Traction test of temporary dental cements
2017
Background Classic self-curing temporary cements obstruct the translucence of provisional restorations. New dual-cure esthetic temporary cements need investigation and comparison with classic cements to ensure that they are equally retentive and provide adequate translucence. The objective is to analyze by means of traction testing in a in vitro study the retention of five temporary cements. Material and methods Ten molars were prepared and ten provisional resin restorations were fabricated using CAD-CAM technology (n=10). Five temporary cements were selected: self-curing temporary cements, Dycal (D), Temp Bond (TB), Temp Bond Non Eugenol (TBNE); dual-curing esthetic cements Temp Bond Clear…
Screw‐in‐screw fixation of fragility sacrum fractures provides high stability without loosening—biomechanical evaluation of a new concept
2020
Surgical treatment of fragility sacrum fractures with percutaneous sacroiliac (SI) screw fixation is associated with high failure rates. Turn-out is detected in up to 20% of the patients. The aim of this study was to evaluate a new screw-in-screw implant prototype for fragility sacrum fracture fixation. Twenty-seven artificial hemipelvises were assigned to three groups (n = 9) for instrumentation of an SI screw, the new screw-in-screw implant prototype, ora transsacral screw. Before implantation, a vertical osteotomy was set in zone 1 after Denis. All specimens were biomechanically tested to failure in upright position. Validated setup and test protocol were used for complex axial and torsi…
Improving the cementation of the tibial component in knee arthroplasty : a study of four techniques in the cadaver.
2021
Aims The main objective of this study is to analyze the penetration of bone cement in four different full cementation techniques of the tibial tray. Methods In order to determine the best tibial tray cementation technique, we applied cement to 40 cryopreserved donor tibiae by four different techniques: 1) double-layer cementation of the tibial component and tibial bone with bone restrictor; 2) metallic cementation of the tibial component without bone restrictor; 3) bone cementation of the tibia with bone restrictor; and 4) superficial bone cementation of the tibia and metallic keel cementation of the tibial component without bone restrictor. We performed CT exams of all 40 subjects, and mea…
Novel Digital Technique to Quantify the Area and Volume of Cement Remaining and Enamel Removed after Fixed Multibracket Appliance Therapy Debonding: …
2020
The aim of this study was to construct a novel, repeatable, reproducible, and accurate measurement protocol for the area and volume of the remaining cement after removal of fixed multibracket appliances, the area and volume of remaining cement after cement removal, the area and volume of enamel removed after cement removal, and the volume of cement used to adhere fixed multibracket appliances. A total of 30 brackets were cemented and removed with over 30 extracted teeth embedded into three experimental models of epoxy resin. The models were scanned before and after bracket placement, bracket debonding, and polishing the remaining cement. The brackets were submitted to micro-computed tomogra…
CRT-727 Percutaneous Balloon Atrial Septostomy for Direct Left Heart Decompression in Patients on Extra Corporeal Membrane Oxygenation
2014
Severe myocardial dysfunction and added afterload from the Extra Corporeal Membrane Oxygenation (ECMO) arterial cannula may lead to significant rise in left ventricular (LV) end-diastolic and left atrial (LA) pressures. This may result in ischemia, lower likelihood of ventricular recovery and hence
Anterior dislocation in a total knee arthroplasty: A case report and literature review.
2015
Dislocations of a total knee arthroplasty (TKA) are an uncommon injury and only few cases of anterior dislocations have been reported. We report a rare case of anterior dislocation of a 10-year-old posterior stabilized total knee arthroplasty in a 74-year-old woman. The patient was successfully treated by close reduction of the dislocation followed by immobilization in full extension with a long leg cast. Because of a high risk of neurovascular complications, a high index of suspicion for vascular injury must be maintained. For this reason, a proper diagnosis is required and immediate reduction is recommended.
Coronary Stent Strut Fractures: Classification, Prevalence and Clinical Associations
2021
Introduction. The frequency, characteristics and clinical implications of Strut fractures (SFs) remain incompletely understood. Methods and results. A total of 185 (160 patients) newer-generation drug-eluting stents (DES) were imaged. SFs were found in 21 DES (11.4%) and were classified in four patterns: one single stacked strut (41%)
The effect of cement fixation on initial micromotion of the femoral component in condylar knee replacement
1992
Four fresh, cadaveric specimens were fitted with total knee replacements and mounted on a knee joint loading and measuring rig. Femoral component micromotion in the sagittal plane was measured with a transducer during flexion and extension of the specimen. Various condylar designs were used without and with cement. Movement followed a characteristic curve pattern and was less with cement fixation particularly for bone of low trabecular strength as determined by bone sample tests for stiffness. Cement fixation appears to be superior to cementless fixation.
Differences in Accuracy and Radiation Dose in Placement of Iliosacral Screws: Comparison between 3D and 2D Fluoroscopy
2022
Percutaneous iliosacral screw fixation is a widely accepted method of stabilizing the posterior pelvic ring. Recently developed tools such as 3D-navigated fluoroscopy and computed navigation seem to prevent a surgeon from conducting screw misplacement. The study aimed to comparatively assess the introduction of sacroiliac screw placement using 2D and 3D fluoroscopy in terms of accuracy and radiation exposure. Iliosacral screws were introduced in 37 patients using 2D (group N1) and in 36 patients using 3D fluoroscopy (group N2) techniques. Overall, 61 and 56 screws were introduced in groups N1 and N2, respectively. Screw placement accuracy was assessed using postoperative computed tomography…
Safety of hospital discharge before return of bowel function after elective colorectal surgery
2020
Ileus is common after colorectal surgery and is associated with an increased risk of postoperative complications. Identifying features of normal bowel recovery and the appropriateness for hospital discharge is challenging. This study explored the safety of hospital discharge before the return of bowel function.A prospective, multicentre cohort study was undertaken across an international collaborative network. Adult patients undergoing elective colorectal resection between January and April 2018 were included. The main outcome of interest was readmission to hospital within 30 days of surgery. The impact of discharge timing according to the return of bowel function was explored using multiva…