Search results for " PLASMA"

showing 10 items of 2522 documents

Nuclear anapole moment interaction in BaF from relativistic coupled-cluster theory

2018

We present high accuracy relativistic coupled cluster calculations of the P-odd interaction coefficient $W_A$ describing the nuclear anapole moment effect on the molecular electronic structure. The molecule under study, BaF, is considered a promising candidate for the measurement of the nuclear anapole moment, and the preparation for the experiment is now underway [Altunas et al., Phys. Rev. Lett. 120, 142501 (2018)]. Influence of various computational parameters (size of the basis set, treatment of relativistic effects, and treatment of electron correlation) on the calculated $W_A$ coefficient is investigated and a recommended value of 147.7 Hz with an estimated uncertainty of 1.5% is prop…

ATOMIC PARITY NONCONSERVATIONDIATOMIC-MOLECULESP-ODDVIOLATIONAtomic Physics (physics.atom-ph)Nuclear TheoryDENSITY FUNCTIONALSFOS: Physical sciences01 natural sciences010305 fluids & plasmasPhysics - Atomic PhysicsENHANCEMENTMolecular electronic structure0103 physical sciencesIMPLEMENTATIONNuclear Experiment010306 general physicsBasis setPhysicsElectronic correlationELECTRIC-FIELD GRADIENTSDiatomic moleculeWEAK-INTERACTIONSCoupled clusterMoment (physics)Atomic physicsRelativistic quantum chemistryAPPROXIMATIONPhysical Review A
researchProduct

On the variations of acoustic absorption peak with particle velocity in micro-perforated panels at high level of excitation.

2010

The acoustic behavior of micro-perforated panels (MPP) is studied theoretically and experimentally at high level of pressure excitation. A model based on Forcheimer's regime of flow velocity in the perforations is proposed. This model is valid at relatively high Reynolds numbers and low Mach numbers. The experimental method consists in measuring the acoustical pressure at three different positions in an impedance tube, the two measurement positions usually considered in an impedance tube and one measurement in the vicinity of the rear surface of the MPP. The impedance tube is equipped with a pressure driver instead of the usual loudspeaker and capable of delivering a high sound pressure lev…

Absorption (acoustics)Materials scienceAcoustics and UltrasonicsAcoustics[ PHYS.COND.CM-MS ] Physics [physics]/Condensed Matter [cond-mat]/Materials Science [cond-mat.mtrl-sci]FOS: Physical sciencesPhysics - Classical PhysicsPolypropylenes01 natural sciences010305 fluids & plasmasAbsorption[SPI]Engineering Sciences [physics]symbols.namesakeMotionArts and Humanities (miscellaneous)0103 physical sciencesPressureParticle velocitySound pressure010301 acoustics[ PHYS.MECA.ACOU ] Physics [physics]/Mechanics [physics]/Acoustics [physics.class-ph][SPI.ACOU]Engineering Sciences [physics]/Acoustics [physics.class-ph][ SPI.ACOU ] Engineering Sciences [physics]/Acoustics [physics.class-ph]Construction MaterialsAirFluid Dynamics (physics.flu-dyn)Classical Physics (physics.class-ph)Reynolds numberPhysics - Fluid DynamicsAcousticsModels TheoreticalSound intensity[PHYS.MECA.ACOU]Physics [physics]/Mechanics [physics]/Acoustics [physics.class-ph]Mach numberFlow velocityNonlinear DynamicsSteelFacility Design and Construction[PHYS.COND.CM-MS]Physics [physics]/Condensed Matter [cond-mat]/Materials Science [cond-mat.mtrl-sci]symbolsLinear ModelsAcoustic impedanceNoisePorosityThe Journal of the Acoustical Society of America
researchProduct

Highly efficient isotope separation and ion implantation of  163Ho for the ECHo project

2019

Abstract The effective electron neutrino mass measurement in the framework of the ECHo experiment requires radiochemically pure 163 Ho, which is ion implanted into detector absorbers. To meet the project specifications in efficiency and purity, the entire process chain of ionization, isotope separation , and implantation of 163Ho was optimized. A new two-step resonant laser ionization scheme was established at the 30 kV magnetic mass separator RISIKO. For ionization and separation, an average efficiency of 69 ( 5 )  stat(4)sys% was achieved using intra-cavity frequency doubled Ti:sapphire lasers. The implantation of undesired 166 m Ho, which is present in trace amounts in the initial  163Ho…

