Digital performance improvements of a CdTe pixel detector for high flux energy-resolved X-ray imaging

2015

Abstract Photon counting detectors with energy resolving capabilities are desired for high flux X-ray imaging. In this work, we present the performance of a pixelated Schottky Al/p-CdTe/Pt detector (4×4) coupled to a custom-designed digital readout electronics for high flux measurements. The detector (4×4×2 mm 3 ) has an anode layout based on an array of 16 pixels with a geometric pitch of 1 mm (pixel size of 0.6 mm). The 4-channel readout electronics is able to continuously digitize and process the signals from each pixel, performing multi-parameter analysis (event arrival time, pulse shape, pulse height, pulse time width, etc.) even at high fluxes and at different throughput and energy re…

PhysicsNuclear and High Energy PhysicsPixelPhysics::Instrumentation and Detectorsbusiness.industryEnergy-resolved photon counting detectorSettore FIS/01 - Fisica SperimentaleDetectorSchottky diodePixel detectorSettore FIS/07 - Fisica Applicata(Beni Culturali Ambientali Biol.e Medicin)Photon countingCharge sharingCdTe detectorHigh photon counting rateFull width at half maximumOpticsDigital pulse processingMonochromatic colorbusinessInstrumentationPulse shape analysiEnergy (signal processing)Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
researchProduct

Timing results using an FPGA-based TDC with large arrays of 144 SiPMs

2015

Silicon photomultipliers (SiPMs) have become an alternative to traditional tubes due to several features. However, their implementation to form large arrays is still a challenge especially due to their relatively high intrinsic noise, depending on the chosen readout. In this contribution, two modules composed of SiPMs with an area of roughly mm mm are used in coincidence. Coincidence resolving time (CRT) results with a field-programmable gate array, in combination with a time to digital converter, are shown as a function of both the sensor bias voltage and the digitizer threshold. The dependence of the CRT on the sensor matrix temperature, the amount of SiPM active area and the crystal type…

PhysicsNuclear and High Energy PhysicsPixelbusiness.industryDetectorBiasingNoise (electronics)Time-to-digital converterFull width at half maximumSilicon radiation detectorsSilicon photomultiplierOpticsNuclear Energy and EngineeringGate arrayPositron emission tomography (PET)Nuclear medicineTEORIA DE LA SEÑAL Y COMUNICACIONESElectronic engineeringTrigger circuitsElectrical and Electronic Engineeringbusiness
researchProduct

The EM imaging reconstruction method in γ-ray astronomy

1998

Abstract The simpler imaging reconstruction methods used for γ-ray coded mask telescopes are based on correlation methods, very fast and simple-to-use but with limitations in the reconstructed image. To improve these results, other reconstruction methods have been developed, such as the maximum entropy methods or the Iterative Removal Of Sources (IROS). However, such kind of methods are slower and can be impracticable for very complex telescopes. In this paper we present an alternative image reconstruction method, based on an iterative maximum likelihood algorithm called the EM algorithm, easy to implement and that can be successfully used for not very complex coded mask systems, as is the …

PhysicsNuclear and High Energy PhysicsPrinciple of maximum entropyComputingMethodologies_IMAGEPROCESSINGANDCOMPUTERVISIONAstrophysics::Instrumentation and Methods for AstrophysicsAstronomyComputerApplications_COMPUTERSINOTHERSYSTEMSIterative reconstructionReconstruction methodlaw.inventionTelescopeMaximum likelihood algorithmlawExpectation–maximization algorithmCorrelation methodReconstructed imageInstrumentationNuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms
researchProduct

Effects of scintillation light collection on the time resolution of a time-of-flight detector for annihilation quanta

1990

Monte Carlo methods were used to simulate the production and collection of scintillation light in a BaF/sub 2/ crystal. The calculated results were compared to measured values for detectors with different heights. Based on this simulation, a TOF (time-of-flight) detector consisting of two conical BaF/sub 2/ crystals (base radius 18 mm, top radius 15 mm, height 25 mm) was assembled. The total time resolution of this system was (210+or-5) ps FWHM (full width at half maximum) for 511-keV annihilation quanta and was found to be independent of the source position between the detectors. Since the time resolution of the TOF detector system consisting of two conical BaF/sub 2/ crystals is sufficien…

PhysicsNuclear and High Energy PhysicsScintillationAnnihilationTime of flight detectorPhysics::Instrumentation and Detectorsbusiness.industryDetectorMonte Carlo methodRadiusNuclear physicsFull width at half maximumOpticsNuclear Energy and EngineeringScintillation counterElectrical and Electronic EngineeringbusinessIEEE Transactions on Nuclear Science
researchProduct

Spectroscopic response of a CdZnTe multiple electrode detector

2007

Abstract The spectroscopic performances of a CdZnTe detector (crystal size: 5×5×0.9 mm 3 ) with five electrodes (cathode, anode and three steering electrodes) were studied. The anode layout, which consists of a circular electrode ( φ =80 μm) surrounded by two ring electrodes (gap=100 μm; radial width Δ r =100 μm) and by one electrode that extends to the edge of the crystal, is mostly sensitive to the electron carriers, overcoming the well known effect of the hole trapping in the measured spectra. We report on the spectroscopic response of the detector at different bias voltages of the electrodes and at various photon energies ( 109 Cd, 241 Am and 57 Co sources). The CdZnTe detector exhibits…

