Enantioresolution in electrokinetic chromatography-complete filling technique using sulfated gamma-cyclodextrin. Software-free topological anticipati…
2016
Few papers have tried to predict the resolution ability of chiral selectors in capillary electrophoresis for the separation of the enantiomers of chiral compounds. In a previous work, we have used molecular information available on-line to establish enantioresolution levels of basic compounds using highly sulfated β-CD (HS-β-CD) as chiral selector in electrokinetic chromatography-complete filling technique (EKC-CFT). The present study is a continuation of this previous work, introducing some novelties. In this work, the ability of sulfated γ-cyclodextrin (S-γ-CD) as chiral selector in EKC-CFT is modelled for the first time. Thirty-three structurally unrelated cationic and neutral compounds …
Potential of human serum albumin as chiral selector of basic drugs in affinity electrokinetic chromatography-partial filling technique
2006
The enantiomeric resolution of compounds using HSA by means of affinity EKC (AEKC)-partial filling technique is the result of a delicate balance between different experimental variables such as protein concentration, running pH (background electrophoretic buffer (BGE), protein, and compound solutions), and plug length. In this paper, the possibility of using HSA as chiral selector for enantioseparation of 28 basic drugs using this methodology is studied. The effect of the physicochemical parameters, the structural properties of compounds, and compound-HSA protein binding percentages over their chiral resolution with HSA is outlined. Based on the results obtained, a decision tree is proposed…
Synthesis of spherical porous silicas in the micron and submicron size range: challenges and opportunities for miniaturized high-resolution chromatog…
2000
Classical silica technology has reached its limit with respect to an ultimate minimum particle size of about 2 microm in diameter. Here, a novel process is presented which allows one to synthesize porous silica beads and control their particle diameter in situ, within the range of 0.2-2.0 microm. As a result, no sizing is required and losses of silica are avoided. Furthermore, the process enables one to control in situ the pore structural parameters and the surface chemistry of the silica beads. Even though surface funtionalized silicas made according to this process can principally be applied in fast HPLC the column pressure drop will be high even for short columns. In addition, the column…
Evaluation and comparison of tailor-made stationary phases based on spherical silica-based beads for capillary electrochromatography via peptide sepa…
2004
Small cyclic peptides have been employed to elucidate the performance of novel sorbents as stationary phases in capillary electrochromatography (CEC). In this paper chain length dependencies for ordinary liquid chromatographic sorbents are reported together with findings acquired on beads specifically designed to suit CEC. The latter, tailor-made, spherical, porous silica exhibits a distinguished surface modification to meet the criteria anticipated to enhance performance profiles in CEC. With well-characterised peptides resembling the analytes, probing of the CEC system in a systematic manner (predominantly via the organic modifier content of the background electrolyte (BE)) reveals insigh…
Life-time studies with capillary electrochromatography columns operated under different conditions.
2000
A test system has been established to permit the monitoring of the life-time performance of several reversed- phase capillary electrochromatography (CEC) columns. The retention factors, k(cec), peak symmetry coefficients, lambda(sym), and column efficiencies, N, of three neutral n-alkylbenzene analytes, namely ethyl-, n-butyl- and n-pentylbenzenes, were determined for Hypersil 3 microm n-octylsilica and n-octadecylsilica packed into CEC capillary columns of 100 microm I.D., with a packed length of 250 mm, and a total length of 335 mm. The performances of these CEC capillary columns were examined for a variety of eluents with pH values ranging between pH 2.0 - 8.0, similar to those employed …
Capillary electrochromatography analysis of hormonal cyclic and linear peptides.
2001
The retention behavior of linear and cyclic peptides has been studied by capillary electrochromatography (CEC) with a variety of different n-alkyl silica reversed-phase sorbents and also with mixed-mode phases containing both strong cation-exchange (sulfonic acid) and n-alkyl groups bonded onto the silica surface, using eluents ranging from pH 2.0 to pH 5.0. Depending upon the amino acid sequence, electrochromatographic retention of the peptides was strongly affected by the composition of the eluent, its pH value, and the choice of sorbent packed into the capillaries. The dominant separation processes operating with these charged analytes could be modulated inter alia by the content of orga…
Discontinuous electrokinetic chromatography of parabens using different substituted resonances as pseudostationary phases
1999
Resorcarene derivatives, negatively charged even at moderate pH, were synthesized and employed as pseudostationary phases to achieve mobilities exceeding that of the electroosmotic flow. Under these conditions, a discontinuous electrolyte system was developed which allows the separation of four uncharged homologous 4-hydroxybenzoic esters (parabens) within a zone of resorcarene electrolyte, and the detection of these UV active compounds in a resorcarene-free zone, free from the high UV background absorbance of the resorcarenes. Resorcarenes, with differently charged functionalities (carboxylate and phosphate groups) to provide the electrophoretic mobility and with alkyl residues of differen…
Determination of cationic surfactants by capillary zone electrophoresis and micellar electrokinetic chromatography with deoxycholate micelles in the …
2000
Mixtures of the cationic surfactants benzalkonium chloride (BKC) and cetylpyridinium chloride (CPC) were quickly resolved and reproducibly and reliably determined by using background electrolytes (BGEs) containing 80 mM borate, pH 8.5, bile salts and large concentrations of an organic solvent. When the bile salt is present, the separation mechanism changes from capillary zone electrophoresis (CZE) to a mixed micellar electrokinetic chromatography (MEKC)-CZE, with predominant MEKC interactions, which lead to an excellent resolution of all the solutes, including the C12-C18 homologues of BKC and CPC. A BGE containing 50 mM sodium deoxycholate and 30% ethanol for an extreme resolution, or 20% …
Fast determination of prominent carotenoids in tomato fruits by CEC using methacrylate ester-based monolithic columns.
2007
In this study, the major carotenoids (beta-carotene and lycopene) present in tomato fruits were analyzed by CEC with a methacrylate ester-based monolithic column. The effects of the porogenic solvent ratio, and the hydrophobicity of bulk monomer employed were examined on carotenoids separations. A fast separation of these analytes was achieved in less than 5.0 min in a mobile phase containing 35% THF, 30% ACN, 30% methanol, and 5% of a 5 mM Tris aqueous buffer, pH 8, with lauryl methacrylate-based monoliths. The CEC method was evaluated in terms of detection limit and reproducibility (retention time, area, and column preparation) with values below 1.6 microg/mL and 7.2%, respectively. The p…
Determination of major carotenoids in vegetables by capillary electrochromatography.
2006
A simple and rapid method for the isocratic separation and determination of carotenoids (carotenes and xanthophylls) in vegetables by CEC is described. The capillary column (100 microm ID, 25 cm effective length) was packed with 3 microm Hypersil ODS particles. The optimized mobile phase contained 60% ACN, 35% THF and 5% of a 5 mM Tris aqueous buffer of pH 8. beta-Carotene, lycopene and lutein were separated with efficiencies of 66 000-128 000 plates/m within a short time (less than 12 min for the last peak eluted, 13/13'-cis-beta-carotene). An excellent resolution of the three carotenoids, as well as partial resolution of their geometrical isomers, was achieved. Application to the determin…