Accelerator Physics (physics.acc-ph)PhysicsNuclear and High Energy PhysicsAtomic Physics (physics.atom-ph)Orders of magnitude (temperature)DetectorAnalytical chemistryFOS: Physical sciencesLaser01 natural sciencesPhysics - Atomic Physics010305 fluids & plasmasIsotope separationlaw.inventionIonIon implantationlawIonization0103 physical sciencesSapphirePhysics - Accelerator Physics010306 general physicsInstrumentationNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
researchProduct

A comparative study on sample preparation procedures for supplementary foods by ICP-OES: Green chemistry considerations

2015

An inductively coupled plasma optical emission (ICP-OES) method was developed for the simultaneous determination of major, minor and trace elements in food. Preliminary studies focused on selecting suitable operational conditions in order to provide the highest sensitivity and to maximize the number of analytes to be determined without spectral or matrix interference. Ruthenium and rhenium were evaluated as internal standards and samples were analyzed at different dilution levels. Furthermore, a comparative study was carried out by using three sample digestion methods, microwave-assisted digestion with HNO3/H2O2, dry ashing and dry ashing with Mg(NO3)2/MgO as an ashing aid. Adequate precisi…

Accuracy and precisionAnalyteChromatographyChemistryGeneral Chemical EngineeringGeneral EngineeringAnalytical chemistryAnalytical ChemistryDilutionCertified reference materialsAshingInductively coupled plasma atomic emission spectroscopySample preparationInductively coupled plasmaAnalytical Methods
researchProduct

Producing SI-traceable reference values for Cd, Cr and Pb amount contents in polyethylene samples from the Polymer Elemental Reference Material (PERM…

2000

The present paper describes the certification of the amount content of Cd, Cr and Pb in two different polyethylene materials within the third phase of the Polyethylene Elemental Reference Material (PERM) project. The analytical procedure to establish the reference values for Cd, Cr and Pb amount contents in these materials is based on isotope dilution mass spectrometry used as a primary method of measurement. Cd and Pb were measured with inductively coupled plasma-mass spectrometry and Cr with positive thermal ionization-mass spectrometry. The decomposition of the polymer matrix was carried out using a high pressure asher. Reference values for amount content, traceable to the SI-system, hav…

Accuracy and precisionGeneral Chemical EngineeringAnalytical chemistrychemistry.chemical_elementGeneral ChemistryIsotope dilutionPolyethyleneMass spectrometryMatrix (chemical analysis)Chromiumchemistry.chemical_compoundThird phasechemistrySafety Risk Reliability and QualityInstrumentationInductively coupled plasma mass spectrometryAccreditation and Quality Assurance
researchProduct

230Th/U-dating of a late Holocene low uranium speleothem from Cuba

2010

We present 22 U-series ages for a stalagmite from north-western Cuba based on multi-collector inductively coupled plasma mass spectrometry (MC-ICPMS) and thermal ionisation mass spectrometry (TIMS). Our results reveal that the stalagmite continuously grew within the last ~1400a. Low uranium content of the sample and thus, extremely low 230Th concentrations limit the precision and accuracy of 230Th/U-dating by TIMS. Samples measured by MC-ICPMS show a high variability of 232Th content along the growth axis with some sections significantly affected by initial 230Th from a detrital phase. An a-priori bulk earth ratio for (238U/232Th) cannot be used to accurately account for this initial 230Th.…

Accuracy and precisiongeographygeography.geographical_feature_categoryMineralogyThermal ionizationSpeleothemchemistry.chemical_elementStalagmiteUraniumMass spectrometrychemistryInductively coupled plasma mass spectrometryGeologyHoloceneIOP Conference Series: Earth and Environmental Science
researchProduct

Room temperature acid sonication ICP-MS multielemental analysis of milk

2005

Abstract Room temperature acid sonication of milk samples is proposed as a fast alternative methodology for the determination of the total content of 45 elements (Li, Al, Ti, V, Cr, Mn, Fe, Co, Ni, Cu, Zn, As, Se, Rb, Sr, Y, Mo, Ag, Cd, In, Sn, U, Sb, Te, Cs, Ba, Hg, Pb, Bi, Th, La, Ce, Pr, Nd, Sm, Eu, Gd, Dy, Ho, Er, Tm, Yb, Lu, Hf and Ta) in milk by inductively coupled plasma mass spectrometry (ICP-MS). The aforementioned procedure involves a 10 min sample pre-treatment. Measurements were made in quantitative and semiquantitative (Totalquant ® ) modes of analysis using Rh as internal standard and Be, Ge, Tb and Re for internal calibration of the equipment in the semiquantitative mode. The…

