric mirrorDielectric mirrorQuantum wellbusiness.industryGeneral EngineeringMembraneGallium nitrideDistributed Bragg reflectorlight emitting diodesComputer Science::OtherchemistryOptoelectronicsWAVELASERbusinessMicrocavityMolecular beam epitaxyLight-emitting diodeMolecular beam epitaxySAPPHIRE
researchProduct

CMOS Photodiode Design for Gamma Camera Application

2008

We designed new photodiodes sensors including current mirror amplifiers. These photodiodes have been fabricated using a CMOS 0.6 micrometers process from Austria Micro System (AMS). The photodiode areas are respectively 1 mm × 1 mm and 0.4 mm × 0.4 mm with fill factor 98% and total chip area is 2 square millimetres. The sensor pixels show a logarithmic response in illumination and are capable of detecting very low blue light (less than 0.5 lux) . These results allow to use our sensor in new gamma camera solid-state concept.

Materials sciencePixelbusiness.industryAmplifierPhotodetectorChiplaw.inventionPhotodiodeCurrent mirrorCMOSlawOptoelectronicsbusinessGamma camera2008 IEEE International Conference on Signal Image Technology and Internet Based Systems
researchProduct

Realization and drive tests of active thin glass x-ray mirrors

2016

A technique to obtain lightweight and high-resolution focusing mirror segments for large aperture X-ray telescopes is the hot slumping of thin glass foils. In this approach, already successfully experimented to manufacture the optics of the NuSTAR X-ray telescope, thin glasses are formed at high temperature onto a precisely figured mould. The formed glass foils are subsequently stacked onto a stiff backplane with a common axis and focus to form an XOU (X-ray Optical Unit), to be later integrated in the telescope optic structure. In this process, the low thickness of the glass foils guarantees a low specific mass and a very low obstruction of the effective area. However, thin glasses are sub…

Materials sciencebusiness.industryAntenna apertureActive opticsX-ray telescopePiezoelectricitySettore ING-INF/01 - Elettronicalaw.inventionTelescopeOpticsSettore FIS/05 - Astronomia E AstrofisicalawAngular resolutionFocus (optics)ActuatorbusinessX-ray mirrors active optics thin glass mirrors piezoelectric actuators
researchProduct

Combined heat and power generation with a HCPV system at 2000 suns

2015

In the framework of the FAE “Fotovoltaico ad Alta Efficienza” (“High Efficiency Photovoltaic”) Research Project funded by the Sicilian Region under the program PO FESR Sicilia 2007/2013 4.1.1.1, we have developed an innovative solar CHP system for the combined production of heat and power at the high concentration level of 2000 suns [1]. This work shows the experimental results obtained on FAE-HCPV modules and analyses the behaviour of the system. The solar radiation is concentrated on commercial InGaP/InGaAs/Ge triple-junction solar cells designed for intensive work. The primary optics is a rectangular off-axis parabolic mirror (with a size of 46x46 = 2116 cm2 in a projection normal to the…

Materials sciencebusiness.industryInGaP/InGaAs/Ge triple-junction solar cellHeat sinkSolar energySolar mirrorSolar cell efficiencyElectricity generationOpticsreflactive opticsHeat transferConcentrating PhotovoltaicOptoelectronicsbusinessElectrical efficiencyThermal energy
researchProduct

Focusing System for a Non-Normal Incidence Pumped, Sub-10 nm TCE XRL

2008

An extended ray-tracing study of the main pumping pulse (MP) focusing optics was made in order to develop a transient collisionally excited (TCE) x-ray laser (XRL) set-up for sub 10 nm wavelength by using non-normal incidence pumping. The study takes into account limitations determined by the large beam dimensions of the high energy MP. A setup using two off-the-shelf spherical mirrors is proposed, corresponding to a possible realization at the PHELIX laser facility.

Materials sciencebusiness.industryPhysics::OpticsCurved mirrorPhelixLaserPulse (physics)law.inventionWavelengthOpticslawExcited stateTransient (oscillation)businessBeam (structure)
researchProduct