PhysicsNuclear and High Energy PhysicsSpectrometerbusiness.industryCdZnTe detectorSteering electrodeDetectorMultiple electrode detectorElectronSmall pixel effectCathodeAnodelaw.inventionCrystalFull width at half maximumX-ray and gamma ray spectroscopylawElectrodeOptoelectronicsbusinessInstrumentationNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
researchProduct

Experimental results from Al/p-CdTe/Pt X-ray detectors

2013

Abstract Recently, Al/CdTe/Pt detectors have been proposed for the development of high resolution X-ray spectrometers. Due to the low leakage currents, these detectors allow high electric fields and the pixellization of anodes with the possibility to realize single charge carrier sensing detectors. In this work, we report on the results of electrical and spectroscopic investigations on CdTe diode detectors with Al/CdTe/Pt electrode configuration (4.1×4.1×0.75 and 4.1×4.1×2 mm 3 ). The detectors are characterized by very low leakage currents in the reverse bias operation: 0.3 nA at 25 °C and 2.4 pA at −25 °C under a bias voltage of −1000 V. The spectroscopic performance of the detectors at b…

PhysicsNuclear and High Energy PhysicsSpectrometerbusiness.industryDetectorX-ray detectorBiasingPhoton countingFull width at half maximumElectric fieldOptoelectronicsCharge carrierbusinessInstrumentationNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
researchProduct

Longitudinal and transverse momentum distributions of 9Li fragments from break-up of 11Li

1995

7 pages, 3 figures, 1 table.

PhysicsNuclear and High Energy PhysicsTransverse planeFull width at half maximumMomentum (technical analysis)Break-UpSignificant differenceTransverse momentumSigmaHaloAtomic physicsNuclear Physics
researchProduct

Detector blockbased on arrays of 144 SiPMs and monolithic scintillators: A performane study

2015

[EN] We have developed a detector block composed by a monolithic LYSO scintillator coupled to a custom made 12 12 SiPMs array. The design is mainly focused to applications such as Positron Emission Tomography. The readout electronics is based on 3 identical and scalable Application Specific Integrated Circuits (ASIC). We have determined the main performance of the detector block namely spatial, energy, and time resolution but also the system capability to determine the photon depth of interaction, for different crystal surface treatments. Intrinsic detector spatial resolution values as good as 1.7 mm FWHM and energies of 15% for black painted crystals were measured. & 2014 Elsevier B.V. All…

PhysicsNuclear and High Energy Physicsmedicine.medical_specialtyPhotonPhysics::Instrumentation and Detectorsbusiness.industryASICDetectorSilicon photomultipliersScintillatorScintillator crystalFull width at half maximumSilicon photomultiplierApplication-specific integrated circuitmedicineOptoelectronicsMedical physicsbusinessMATEMATICA APLICADAInstrumentationImage resolutionPositron Emission TomographyBlock (data storage)
researchProduct

High-resolution positron lifetime spectrometer with BaF2 scintillators

1987

In this communication we report on a design of a fast coincidence positron lifetime spectrometer, which is based on single crystal barium fluoride (BaF2) scintillators. A good time resolution (190ps, FWHM), combined with a high efficiency, has been obtained in the normal experimental set-up (with cathode earthed in the photo multipliers). The pile-up effect is observed to disturbe the measured lifetimes in the 180 degree geometry due to the high detection efficiency of the BaF2 scintillator.

PhysicsPhysics and Astronomy (miscellaneous)SpectrometerPhysics::Instrumentation and Detectorsbusiness.industryBarium fluorideGeneral EngineeringGeneral ChemistryScintillatorCathodeCoincidencelaw.inventionchemistry.chemical_compoundFull width at half maximumPositronOpticschemistrylawGeneral Materials SciencebusinessSingle crystalApplied Physics A Solids and Surfaces
researchProduct

Improving the performance of CdZnTe detectors using infrared stimulation

2011

The influence of monochromatic optical stimulation with wavelengths from 400 nm to 1100 on characteristics of the CdZnTe quasi-hemispherical detectors was studied. It was found that illumination with infrared (IR) light of wavelengths (870–900 nm) close to the absorption edge of the CdZnTe significantly improves the detectors performance at room temperature. Improvement can be achieved with low-intensity IR illumination of about 1–10 µW. The higher intensity illumination leads to degradation of the detector spectrometric characteristics. Infrared radiation penetrates into the detector sensitive volume, change the balance equilibrium between free and trapped carriers, leading to improve char…

PhysicsPhysics::Instrumentation and Detectorsbusiness.industryInfraredDetectorTemperature measurementlaw.inventionWavelengthFull width at half maximumOpticsAbsorption edgelawOptoelectronicsMonochromatic colorbusinessAstrophysics::Galaxy AstrophysicsLight-emitting diode2011 IEEE Nuclear Science Symposium Conference Record
researchProduct