Search results for " Thickness"
showing 10 items of 285 documents
Orbscan Pachymetry: Differences between observers when carrying out measurements of the corneal thickness
2005
espanolObjetivo: Estudiar el espesor corneal y la variabilidad entre observadores de las mediciones del espesor corneal empleando paquimetria Orbscan. Metodos: Analizamos el espesor corneal central y paracentral de 30 sujetos (n=30) cuya edad oscilaba entre 19 y 38 anos (media 27,27 D.E. 5,25) con el Sistema Topografico Orbscan II (Orbscan, Inc., Salt Lake City, UT, USA). La media de cinco mediciones consecutivas del espesor corneal fue obtenida por dos diferentes observadores. Los resultados obtenidos por los dos observadores se compararon. Resultados: No se encontraron diferencias significativas entre los valores medios del espesor corneal de los observadores en la cornea central (p=0,749…
On the theory of domain structure in ferromagnetic phase of diluted magnetic semiconductors
2006
Abstract We present a comprehensive analysis of domain structure formation in ferromagnetic phase of diluted magnetic semiconductors (DMS) of p-type. Our analysis is carried out on the base of effective magnetic free energy of DMS calculated by us earlier [Yu.G. Semenov, V.A. Stephanovich, Phys. Rev. B 67 (2003) 195203]. This free energy, substituting DMS (a disordered magnet) by effective ordered substance, permits to apply the standard phenomenological approach to domain structure calculation. Using coupled system of Maxwell equations with those obtained by minimization of above free energy functional, we show the existence of critical ratio ν cr of concentration of charge carriers and ma…
Electrochemical impedance spectroscopy as a tool to estimate thickness in PB films
2006
The analysis of the faradaic impedance of electroactive films provides a characteristic point from which it is possible to estimate the thickness of thin films. Thus, electrochemical impedance spectroscopy was used in this paper as a fast and easy technique to estimate this thickness. The proposed method was checked on PB films. Keywords: Prussian blue, Electrochemical impedance spectroscopy, Thickness
Comparison of histological and computed tomographic measurements of pig lung bronchi.
2020
Aim Light microscopy is used as template in the evaluation and further development of medical imaging methods. Tissue shrinkage caused by histological processing is known to influence lung tissue dimensions. In diagnosis of COPD, computed tomography (CT) is widely used for automated airway measurement. The aim of this study was to compare histological and computed tomographic measurements of pig lung bronchi. Methods Airway measurements of pig lungs were performed after freezing under controlled inflation pressure in a liquid nitrogen bath. The wall thickness of seven bronchi was measured via Micro-CT and CT using the integral-based method (IBM) and the full-width-at-half-maximum method (FW…
Publisher Correction: X-Ray Nanotomography of Individual Pulp Fibre Bonds Reveals the Effect of Wall Thickness on Contact Area
2020
Fibre bonds play an essential role in various properties of paper. Much research has focused on their strength, but the determination of the actual contact area also provides a challenge. Many of the research methods rely on optical tools, which are restricted by the wavelength of light that is utilised. Novel X-ray computed tomography devices utilise X-rays in studying the inner structure of materials, and surpass the optical methods in terms of resolution, allowing detection of even smaller details and variations in distance between the fibres in the bond intersection area. X-ray nanotomography was used to image 26 individual cellulose fibre bonds made of springwood and summerwood fibres …
Measuring intrinsic thickness of rough membranes: application to nanofibrillated cellulose films
2015
Adequate measurement of thickness of sheet-like materials or membranes is most important for quantifying their properties such as density, barrier properties and mechanical strength. Depending on the surface roughness of the membrane, the thickness measured by standard micrometre devices (apparent thickness) may considerably overestimate the actual geometrical mean thickness (intrinsic thickness) required for such purposes. In this work, we present a method for correcting the measured apparent thickness value of thin membranes for their surface roughness, thereby obtaining an improved estimate of the intrinsic thickness. The surface roughness data required for the correction can be obtained…
Raman Spectroscopy and Low-Temperature Transport Measurements of Individual Single-Walled Carbon Nanotubes with Varying Thickness
2009
We have investigated two metallic and one semiconducting individual single-walled carbon nanotubes (SWNT) and one bundle of two semiconducting nanotubes with a diameter range 1.1−2.9 nm with Raman spectroscopy and low-temperature electric transport measurements. With these two methods, we obtain mutually independent measurements on the basic properties of a specific nanotube. In particular, we obtain data on metallic and semiconducting properties. Evidence of a small band gap for one metallic tube was obtained. For the semiconducting SWNTs with diameters of 2.7−2.9 nm, a special resonance condition was observed which causes an anomalous intensity ratio for the two components of the G-band. …
Photoelectrochemical Synthesis of Polypyrrole on Anodic Ta2O5 Films
2007
Polypyrrole film was photoelectrochemically grown on insulating Ta2O5 anodic film in acetonitrile solution. A characterization by photocurrent spectroscopy PCS of metal/oxide/polypyrrole interface was carried out. The PCS results suggest that a metallic-like PPy is formed under illumination at constant anodic potential. By polarizing the polypyrrole at cathodic potentials a photocurrent spectrum typical of p-type semiconducting film was recorded. A scanning electron microscopy study of PPy surfaces solution side and oxide side allowed us to obtain information on the morphology of the polymer as well as a rough estimate of the film thickness and of the diameter of PPy globules at the two int…
Poly-left-lactic acid tubular scaffolds via diffusion induced phase separation: Control of morphology
2013
n this work, tubular poly-left-lactic acid scaffolds for vascular tissue engineering applications were produced by an innovative two-step method. The scaffolds were obtained by performing a dip-coating around a nylon fiber, followed by a diffusion induced phase separation process. Morphological analysis revealed that the internal lumen of the as-obtained scaffold is equal to the diameter of the fiber utilized; the internal surface is homogeneous with micropores 1–2 μm large. Moreover, a porous open structure was detected across the thickness of the walls of the scaffold. An accurate analysis of the preparation process revealed that it is possible to tune up the morphology of the scaffold (w…
Constant Heat Input Friction Stir Welding of Variable Thickness AZ31 Sheets Through In-Process Tool Rotation Control
2019
Tailored blanks characterized by variable thickness were friction stir welded (FSWed) with the aim to obtain constant joint properties along the weld seam, regardless of the thickness change. To pursue this goal, the heat input was kept constant by in-process control of tool rotation. A dedicated numerical model of the process was used to determine the tool rotation values as a function of the sheet thickness. The mechanical properties and the microstructure of the FSWed joints, produced with varying process parameters, were studied. It was found that the proposed approach can produce joints with uniform properties along the weld line in terms of stress–strain curve shape, joint strength, e…