Search results for " Phase"

showing 10 items of 1862 documents

Ex situ investigations of MOCVD-grown gallium nitride nanowires using reflection high energy electron diffraction

2011

Vertically oriented nanowires (NWs) of single-crystalline wurtzite GaN have been fabricated on sapphire substrates, via metal organic chemical vapor deposition (MOCVD). We present ex situ investigations on orientation and structure of grown GaN nanowires on GaN(0001) surface using reflection high energy electron diffraction (RHEED). Both ordered and randomly oriented GaN crystalline structures have been detected.

Reflection high-energy electron diffractionMaterials sciencebusiness.industryNanowireGallium nitrideChemical vapor depositionCrystallographychemistry.chemical_compoundchemistryElectron diffractionSapphireOptoelectronicsMetalorganic vapour phase epitaxybusinessWurtzite crystal structureIOP Conference Series: Materials Science and Engineering
researchProduct

Phases transitions in complexe oxides with perovskite structure : case system (1-x)Na0,5Bi0,5TiO3 - xCaTiO3

2015

The solid solutions (1-x)Na0,5Bi0,5TiO3 (NBT) – xCaTiO3 (CT) were studied by X-ray diffraction, Raman spectroscopy, scanning electron microscopy, impedance spectroscopy and DSC. These materials have a perovskite crystalline structure. This study reveals not only the complexity but also the richness of physical phenomena in these compounds: phases transitions sequences, the Ca2+ effect on the physical-chemistry properties and the relation between dielectric properties and crystalline structure. Thereby, (1-x)NBT – xCT solid solutions (0 ≤ x ≤ 1.00) were synthesized by chemical solid route, then they were sintered by a particular procedure in order to avoid sodium and bismuth volatilization. …

Relaxor[CHIM.MATE] Chemical Sciences/Material chemistryDielectric5TiO3 (NBT) – xCaTiO3Phases transitionPerovskiteCa2+ dopingFerroélectriques[PHYS.PHYS.PHYS-CHEM-PH] Physics [physics]/Physics [physics]/Chemical Physics [physics.chem-ph]Solution solide (1-x)Na0Hystérésis thermique5Bi0Transitions de phasesThermal hysteresis5TiO3 (NBT) – xCaTiO3 (CT) solid solutionDiélectriques(1-x)Na0Dopant Ca2+FerroelectricPérovskiteRelaxeurs
researchProduct

Comparison of three solid-phase extraction processes in quantification of ciprofloxacin and enrofloxacin in pork meat

2012

Due to strong implications for food safety, control of fluoroquinolones residues in swine meat should be undertaken to verify compliance of the contamination levels with the maximum residue limits recently updated by Commission Regulation (EU) No. 37/2010 of 22 December 2009. Solid-phase extraction is widely used in antibiotic analysis in food of animal origin. In this study, the results of a comparative study using different types of solid-phase extraction columns, HLB, MCX, and MAX, for ciprofloxacin and enrofloxacin analysis, in pork meat, are presented. In addition, diverse sample treatments for defatting, precipitate proteins, eliminate cations, and increase the ionic strength, were us…

Residue (complex analysis)ChromatographyMaximum Residue Limitbusiness.industryChemistryExtraction (chemistry)Filtration and SeparationContaminationFood safetyDefattingAnalytical ChemistryEnrofloxacinmedicineSolid phase extractionbusinessmedicine.drugJournal of Separation Science
researchProduct

Analysis of pesticide residues in fruit and vegetables by matrix solid phase dispersion (MSPD) and different gas chromatography element-selective det…

1995

A comparison between different element selective detectors for the determination of organophosphorus and organochlorine pesticide residues, from fruit and vegetables, was performed by capillary GC with electron capture detector (ECD), nitrogen phosphorus detector (NPD), flame photometric detector (FPD) in the sulphur and phosphorus modes, and mass spectrometry detector (MSD) in selected ion monitoring (SIM) mode. Pesticides were extracted from the different foodstuffs by Matrix Solid Phase Dispersion (MSPD). Recoveries of 41–108 % with relative standard deviation of 2–14 % in the concentration range 0.5–10 μg L−1 were obtained in oranges, lemons, grapefruit, pears, plums, lettuces and tomat…

Residue (complex analysis)ChromatographyNitrogen–phosphorus detectorPesticide residueChemistryOrganic ChemistryClinical BiochemistryAnalytical chemistryBiochemistryAnalytical ChemistryMatrix (chemical analysis)Electron capture detectorSelected ion monitoringGas chromatographySolid phase extractionChromatographia
researchProduct

Evaluation of a solid-phase extraction system for determining pesticide residues in milk.

1993

Abstract A simple and rapid procedure based on reversed solid-phase extraction with octadecylsilica was developed for determining chlorinated pesticide residues in milk. The need for an agent that breaks the fat globules was first investigated and the method variables were optimized on whole homogenized milk (3.6% fat content). Recovery experiments performed for 26 organochlorine pesticides at levels of 3–40 μg/l gave > 80% recoveries for all the compounds. The method was validated and evaluated by comparison with two widely used liquid-liquid extraction methods. The performance was checked by analysis of a certified standard with natural low endogenous levels (CMR 187) and different kinds …

Residue (complex analysis)InsecticidesChromatographyChromatography GasPesticide residueFat contentChemistryOrganic ChemistryExtraction (chemistry)Pesticide ResiduesTemperatureGeneral MedicinePesticideBiochemistryAnalytical ChemistryMilkHydrocarbons ChlorinatedSolventsAnimalsIndicators and ReagentsSolid phase extractionGlobules of fatGas chromatographyDairy ProductsJournal of chromatography
researchProduct

