Search results for " Standard deviation"

showing 10 items of 79 documents

Vanadium and molybdenum concentrations in particulate from Palermo (Italy): analytical methods using voltammetry

2014

The main purpose of this work was to develop a reliable method for the determination of vanadium (V) and molybdenum (Mo) in atmosphere particles or aerosols because they can not be readily measured using conventional techniques. For this research, 30 particulate samples were collected from five different stations located at Palermo, Italy. We used the catalytic adsorptive stripping voltammetry and differential pulsed voltammetry to measure Vand Mo in atmospheric particulate, respectively. The represented method includes advantages of high sensitivity, high selectivity, simplicity, reproducibility, speed and low costs. The quantification limits for V and Mo are, respectively, 0.57 and 0.80 n…

Detection limitReproducibilityRelative standard deviationAnalytical chemistrychemistry.chemical_elementVanadiumParticulatesSettore CHIM/12 - Chimica Dell'Ambiente E Dei Beni CulturalichemistryMolybdenumEnvironmental chemistryvanadium molybdenum particulate voltammetry PalermoAdsorptive stripping voltammetrySettore CHIM/01 - Chimica AnaliticaVoltammetryGeneral Environmental Science
researchProduct

Multi-pumping mechanised determination of selenium in natural waters by light emitting diode (LED) spectrometry

2009

It has been developed a fully mechanised procedure for the determination of selenium in waters employing a LED based spectrometer and solenoid multi-pumps as solution propelling devices. The proposed method is based on the reaction of selenium with potassium iodide in an acidic medium to liberate iodine, which oxidizes Variamine Blue to form a violet-colour species which absorb at 530 nm. The system was mechanised using the multicommutation process and a stopped flow strategy in the final step reaction. The analytical curve was linear between 0.010 and 0.500 mg L-1, with an equation ΔA = 0.501 (± 0.004) C and r = 0.999. The limit of detection (3σ/S) obtained for the proposed method was 0.00…

Detection limitSpectrometerNatural waterwaterRelative standard deviationLED-photometryAnalytical chemistrychemistry.chemical_elementmulti-pumpingGeneral ChemistryMass spectrometryIodinemechanised flow systemlaw.inventionchemistrylawmulticommuted flow systemseleniumSeleniumLight-emitting diodeJournal of the Brazilian Chemical Society
researchProduct

Analysis of insoluble silicate: Decomposition with molten sodium hydroxide and determination of Zr(IV) with chloranilic acid in medium-strong acid

1983

A rapid, accurate and precise method for the determination of zirconium in silicates is proposed. Insoluble or sparingly soluble samples are decomposed by means of molten sodium hydroxide. Chloranilic acid is employed as reagent for the spectrophotometric determination of Zr(IV). The limit of detection is 1.2×10−7 M and the relative standard deviation is 0.24%.

Detection limitZirconiumClinical BiochemistryRelative standard deviationInorganic chemistrychemistry.chemical_elementGeneral MedicineDecompositionSilicateAnalytical Chemistrychemistry.chemical_compoundchemistryChloranilic acidSodium hydroxideReagentGeneral Materials ScienceFresenius' Zeitschrift für analytische Chemie
researchProduct

Determination of As, Sb, Se, Te and Bi in milk by slurry sampling hydride generation atomic fluorescence spectrometry

2003

A simple and fast analytical procedure has been developed for the determination of As, Sb, Se, Te and Bi in milk samples by hydride generation atomic fluorescence spectrometry (HG-AFS). Samples were treated with aqua regia for 10min in an ultrasound water bath and pre-reduced with KBr for total Se and Te determination or with KI and ascorbic acid for total As and Sb, the determination of Bi being possible in all with or without pre-reduction. Slurries of samples, in the presence of antifoam A, were treated with NaBH(4) in HCl medium to obtain the corresponding hydrides, and AFS measurements were processed in front of external calibrations prepared and measured in the same way as samples. Re…

Detection limitchemistry.chemical_compoundchemistryHydrideRelative standard deviationSlurryAnalytical chemistryAqua regiaChemical elementAscorbic acidAtomic fluorescence spectrometryAnalytical ChemistryTalanta
researchProduct

Speciation of chromium in natural waters by micropumping multicommutated light emitting diode photometry.

