Search results for " RAD"
showing 10 items of 7082 documents
Conditioning effect of transcranial magnetic stimulation evoking motor‐evoked potential on V‐wave response
2014
Abstract The aim of this study was to examine the collision responsible for the volitional V‐wave evoked by supramaximal electrical stimulation of the motor nerve during voluntary contraction. V‐wave was conditioned by transcranial magnetic stimulation (TMS) over the motor cortex at several inter‐stimuli intervals (ISI) during weak voluntary plantar flexions (n = 10) and at rest for flexor carpi radialis muscle (FCR; n = 6). Conditioning stimulations were induced by TMS with intensity eliciting maximal motor‐evoked potential (MEPmax). ISIs used were ranging from −20 to +20 msec depending on muscles tested. The results showed that, for triceps surae muscles, conditioning TMS increased the V‐…
Evaluation of atrial function by 2D strain echocardiography in patients with atrial fibrillation
2012
Abstract Objectives To evaluate atrial function by 2D strain in patients with atrial fibrillation (AF) and normal or slightly increased atrial size and to verify whether lower atrial strain is associated with more frequent AF recurrences. Materials and methods We studied 50 patients with AF, mean age 59.6 ± 13 years and 50 age-and gender-matched controls. We analyzed left atrial function through 2Dstrain imaging, after the re-establishment of sinus rhythm (SR) and we investigated about the recurrences of the arrhythmia. Results Atrial strain (AS) was lower in AF patients vs controls (LA p Conclusions The assessment of atrial function by strain imaging might help to identify patients who nee…
Practical recommendations for the application of DE 59/2013
2019
The changes introduced with Council Directive 2013/59/Euratom will require European Member States adapt their regulations, procedures and equipment to the new high standards of radiation safety. These new requirements will have an impact, in particular, on the radiology community (including medical physics experts) and on industry. Relevant changes include new definitions, a new dose limit for the eye lens, non-medical imaging exposures, procedures in asymptomatic individuals, the use and regular review of diagnostic reference levels (including interventional procedures), dosimetric information in imaging systems and its transfer to the examination report, new requirements on responsibiliti…
The role of PET radiomic features in prostate cancer: a systematic review
2021
Aim: This systematic review aims to present the available evidence on the use of radiomic features (RFs) extracted from PET imaging in patients with prostate cancer (PCa). Materials and methods: A comprehensive literature search of studies on the utility of PET-derived RFs in patients with PCa was performed in the PubMed/MEDLINE database through February 24th, 2021 using the following search string: [“positron-emission tomography” (MeSh terms) OR “positron emission tomography computed tomography” (MeSh terms) OR “positron-emission tomography” (all fields) OR “positron emission tomography computed tomography” (all fields) OR “PET” (all fields)] AND [“radiomics” (all fields) OR “radiomic” (al…
Synthesis and in vitro evaluation of (S)-2-([11C]methoxy)-4-[3-methyl-1-(2-piperidine-1-yl-phenyl)-butyl-carbamoyl]-benzoic acid ([11C]methoxy-repagl…
2004
The 11 C-labeled sulfonylurea receptor 1 (SUR1) ligand (S)-2-(( 11 C)methoxy)-4-(3-methyl-1-(2-piperidine-1-yl-phenyl)- butyl-carbamoyl)-benzoic acid (( 11 C)methoxy-repaglinide) was synthesized in an overall radiochemical yield of 35% after 55 min with a radiochemical purity higher than 99%. This compound is considered for the noninvasive investigation of the SUR1 receptor status of pancreatic b-cells by positron emission tomography (PET) in the context of type 1 and type 2 diabetes. The specific activity was 40-70 GBq/lmol. In vitro testing of the nonradioactive methoxy-repaglinide was performed to characterize the affinity for binding to the human SUR1 isoform. Methoxy-repaglinide induce…
Técnicas reconstructivas tras amputación abdominoperineal extraelevadora del recto o exenteración pélvica: mallas, plastias y colgajos
2014
Perineal wound complications after abdomino-perineal rectal resection are frequent and clinically relevant for their impact on the length of hospitalization, costs, patients' quality of life and oncologic results. With the diffusion of the preoperative radiotherapy and the gradual shift to the extra-elevator technique, the perineal morbidity rate has increased. Many series describing different techniques of primary closure of the perineal defect have been published, but high-quality clinical studies, indicating which is the best option, are missing. A biologic mesh, associated if possible to an omentoplasty, seems to be sufficient to close the perineal defect after extra-elevator abdomino-p…
Prognostic value of cardiac CT
2020
In the past decades, coronary computed tomography angiography (CCTA) has become a powerful tool in the management of coronary artery disease. The diagnostic and prognostic value of CCTA has been extensively demonstrated in both large observational studies and clinical trials among stable chest pain patients. The quantification of coronary artery calcium score (CACS) is a well-established predictor of cardiovascular morbidity and mortality in asymptomatic subjects. Besides CACS, the main strength of CCTA is the accurate assessment of the individual total atherosclerotic plaque burden, which holds important prognostic information. In addition, CCTA, by providing detailed information on corona…
REVIEW OF RETROSPECTIVE DOSIMETRY TECHNIQUES FOR EXTERNAL IONISING RADIATION EXPOSURES
2011
The current focus on networking and mutual assistance in the management of radiation accidents or incidents has demonstrated the importance of a joined-up approach in physical and biological dosimetry. To this end, the European Radiation Dosimetry Working Group 10 on 'Retrospective Dosimetry' has been set up by individuals from a wide range of disciplines across Europe. Here, established and emerging dosimetry methods are reviewed, which can be used immediately and retrospectively following external ionising radiation exposure. Endpoints and assays include dicentrics, translocations, premature chromosome condensation, micronuclei, somatic mutations, gene expression, electron paramagnetic re…
Value of serial magnetic resonance imaging in the assessment of brain metastases volume control during stereotactic radiosurgery
2016
AIM To evaluate brain metastases volume control capabilities of stereotactic radiosurgery (SRS) through serial magnetic resonance (MR) imaging follow-up. METHODS MR examinations of 54 brain metastases in 31 patients before and after SRS were reviewed. Patients were included in this study if they had a pre-treatment MR examination and serial follow-up MR examinations at 6 wk, 9 wk, 12 wk, and 12 mo after SRS. The metastasis volume change was categorized at each follow-up as increased (> 20% of the initial volume), stable (± 20% of the initial volume) or decreased (< 20% of the initial volume). RESULTS A local tumor control with a significant (P < 0.05) volume decrease was observed in 25 meta…
Radiation exposure in CT-guided interventions.
2013
To investigate radiation exposure in computed tomography (CT)-guided interventions, to establish reference levels for exposure, and to discuss strategies for dose reduction.We analyzed 1576 consecutive CT-guided procedures in 1284 patients performed over 4.5 years, including drainage placements; biopsies of different organs; radiofrequency and microwave ablations (RFA/MWA) of liver, bone, and lung tumors; pain blockages, and vertebroplasties. Data were analyzed with respect to scanner settings, overall radiation doses, and individual doses of planning CT series, CT intervention, and control CT series.Eighty-five percent of the total radiation dose was applied during the pre- and post-interv…