Rugged Large Volume Injection for Sensitive Capillary LC-MS Environmental Monitoring

2017

A rugged and high throughput capillary column (cLC) LC-MS switching platform using large volume injection and on-line automatic filtration and filter back-flush (AFFL) solid phase extraction (SPE) for analysis of environmental water samples with minimal sample preparation is presented. Although narrow columns and on-line sample preparation are used in the platform, high ruggedness is achieved e.g. injection of 100 non-filtrated water samples would did not result in a pressure rise/clogging of the SPE/capillary columns (inner diameter 300 µm). In addition, satisfactory retention time stability and chromatographic resolution were also features of the system. The potential of the platform for …

Resolution (mass spectrometry)Capillary actionAnalytical chemistry02 engineering and technologycapillary LC01 natural scienceslaw.inventionlcsh:ChemistrylawLiquid chromatography–mass spectrometrySample preparationSolid phase extractionon-line solid phase extractionFiltrationOriginal ResearchDetection limitChromatographyChemistry010401 analytical chemistryGeneral ChemistryRepeatability021001 nanoscience & nanotechnology0104 chemical sciencespharmaceutical productsChemistrylcsh:QD1-999column switchinglarge volume injection0210 nano-technologyFrontiers in Chemistry
researchProduct

Comparative modelling study on enantioresolution of structurally unrelated compounds with amylose-based chiral stationary phases in reversed phase li…

2020

[EN] Polysaccharide-based chiral stationary phases (CSPs) are the most used chiral selectors in HPLC. These CSPs can be used in normal, polar organic and aqueous-organic mobile phases. However, normal and polar organic mobile phases are not adequate for chiral separation of polar compounds, for the analysis of aqueous samples and for MS detection. In these situations, reversed phase conditions, without the usual non-volatile additives incompatible with MS detection, are preferable. Moreover, in most of the reported chiral chromatographic methods, retention is too large for routine work. In this paper, the chiral separation of 53 structurally unrelated compounds is studied using three commer…

Resolution (mass spectrometry)Reversed phase liquid hromatography010402 general chemistryMass spectrometry01 natural sciencesBiochemistryHigh-performance liquid chromatographyAmylose-based chiral stationary phasesMass SpectrometryAnalytical Chemistrychemistry.chemical_compoundAmylosePhase (matter)Least-Squares AnalysisAcetonitrileEnantioresolution modelling and descriptionChromatography High Pressure LiquidChromatography Reverse-PhaseAqueous solutionChromatography010401 analytical chemistryOrganic ChemistryDiscriminant partial least squaresStereoisomerismGeneral MedicineReversed-phase chromatography0104 chemical sciencesModels ChemicalchemistryFeature selectionRegression AnalysisAmyloseJournal of Chromatography A
researchProduct

The Nature of Rest Silanol Groups on the Surfaces of Silica Based Solid Phase Extraction Materials

2013

Author's version of an article in the journal: Advanced Materials Research. Also available from the publisher at: http://dx.doi.org/10.4028/www.scientific.net/AMR.650.66 Chemically bonded solid phase materials are very important in separation chemistry. The chemically modified silica gel contains rest silanol groups that can affect the retention properties when they are used for separation of compounds. Some commercially available solid phase extraction (SPE) materials based on silica gel were analysed for rest silanol groups by near infrared spectroscopy. The combination frequency of the water molecules in the 5500- 5000 cm -1 region was used in identifying the nature of water molecules on…

Rest (physics)VDP::Mathematics and natural science: 400::Chemistry: 440near infrared spectroscopyVDP::Technology: 500::Chemical engineering: 560Chemistrysolid phase extractionGeneral EngineeringAnalytical chemistryAdvanced materialssecond derivative profilesSilanolchemistry.chemical_compoundChemical engineeringsilanol groupsEndcappingSolid phase extractionAdvanced Materials Research
researchProduct

A BADER’S TOPOLOGICAL APPROACH FOR THE CHARACTERIZATION OF PRESSURE INDUCED PHASE TRANSITIONS

2012

Ringwoodite Bader analysis Phase transitions topology
researchProduct

Comparative Study of the Initial Experience in Performing Robotic and Laparoscopic Right Hepatectomy with Technical Description of the Robotic Techni…

2017

<b><i>Background:</i></b> Despite potential benefits of robotic liver surgery, it is still considered a “development in progress” technique. <b><i>Methods:</i></b> The outcomes of 14 patients undergoing robotic right hepatectomy were analyzed and compared with the results of 20 laparoscopic right hepatectomies consecutively performed by the same young surgeon. <b><i>Results:</i></b> The overall mean operative time was less in robotic arm (425 ± 139 vs. 565.18 ± 183.73, <i>p</i> = 0.022) and the estimated blood loss was similar (335.15 ± 139.8 vs. 423.95 ± 205.15, <i>p</i> = 0.17); no blood transf…

Robotic Surgical ProcedureSurgical marginmedicine.medical_specialtyBlood transfusionmedicine.medical_treatment030230 surgery03 medical and health sciences0302 clinical medicineRobotic Surgical ProceduresBlood lossRetrospective StudiemedicineHumansHepatectomyRobotic surgeryRight HepatectomyRetrospective Studiesbusiness.industryMortality rateLiver NeoplasmsGastroenterologyRobotic surgerySurgical techniqueSurgeryFeasibility StudieLiver Neoplasm030220 oncology & carcinogenesisInitial phaseFeasibility StudiesLaparoscopySurgeryClinical CompetenceHepatectomybusinessRobotic armLearning CurveHumanDigestive Surgery
researchProduct