2007

Abstract A simple and sensitive multicommutated flow procedure, implemented by employing a homemade light emitting diode (LED) based photometer, has been developed for the determination of chromium (VI) and total chromium in water. The flow system comprised a set of four solenoid micro-pumps, which were assembled to work as fluid propelling and as commutating devices. The core of the detection unit comprised a green LED source, a photodiode and a homemade flow cell of 100 mm length and 2 mm inner diameter. The photometric procedure for the speciation of chromium in natural waters was based on the reaction of Cr (VI) with 1,5-diphenylcarbazide. Cr (III) was previously oxidized to Cr (VI) and…

Detection limitmedicine.diagnostic_testChemistryNatural waterRelative standard deviationAnalytical chemistrychemistry.chemical_elementAnalytical Chemistrylaw.inventionPhotometry (optics)ChromiumlawSpectrophotometrymedicineInner diameterLight-emitting diodeTalanta
researchProduct

Calcification is not the Achilles'heel of cold-water corals in an acidifying ocean

2015

Ocean acidification is thought to be a major threat to coral reefs: laboratory evidence and CO2 seep research has shown adverse effects on many coral species, although a few are resilient. There are concerns that cold-water corals are even more vulnerable as they live in areas where aragonite saturation (Omega ara) is lower than in the tropics and is falling rapidly due to CO2 emissions. Here, we provide laboratory evidence that net (gross calcification minus dissolution) and gross calcification rates of three common cold-water corals, Caryophyllia smithii, Dendrophyllia cornigera, and Desmophyllum dianthus, are not affected by pCO2 levels expected for 2100 (pCO2 1058 µatm, Omega ara 1.29),…

Dissolution rateOcean Acidification International Coordination Centre (OA-ICC)TemperateIdentificationSalinityBicarbonate ion standard deviationinorganicAlkalinity total standard deviationAlkalinityExperimentTemperature waterCarbon inorganic dissolvedCalculated using seacarb after Nisumaa et al 2010Aragonite saturation stateRespiration rate oxygenAlkalinity totaltotalDesmophyllum dianthuspHRespirationTemperatureCalcification rate of calcium carbonatedissolvedLaboratory experimentCarbonate ionDeep seaPartial pressure of carbon dioxide (water) at sea surface temperature (wet air)Field experimentCarbon dioxide standard deviationTemperature water standard deviationContainers and aquaria 20 1000 L or 1 m 2Respiration rateEarth System ResearchContainers and aquaria (20-1000 L or &lt; 1 m**2)standard deviationCalcification/DissolutionPotentiometric titrationCalcite saturation statePotentiometricwaterPartial pressure of carbon dioxideCaryophyllia smithiiContainers and aquaria (20-1000 L or < 1 m**2)Dendrophyllia cornigeraFigureAragonite saturation state standard deviationBenthosCnidariaOcean Acidification International Coordination Centre OA ICCMediterranean SeaAnimaliaBicarbonate ionCalculated using seacarb after Nisumaa et al. (2010)SpeciesCalculated using CO2SYSfungiEvent labelDeep-seaPartial pressure of carbon dioxide standard deviationCarbonate system computation flagpH standard deviationCarbonate ion standard deviationbiochemical phenomena metabolism and nutritionFugacity of carbon dioxide (water) at sea surface temperature (wet air)CarbonTreatmentPartial pressure of carbon dioxide water at sea surface temperature wet airCarbon dioxideSingle speciesCalcification DissolutionFugacity of carbon dioxide water at sea surface temperature wet airBenthic animalsoxygen
researchProduct

Variations in Substitution Rate in Human and Mouse Genomes

2003

We present a method to quantify spatial fluctuations of the substitution rate on different length scales throughout genomes of eukaryotes. The fluctuations on large length scales are found to be predominantly a consequence of a coarse-graining effect of fluctuations on shorter length scales. This is verified for both the mouse and the human genome. We also found that both species show similar standard deviation of fluctuations even though their mean substitution rate differs by a factor of two. Our method furthermore allows to determine time-resolved substitution rate maps from which we can compute auto-correlation functions in order to quantify how fast the spatial fluctuations in substitu…