Acid digestionIsotopeChemistrySonicationPolyatomic ionAnalytical chemistryMass spectrometryBiochemistryAnalytical ChemistryEnvironmental ChemistryIsobaric processDirect analysisInductively coupled plasma mass spectrometrySpectroscopyAnalytica Chimica Acta
researchProduct

Dependence of plasma pH on oxygen saturation

1969

Abstract The influence of haemoglobin oxygenation on the pH value of the blood plasma of healthy adolescents was investigated at 38°C by varying the parameters CO2 pressure, Hb concentration and buffer bases. A total of 5000 measurements gave the following results: 1. 1. The pHs difference between oxygenated and deoxygenated blood increases with diminishing CO2 pressure and with increasing Hb concentration. There is a linear relation between the pHs changes and the O2 saturation of the haemoglobin. 2. 2. Quantitatively these relationships can be expressed by the following equation: δpHs = (8 − pH ox − log 0.03 Pco 2 ) · [Hb] 225 · (100 − So 2 100 where ΔpHs is the pHs difference between par…

Acid-Base EquilibriumPulmonary and Respiratory MedicineAdolescentPhysiologyChemistryPartial PressureAnalytical chemistryOxygenationVenous bloodPlasmaBuffersCarbon DioxideHydrogen-Ion ConcentrationOxygenBicarbonatesHemoglobinsBloodBiochemistryBlood plasmaLinear relationHumansBase excessOxygen saturationBlood phRespiration Physiology
researchProduct

The modelling of the cathode sheath of an electrical arc in vacuum

2003

This paper presents a simple model of the fragment in the cathode electrical arc root taking into account the physical phenomena occuring on the cathode surface and the sheath. The goal is the obtainment of characteristics values of the heat flux, the electrons, and atoms density in the sheath. Computation is carried out on a one-dimensional model with a coupling between the equation obtained in the sheath and an enthalpy model of the cathode to describe the temperature evolution. In the modelling, we introduce a friction zone above the sheath edge to characterize the heavy particle interactions. Numerical simulation shows that the ionic friction phenomenon deriving from ion–atom collision …

Acoustics and UltrasonicsvacuumIonic bondingarc rootheat fluxElectroncathode sheatharc01 natural sciences010305 fluids & plasmaslaw.inventionElectric arcCross section (physics)lawPhysics::Plasma Physics[PHYS.PHYS.PHYS-PLASM-PH]Physics [physics]/Physics [physics]/Plasma Physics [physics.plasm-ph]0103 physical sciences010306 general physicsCouplingComputer simulationChemistryMechanics[ PHYS.PHYS.PHYS-PLASM-PH ] Physics [physics]/Physics [physics]/Plasma Physics [physics.plasm-ph]Condensed Matter PhysicsCathodeSurfaces Coatings and FilmsElectronic Optical and Magnetic MaterialsHeat flux
researchProduct

Application of LA-ICP-MS as a rapid tool for analysis of elemental impurities in active pharmaceutical ingredients.

2014

The control of inorganic contaminants in active pharmaceutical ingredients has a significant role in the quality control of drug products. The concentration limits for metal residues in drug products have been defined by various regulatory guidelines. Laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) is a powerful and fast analytical technique for multi-elemental analysis. A disadvantage in using LA-ICP-MS method is the lack of matrix reference materials for validation and calibration purposes. This article focuses on the handling strategy of laboratory-made matrix calibration standards for the quantification of elemental impurities in an active pharmaceutical ingredie…

Active ingredientChromatographyChemistryLaser ablation inductively coupled plasma mass spectrometryClinical BiochemistryAnalytical techniqueAnalytical chemistryPharmaceutical ScienceAnalytical ChemistryMatrix (chemical analysis)Pharmaceutical PreparationsLa icp msSpectrometry Mass Matrix-Assisted Laser Desorption-IonizationDrug DiscoveryCalibrationInorganic contaminantsElemental impuritiesDrug ContaminationSpectroscopyJournal of pharmaceutical and biomedical analysis
researchProduct