Multicommutation Fourier transform infrared determination of benzene in gasoline
2004
A fully mechanized method to determine benzene in motor gasolines has been developed based on the use of Fourier transform infrared spectroscopy (FT-IR) and multicommutation. The flow network comprised a set of three-way solenoid valves and was controlled by means of a microcomputer furnished with an electronic interface and running by a software written in QUICK BASIC 4.5. The flow network and control software were designed to implement the multicommutation approach providing facilities to handle sample and reagent solutions, so that, sample dilution, external calibration and standard addition could be easily performed on-line. The method permits the direct determination of benzene without…
Determination of Concentration Profiles of Methyl Mercury Compounds in Surface Waters of Polar and other Remote Oceans by GC-AFD
1998
Abstract The concentration of monomethyl mercury (MeHg+) and dimethyl mercury (Me2Hg) was determined in surface sea-water samples of the Antarctic and Arctic Ocean as well as of other remote areas (South Atlantic and South Pacific) during expeditions of the German research vessel “Polarstern”. A purge and trap/gas chromatographic system, equipped with an atomic fluorescence detector (AFD), was used. For the analysis of MeHg+ conversion into the volatile methylethyl mercury by reaction with tetraethyloborate prior to the purging process was carried out. The detection limit for both methylated mercury compounds was 5 pg Hg/L, which allowed their determination in most ocean water samples even …
Atomic absorption spectrometric determination of molybdenum in lubricating oils with use of emulsions
1985
Abstract Samples (0.1 g) containing molybdenum disulphide are digested with aqua regia or with a (1 + 1) hydrofluoric/nitric acid mixture, without complete destruction of the matrix, and the molybdenum is determined in an air/acetylene flame, after emulsification with a non-ionic surfactant (Nemol K-39). The detection limit is ca. 30 μg Mo g−1, and the r.s.d. is 2.9% for 6 analyses of a sample containing 6.5 mg Mo g−1.
On-line microwave oven digestion flame atomic absorption analysis of solid samples
1990
Abstract A manifold has been developed for on-line microwave oven digestion and flame atomic absorption spectrometric (FAAS) determination of metallic elements in solid samples. The use of a closed flow system permits sample treatment before analysis by FAAS, the direct injection of slurries avoids a filtration step and the interconnection of two conventional rotary injection valves allows the rapid introduction of samples and standards. The determination of lead in sewage sludge was employed as a test system for the proposed on-line sample digestion manifold. The procedure has a limit of detection of 0.2 μg Pb g−1.
A comparative study of flame atomic-absorption methods for determination of zinc in serum and blood plasma
1983
Seven selected methods for determination of zinc in blood plasma by flame atomic-absorption spectroscopy have been compared. Analytical characteristics such as sensitivity, detection limit, precision, analytical recovery, accuracy and physical interferences were studied. Two of the seven methods are recommended as the most suitable for the purpose.
Vibrational Spectrometry Strategies for Quality Control of Procymidone in Pesticide Formulations
2005
Abstract Two vibrational spectrometry–based methodologies were developed for procymidone determination in wettable powdered pesticide formulations. The Fourier‐transform infrared (FTIR) procedure was based on the selective extraction of procymidone by chloroform and determination by peak area measurement between 1451 and 1441 cm−1, using a baseline correction established between 1490 and 1410 cm−1, and a precision of 0.4% and a limit of detection of 0.01% w/w procymidone for a sample mass of 25 mg were obtained. For FT‐Raman determination, the selected conditions were peak area measurement between 1005 and 995 cm−1 Raman shift, with a baseline correction fixed between 1030 and 947 cm−1, and…
Interaction of diazepam with surfactants. Spectrophotometric and spectrofluorometric study
1986
Abstract The interaction of diazepam with non-ionic, anionic and cationic surfactants has been studied spectrophotometrically and fluorometrically. It has been verified that the absorption spectrum of diazepam is not modified in micellar medium. However, a dramatic five-fold increase in fluorescence sensitivity is observed in the presence of sodium lauryl sulphate (SDS). The experimental conditions, temperature, pH and surfactant concentration have been optimized to improve the fluorometric determination of diazepam and a detection limit of 0,04 ppmhas been obtained.
Direct determination of benzene in gasoline by flow-injection Fourier transform infrared spectrometry
1993
Abstract A Fourier transform infrared spectrometric procedure for the automated determination of benzene in gasoline was developed, based on the use of flow-injection analysis. The method permits the direct determination of benzene without any pretreatment of samples, with a limit of detection of 0.02% (v/v) and a relative standard deviation of ca. 1% [for five independent analyses of a diluted sample containing a 0.4% (v/v) of benzene]. Results found by direct analysis agreed with those obtained by off-line and on-line standard addition methods. A rapid quality control procedure was developed, based on the on-line injection of gasoline samples (diluted 1 + 9 in hexane) into a carrier strea…
Spectrophotometric estimation of bicalutamide in tablets
2007
A simple, sensitive, rapid, accurate and precise spectrophotometric method has been developed for the estimation of bicalutamide in bulk and pharmaceutical dosage forms. Bicalutamide shows maximum absorbance at 272 nm with molar absorptivity of 2.3399×10(4) l/mol/cm. Beer's law was obeyed in the concentration range of 1.5-18 μg/ml. The limit of detection and limit of quantification were found to be 0.1 and 0.4 μg/ml, respectively. Results of analysis were validated statistically and by recovery studies.
Direct determination of lead in human milk by electrothermal atomic absorption spectrometry
1999
Abstract Infants are particularly sensitive to the toxic effects of lead. Since milk is their only or main food it is important to know the contribution of milk to lead intake. The purpose of this study was to develop a direct method for determining the lead content of human milk by electrothermal atomic absorption spectrometry when a deuterium lamp is the only background correction available. The optimum conditions for lead determination in breast milk: sample dilution in Triton ×-100, modifier (75 μg of palladium) and nitric acid contents (2%) and the graphite furnace program (mineralization: 1100°C; atomization: 2300°C) were selected. The analytical parameters are: linearity (20–300 ng m…