Genomics (q-bio.GN)GenomeModels GeneticGenome HumanRelative standard deviationSubstitution (logic)AutocorrelationPopulations and Evolution (q-bio.PE)Genetic VariationGeneral Physics and AstronomyGenomicsTime resolutionBiologyQuantitative Biology::GenomicsGenomeMiceEvolutionary biologyFOS: Biological sciencesAnimalsHumansQuantitative Biology - GenomicsHuman genomeQuantitative Biology - Populations and EvolutionRepetitive Sequences Nucleic Acid
researchProduct

Molecular hydrogen (H2) mixing ratio and stable isotopic composition (dD) at the Cabauw tall tower in the Netherlands (2008-2012)

2016

Measurements of the stable isotopic composition (dD(H2) or dD) of atmospheric molecular hydrogen (H2) are a useful addition to mixing ratio (X(H2)) measurements for understanding the atmospheric H2 cycle. dD datasets published so far consist mostly of observations at background locations. We complement these with observations from the Cabauw tall tower at the CESAR site, situated in a densely populated region of the Netherlands. Our measurements show a large anthropogenic influence on the local H2 cycle, with frequently occurring pollution events that are characterized by X(H2) values that reach up to 1 ppm and low dD values. An isotopic source signature analysis yields an apparent source s…

HEIGHT above groundDATE/TIMEIdentificationδ DeuteriumMonitoring stationDATE TIMEEarth System Researchδ Deuterium standard deviationSample commentHydrogen mixing ratio standard deviationstandard deviationHydrogen mixing ratioQuality code
researchProduct

(Supplement Table S2) Results of 230Th/U-dating

2016

We compared the suitability of two skeletal materials of the Atlantic brain coral Diploria strigosa for 230Th/U-dating: the commonly used bulk material comprising all skeletal elements and the denser theca wall material. Eight fossil corals of presumably Last Interglacial age from Bonaire, southern Caribbean Sea, were investigated, and several sub-samples were dated from each coral. For four corals, both the ages and the activity ratios of the bulk material and theca wall agree within uncertainty. Three corals show significantly older ages for their bulk material than for their theca wall material as well as substantially elevated 232Th content and (230Th/238U) ratios. The bulk material sam…

Hand drillUranium 238Thorium 230 Uranium 238 activity ratioThorium-230/Uranium-238 activity ratioUranium-238Thorium-230/Uranium-238 activity ratio standard deviationAGECenter for Marine Environmental Sciences MARUMMulti collector inductively coupled plasma mass spectrometer MC ICP MSCenter for Marine Environmental Sciences (MARUM)Thorium 232Thorium 232 Uranium 238 activity ratioThorium-232/Uranium-238 activity ratio standard deviationEvent labelCommentUranium 234 Uranium 238 activity ratioUranium-234/Uranium-238 activity ratioDrilling/drill rigAge 230Th/U Thorium-UraniumAge standard deviationDrilling drill rigThorium-232/Uranium-238 activity ratioUranium-234/Uranium-238 activity ratio standard deviationThorium-232230Th U Thorium UraniumEarth System ResearchGroupMulti-collector inductively coupled plasma mass spectrometer (MC-ICP-MS)standard deviation
researchProduct

Occurrence of fumonisins in organic and conventional cereal-based products commercialized in France, Germany and Spain

2013

A fast and effective method for quantitative determination of fumonisins B1 and B2 (FB1 and FB2) in different cereal-based products was developed. Fumonisins were extracted combining a solid liquid extraction (SLE) pre-treatment and immunoaffinity columns (IACs), which were applied for an effective clean-up. Consecutively, high pressure liquid chromatography (HPLC) coupled to hybrid triple quadrupole-linear ion trap mass spectrometer (QTrap®) was used for the separation, detection and quantification of targeted mycotoxins. The analytical method showed acceptable recoveries ranged from 89.7% to 99.1%, as well as a relative standard deviation (%, RSD) lower than 12%. A total of 1250 samples f…

IAC columnsRelative standard deviationFood ContaminationToxicologyHigh-performance liquid chromatographyFumonisinschemistry.chemical_compoundTandem Mass SpectrometryGermanyMycotoxinSolid liquidChromatography High Pressure LiquidFumonisin B1ChromatographyChemistryExtraction (chemistry)Reproducibility of ResultsGeneral MedicineMycotoxinsQuantitative determinationSpainFood MicrobiologyCereal-based productsIon trapFranceEdible GrainQTrapFood ScienceFood and Chemical Toxicology
researchProduct