Search results for " Parti"
showing 10 items of 9465 documents
Risk Assessment of Electron Induced SEE during the JUICE Mission
2018
The SEE sensitivity of electronic devices to high energy electrons has been put in evidence experimentally. Several ground experiments have shown that electron induced SEE could occur in recent technologies. In the case of the JUICE mission, the expected electron environment is harsher than for Earth orbits. The impact of such electron fluxes on the embedded electronics was assessed in this work. The study focused on SRAM memories SEU sensitivity. Three different device references were tested under electrons, as well as under protons and heavy ions. The electron and the low energy proton direct ionization contributions to the total SEU rate have been studied in more detail.
A graphene-based neutral particle detector
2019
A neutral particle detector is presented, in which the traditionally used target material, indium tin oxide (ITO), is replaced by graphene. The graphene-based detector enables collinear photodetachment measurements at a significantly shorter wavelength of light down to 230 nm compared to ITO-based detectors, which are limited at 335 nm. Moreover, the background signal from the photoelectric effect is drastically reduced when using graphene. The graphene based detector, reaching 1.7 eV further into the UV energy range, allows increased possibilities for photodetachment studies of negatively charged atoms, molecules, and clusters.A neutral particle detector is presented, in which the traditio…
Silicon dosimeters based on Floating Gate Sensor: design, implementation and characterization
2020
A rad-hard monolithic dosimeter has been implemented and characterized in a standard 180 nm CMOS technology. The radiation sensor (C-sensor) is based on a Floating Gate (FG) MOS discharge principle. The output current is processed by a current-to-voltage (I/V) interface and then converted by a 5-bit flash ADC. The dosimeter is re-usable (FG can be recharged) and can detect a dose up to 1krad (Si) with a resolution of 30rad (Si) typical over temperature 0 to 85°C range. The ADC allows easy further signal processing for calibration and averaging, etc. The power consumption of C-sensor plus I/V interface is < 2mW from a 5 V power supply. The overall layout area is less than 0.25mm2. The Rad…
D0D0π+ mass distribution in the production of the Tcc exotic state
2021
Measurement of the branching fraction for ψ(3686)→ωKS0KS0
2021
α -nucleus optical potentials from chiral effective field theory NN interactions
2022
Contextuality-by-Default: A Brief Overview of Ideas, Concepts, and Terminology
2016
This paper is a brief overview of the concepts involved in measuring the degree of contextuality and detecting contextuality in systems of binary measurements of a finite number of objects. We discuss and clarify the main concepts and terminology of the theory called “contextuality-by-default,” and then discuss generalizations of the theory to arbitrary systems of arbitrary random variables.
Observation of theψ(1 D23)State ine+e−→π+π−γχc1at BESIII
2015
Dy159 Electron-Capture: A New Candidate for Neutrino Mass Determination
2021
On-line commissioning of SHIPTRAP
2006
Abstract The on-line commissioning of the Penning-trap mass spectrometer SHIPTRAP was successfully completed with a mass measurement of holmium and erbium radionuclides produced at SHIP. A large fraction of contaminant ions created in the stopping cell was identified to originate from the buffer-gas supply system. Using a liquid nitrogen cold trap they were reduced to a tolerable amount and mass measurements of Er 147 , Er 148 , and Ho 147 with relative uncertainties of about 1 × 1 0 − 6 were performed.